Gem 54 Regency Gas Fire
33
installation
WIRING DIAGRAM
HIGH
OFF
LOW
Red
Black
Yellow/Green
Ground
Brown
(Live)
White
White
Bl
ac
k
Blue
(Neutral)
Fan Thermodisc
(Normally open)
Ground
Fan
Fan
240 V AC
50 HZ
909-185
Part #: 909-185
Colour: Black on White.
Size: 2” x 3”
Oct. 07/10
Requested by Dave Lal
AERATION ADJUSTMENT
The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close
for a more yellow flame.
Minimum Air Shutter Opening:
NG 13mm
LP Full open 22 mm
ULPG Full open 22mm
CAUTION:
Carbon will be produced if air shutter
is not fully open.
CAUTION
: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.