Gem 54 Regency Gas Fire
23
installation
Vertical Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V+ V1
With these options,
max. total pipe length
is 9m with min. of
2.7m total vertical
and max. 2.4m total
horizontal.
A)
.6m Min.
.6m Max.
1.2m Min.
B)
.9m Min.
1.2m Max.
1.8m Min
C)
1.2m Min.
1.5m Max.
2.1m Min.
D)
1.5m Min.
1.8m Max.
2.4m Min.
E)
1.8m Min.
2.4m Max.
2.7m Min.
Please note minimum .3m between 90
o
elbows is required.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment required.