Gem 54 Regency Gas Fire
51
maintenance
ON/OFF Connector Wires
8)
Disconnect the ON/OFF connector wires from the valve.
11)
Remove the valve tray by undoing 12 screws.
12)
Slightly lift out valve tray.
13)
Disconnect the inlet gas line.
14)
Replace valve and reverse steps.
7)
Remove bottom cover by undoing 3 screws securing it to the firebox
base, lift up and out.
Aerial View of the inside of the unit shown.
9)
Disconnect the DC Sparker leads at the valve.
10)
Unplug the Ignitor wire from the DC Sparker.
DC Sparker Lead
Ignitor Wire