66
|
City Series
installation
LP conversion instructions
CV40E/ CB40E using SIT 885 NOVA Gas Valve
Caution: The gas supply shall be shut off prior to disconnecting the
electrical power, before proceeding with the conversion.
Always let the appliance cool to room temperature before servicing.
1. Remove the outer panels and safety glass — see manual.
2. Remove inner ceramic glass — see manual.
3. Remove inner panels — see manual.
4. Remove all media installed on burner (glass, logs or stones, etc).
5. Disconnect the Cable coming from the Pressure Regulator Motor.
6. If unable to access this Cable - undo 2 screws securing the IFC Board
and slide out of unit to access cable.
WARNING
This conversion kit shall be installed by a qualifi ed
service agency in accordance with the manufac-
turer’s instructions and all applicable codes and
requirements of the authority having jurisdiction.
If these instructions is not followed exactly, a fi re,
explosion or production of carbon monoxide may
result causing property damage, personal injury
or loss of life. The qualifi ed service agency is re-
sponsible for the proper installation of this kit. The
installation is not proper and complete until the
operation of the converted appliance is checked as
specifi ed in the manufacturer’s instructions sup-
plied with the kit.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!
Cable from motor
Conversion Kit 656-969 includes:
1
911-191
Stepper Motor LP for 885 SIT
1
904-947
Orifi ce #53
1
910-101
Pilot Orifi ce #35
1
918-590
Decal - Conversion to LP
1
908-528
Label Propane
1
904-529
5/32" long Allen Key
7. Remove and discard 2 Pressure regulator screws (A)using a (T20 or slot
screwdriver,) Pressure Regulator (B) and Spring and Diaphragm (C)
(see below).
8. Ensure the rubber gasket, which is prefi tted as part of the Assembly,
is properly positioned. Install the new Pressure Regulator using the 2x
M4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event that
the screw threads are cross threaded or stripped, replace the valve as-
sembly.
Install the enclosed propane identifi cation label to the valve body where it
can be easily seen.
Pressure
regulator
screws
9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re-
situate the IFC, secure the screws that fasten the IFC Mounting Brackets.
10. Remove pilot hood by lifting up and off.
Содержание City Series CB40E-LP
Страница 86: ...86 City Series parts list 7 8 9 2 1 3 6 4 5 12 17 27 19 20 18 22 6a 26 24 23 25 11 ...
Страница 89: ...City Series 89 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...
Страница 90: ...90 City Series notes ...
Страница 95: ......
Страница 96: ...96 City Series notes ...
Страница 97: ...City Series 97 notes ...
Страница 98: ...98 City Series notes ...
Страница 99: ......