City Series
installation
Vertical Termination 4" x 6-7/8" venting
Diagram 1: The upper half of the l ashing is
installed under the rooi ng material and not
nailed down until the chimney is installed.
This allows for small adjustments.
1.
Maintain the 1-½” clearance (air space) to combustibles when passing
through ceilings, walls, l oors, enclosures, attic rafters or other nearby
combustibles. Do not pack air spaces with insulation. Check Venting
sections for the maximum vertical rise of the venting system and the
maximum horizontal of set limitations.
Ensure that you maintain clearances around enclosures, walls, below
or above l oors, l oor joists, etc. Each appliance has dif erent clearance
requirements (top,sides,bottom). See specii c appliance manual for details.
2.
Set the appliance in its desired position. Drop a plumb bob down from
the ceiling/l oor joist to the position of the appliance l ue exit and mark
the location where the vent will penetrate the ceiling. Drill a small hole
at this point. Next drop a plumb bob from the roof to the hole previously
drilled at the ceiling level and mark the spot where the vent will penetrate
the roof.
6
.
Determine the overall height of the chimney from the top of the appliance
to the underside of the l ashing. If required cut the l exible inner and outer
pipe to the desired length up to a maximum of 20 feet.
7. Put a bead of Mill-Pac around the 4 inch collar on the appliance and slide
the inner l ex pipe over the inner collar of the appliance and secure with
a minimum of 3 screws.
8. Install 4 inch spacers around 4 inch l ex.
9. Repeat Step 7 to install the outer pipe to the outer collar of the appliance
Note:
If an of set is necessary in the attic or l oor joists it is important to
support the vent pipe every 3 feet to avoid excessive stress and
sagging of the vent pipe. Wall straps are provided (3 in total) for this
purpose. All round/plumbers strapping may also be used if further
supports are required.
10. Attach the rigid pipe section to the adaptor by using Mill-Pac on the inner/
outer pipe. Use 3 screws to secure outer pipe.
3
.
Cut a hole in the roof centered on the small hole placed in the roof in the
previous steps. The hole should be a minimum of 10-¼ inches. The hole
may be round and or square.
4.
Slip the l ashing under the shingles and line up l ashing so it is centered
to the hole (shingles should overlap half of the l ashing) as per Diagram
1.
4" X 6-7/8" VENTING - VERTICAL FLEX VENT KIT (946-755)
11. Secure inner l ex pipe to pipe adaptor by using Mill-Pac over the adaptor.
Slide the inner pipe over adaptor and secure with 3 screws.
12. Repeat Step 11 to secure outer l ex.
Diagram 4
14. Put a bead of caulking on the exterior between the outer pipe and l ashing
to prevent water from penetrating the chimney system.
15. Slide storm collar over pipe length until it reaches the l ashing.
16. Install termination cap by twist locking it.
17. Secure the l ashing to the roof using screws
Note
: Any closets or storage spaces which the vent passes through must
be enclosed.
Roof Pitch Minimum Vent Height
Feet Meters
l at to 7/12
2
0.61
over 7/12 to 8/12
2
0.61
over 8/12 to 9/12
2
0.61
over 9/12 to 10/12
2.5
0.76
over 10/12 to 11/12
3.25
0.99
over 11/12 to 12/12
4
1.22
over 12/12 to 14/12
5
1.52
over 14/12 to 16/12
6
1.83
over 16/12 to 18/12
7
2.13
over 18/12 to 20/12
7.5
2.29
over 20/12 to 21/12
8
2.44
Diagram 3
Diagram 3a
Diagram 3b
13. Slide the i nished length up towards the l ashing ensuring the length of
pipe is a minimum of 2 feet measured from the top of the roof. Level the
chimney and secure using the roof support provided with kit to bottom
side of the roof as shown using a minimum of 2 screws per side- see
Diagram 3b. See Diagram 4 for roof pitch and height requirements. See
Diagram 3a for securing method if 2 ft. is insuffi cient and additional lengths
are required, this may be purchased separately. See Simpson Duravent
components list in the instruction manual for part numbers.
Flex Pipe
Ceiling Firestop
Roof Support / Brace
Flashing
Storm Collar
Termination Cap
Ceiling Firestop
Enclosure
Flex Pipe
Ceiling Firestop
Roof Support
Flashing
Elbow Support
Termination Cap
Storm Collar
Ceiling Firestop
Support to prevent sagging
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
60
-1/4
Ceiling firestop
Diagram 2
Diagram 2a
Diagram 1
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
Firestop spacer to prevent
debris from falling into the
ceiling i restop
5. A ceiling i restop/i restop spacer must be installed when passing through
each l oor or ceiling level. To install the ceiling i restop/i restop spacer in
a l at ceiling or l oor joist cut a 10- ¼ inch square hole. Frame the hole
as show in Diagram 1 and install the ceiling i restop. Slide the top attic
insulation spacer onto the top of the attic insulation shield/i restop - See
Diagram 1a. Secure with 4 screws/nails. If more than one is required,
these can be purchased separately.
Note:
The ceiling i restop/i restop spacer may be cut down to size if this
shield is too high for the application.
Содержание City Series CB40E-LP
Страница 86: ...86 City Series parts list 7 8 9 2 1 3 6 4 5 12 17 27 19 20 18 22 6a 26 24 23 25 11 ...
Страница 89: ...City Series 89 parts list 16 12 22 21 18 20 19 9 26 25 8 11 26 16 16 6 23 5A 27 17 16 ...
Страница 90: ...90 City Series notes ...
Страница 95: ......
Страница 96: ...96 City Series notes ...
Страница 97: ...City Series 97 notes ...
Страница 98: ...98 City Series notes ...
Страница 99: ......