60
| City Series CC40EPV
installation
920-040
02.13.19
2
CITY SERIES
15. Reinstall pilot cap and pilot retainer clip.
16. Prior to installing burner—adjust aerations settings - to 1/4" for
LP.(CB40E/CC40E/CV40E/CB40EPV/CV40EPV/CC40EPV) or 3/8"
(CB40E-1/CC40E-1/CV40E-1) Reinstall burner (see Step 13).
17. Ensure the pilot light is in the correct orientation to the Burner. Recon-
nect the gas and electrical supply to the appliance. Start the appliance.
(see section on Lighting Instructions) Ensure that pilot and burner igni-
tion is completed without delay. Check both your inlet and outlet pres-
sures at full load. With a soapy solution, leak test the entire system.
Verify both the correct flame and pilot appearance.
18. See Gas Pipe Pressure Testing in manual.
13. Remove pilot retainer clip with pliers and pull off the pilot cap to expose
the pilot orifice.
14. Unscrew the pilot orifice with the allen key; then replace with the LPG
pilot orifice and the pilot cap, provided in the kit.
Installer Notice:
These instructions must be left
with the appliance
.
Pilot retainer clip
12. Remove burner orifice with a 3/8" wrench. Use another wrench to hold
on to the elbow behind the orifice. Discard orifice. Reinstall new burner
orifice LPG stamped #53 and tighten.
Burner Orifice
Location
CV40E shown
11. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide
burner to the left away from the orifice and lift out.
front
screw locations
back screw locations
City Series
LP SYSTEM DATA
Min. Supply Pressure
11" WC (2.73kpa)
Manifold Pressure - High
10.5" WC (2.62 kpa)
Manifold Pressure - Low
2.9" WC (0.72 kpa)
Orifice Size
#53 DMS
Maximum Input
28,500 Btu/h (8.35 kW)
Minimum Input
15,500 Btu/h (4.54 KW)
Altitude
0-4500 ft (0-1372m)
Содержание City CC40LEPV-LP
Страница 84: ...84 City Series CC40EPV ...
Страница 85: ...City Series CC40EPV 85 notes ...
Страница 86: ...86 City Series CC40EPV notes ...
Страница 87: ......