54
| City Series CC40EPV
installation
This appliance is equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly grounded three-
prong receptacle. Do not cut or remove the grounding prong from this plug.
Wiring Diagram
Caution: Ensure that the wires do not
touch any hot surfaces and are away from
sharp edges.
CAUTION: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
No electrical power supply is required for the gas
control to operate. 120 Volt AC power is needed
for the lights. A receptacle box, receptacle and
cover are provided and located on the left hand
side of the unit, under the outer base panel.
Electrical power must be brought to the
appliance by a licensed electrician.
(Do not cut the ground terminal off under any
circumstances.)
BLACK
BA
TTER
Y
HOLDER
BATTERY
CONNECTION
VARIABLE
LIGHTS
WHITE
YELL
OW
TWIST-ON WIRE
CONNECTORS
YELL
OW
TO GROUND
COPPER LINE
TO GROUND
FAN MOTOR
POWER VENT CAP
WHITE
WHITE
BLUE
BLA
CK
BLA
CK
BLA
CK
WHITE
RED (
COM)
RED
BL
UE
BL
UE (NO
)
RED
BLUE
RED
BL
UE
RED
ANTI-SHORT
BUSHING
Electrical Shielding Box
ARMOURED
CABLE
COPPER LINE
TO GR
OUND
PRESSURE SWITCH