City Series CC40EPV
| 5
safety decal
This is a copy of the label that accompanies Direct Vent Gas
Fireplace. We have printed a copy of the contents here for your
review. The safety label is located on the front inside base of
the unit, visible when the outer front panel is removed.
NOTE: Regency
®
units are constantly being improved. Check
the label on the unit and if there is a difference, the label on
the unit is the correct one.
Copy of Safety Decal
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Part #:
919-919a
Colour:
Black on grey except what is indicated as being printed red.
Size:
(File at 100%) 9.3"w x 5.7"h
Material:
Start serial sequence @ 477000001
Oct. 10/18:
Created draft
Nov.21/18:
Added efficiencies as per R/D
Jan. 29/19:
Remodeled decal + added ETL logo at the bottom
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
477
477
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
Dégagements minimaux par rapport aux matériaux combustibles
Serial No./ No de série
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Listed/Nom:
VENTED GAS FIREPLACE / FOYER AU GAZ À ÉVACUATION
Certified to/Certifi :
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
Electrical supply / Alimentation électrique 115VAC, 1.5 A, 60Hz.
Made in Canada/ Fabriqué au Canada
Duplicate S/N
(
See instruction manual for detailed instructions)
(Voir manuel pour plus de détails)
GAZ PROPANE : Modèle
CC40LEPV-LP/CC40REPV-LP
PROPANE GAS: Model: CC40LEPV-LP/CC40REPV-LP
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
GAZ NATUREL : Modèle
CC40LEPV-NG/CC40REPV-NG
5.0" WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
# 42 DMS
28,500 Btu/h (8.33 kW)
15,500 Btu/h (4.54 kW)
0-4500 ft/pi (0-1372 m)
11" WC
(2.73 kpa)
10.5 " WC/C.E. (2.62 kPa)
2.9" WC/C.E. (0.72 kPa)
# 53 DMS
28,500 Btu/h (8.35kW)
15,500 Btu/h (4.54 kW)
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
Side Walls / Murs latéraux
A
36” (914 mm)
Ceiling / Plafond
B 37-1/2” (953 mm)
Min. Mantel Height
/Hteur Min
Manteau
C
9" (229 mm)
Max. Mantel Depth/Profondeur Max
Manteau
D
12” (305 mm)
Alcove Width/Largeur Alcôve
E
84" (1524 mm)
Alcove Depth/Profondeur Alcôve
F
36" (2134 mm)
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction
and Safety Standard. Si ces normes ne sont pas applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C
Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
For Use Only with Barrier CC40LEPV - Left Corner (Part # 940-485/P,940-440/P) & CC40REPV Right Corner (Part # 940-485/P,940-439/P) Follow installation instructions.
Utiliser uniquement avec l’écran CC40LEPV -Coin gauche (n°940-485/P,940-440/P) & CC40REPV - Coin droit (n°940-485/P,940-439/P) . Suivre les instructions d'installation.
Pression d'alimentation minimale
Pression de sortie (manifold) - Haute
Pression de sortie (manifold) - Basse
Taille de l’orifice
D bit calorifique maximal
é
D bit calorifique minimal
é
Altitude
Pression d'alimentation minimale
Pression de sortie (manifold) - Haute
Pression de sortie (manifold) - Basse
Taille de l’orifice
D bit calorifique maximal
é
D bit calorifique minimal
é
Altitude
VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
Part No. 946-556 Heatwave Kit may be used. La trousse Heatwave (pièce n°946-556) peut être utilisée
.
Model/Modèle :
CC40LEPV-NG
CC40LEPV-LP
CC40REPV-NG
CC40REPV-LP
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY À UTILISER AVEC LES PORTES VITRÉES HOMOLOGUÉES POUR L'APPAREIL
C #: 4001172
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
J
B
C
D
H
A
E
F
919-919a
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 60.02%
Propane Gas / Gaz propane 60.85%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
NATURAL GAS: Model: CC40LEPV-NG/CC40REPV-NG
Decal Location
Remove barrier glass from unit (refer to manual)
lift out the outer liner base glass once the glass
has been removed the rating plate will be attached
to a small black chain as seen below.
DO NOT REMOVE DECAL FROM UNIT
Содержание City CC40LEPV-LP
Страница 84: ...84 City Series CC40EPV ...
Страница 85: ...City Series CC40EPV 85 notes ...
Страница 86: ...86 City Series CC40EPV notes ...
Страница 87: ......