background image

Installer: Please complete the details on the back cover 
and leave this manual with the homeowner.
Homeowner:
 Please keep these instructions for future reference.

City Series

®

 

Direct Vent Gas Power Vent Fireplace

Owners & 

Installation Manual

STYLE 

                     

     MODEL    

Left Corner                            CC40LEPV-NG / CC40LEPV-LP
Right Corner                            CC40REPV-NG / CC40REPV-LP

Tested by: 

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     Warning
Fire or explosion Hazard

failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

919-925b

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

03.27.19

Certified to/Certifié pour: CSA 2.17-2017
                                            ANSI Z21.88-2017
                                            CSA 2.33-2017

Содержание City CC40LEPV-LP

Страница 1: ...t try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Wa...

Страница 2: ...ulations You are the owner of a state of the art Gas Fireplace by REGENCY The City Series are hand crafted appliances and have been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The CC40LE CC40RE City Series have been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort...

Страница 3: ...National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped with four 1 4 diameter holes located near each corner of the base Fasten the fireplace in place using screw inserted through the holes This appliance comes equ...

Страница 4: ...mation 9 Lighting Procedure 10 Shutdown Procedure 10 Copy of the Lighting Plate Instructions 11 Proflame II Remote Control Operating Instructions 12 Inner Glass Panel Firebox Glass Installation Removal 16 Outer Safety Glass Panel Barrier Glass Installation Removal 18 Outer Safety Glass Panel Barrier Glass Installation Removal 19 Maintenance Instructions 20 Log Replacement 20 Glass Gasket 20 Glass ...

Страница 5: ... MH Mobile Housing in Canada or with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or when such a standard is not applicable ANSI NCSBCSA225 1 NFPA501A Manufactured Home Installations Standard orANSI A119 2 ou NFPA501C Standard for Recreational Vehicles This appliance is only for use with the type s of gas indicated on the rating plate and may b...

Страница 6: ...Note Height Dimension may vary depending on the height of the leveling legs CC40LE Left Corner Dimensions Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when converted when greater accuracy is required use the metric dimensions Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION ...

Страница 7: ... 4 102mm 11 7 16 290mm 7 1 4 184mm 23 1 8 587mm 24 1 4 616mm 47 3 8 1203mm CC40RE Right Corner Dimensions Note Height Dimension may vary depending on the height of the leveling legs Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when converted when greater accuracy is required use the metric dimensions Note These units are non load bear...

Страница 8: ...IDUALSOUT OF THE ROOM AND AWAY FROM HOT SURFACES Important Message SAVE THESE INSTRUCTIONS City Series Direct Vent Fireplaces must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensu...

Страница 9: ...o operating the appliance 7 To prevent injury do not allow anyone who is unfamiliarwiththeoperationtousethefireplace 8 Wear gloves and safety glasses for protection while doing required maintenance 9 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 10 Under no circumstances should this appliance be modified Parts that have to be removed for servicing...

Страница 10: ...er switch to the ON position if equipped Note The first try for ignition will last approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will n...

Страница 11: ...ntenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas scrupuleusement les instructions de la présente notice risque de déclencher un incendie ou une explosion pouvant entraîner des dégâts matériels ...

Страница 12: ...itter Figure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of r...

Страница 13: ...by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The t...

Страница 14: ... The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To act...

Страница 15: ...ouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to choose a traditional continuous pilot The primary benefit of having the IPI function is a significant savings on fuel as the pilot will only run when there is a call for heat Thermostat Icon If the thermostat icon is...

Страница 16: ...Top clamps in closed position Bottom clamps in closed position Push side glass panel firmly to back wall until springs are compressed then close clamps Important Prior to installing the inner glass ensure that there is no media present in the bottom channel as this can cause damage to the glass Remove any media from bottom channel prior to installing the glass WARNING GLASS HANDLING We recommend u...

Страница 17: ...ntered with the front panel in position secure in place by closing the 3 lower clamps and 4 upper clamps Open clamps to release pressure on the springs Press glass vacuum clamps in open position firmly onto surface of glass Bring handles together to close Open Closed 7 Return to the side panel s and release the upper and lower clamps The springs will release and push the glass side panel forward s...

Страница 18: ...ss panel shown in image depicting proper handling of glass WARNING GLASS HANDLING We recommend using the glass vacuum holders supplied by the manufac turer Lower the glass to rest in a safe place this is to prevent damage to the glass edges Extra care must be taken when removing installing the glass Breakage or damage to the edge of the glass which occurs as a result of careless handling will not ...

Страница 19: ... better illustrate the install this area is not visible when installing glass 4 For 3 sided and corner units only With front panel installed proceed to install the side panel s Identify the left and right side panels before installing Facing the front of the unit the right panel will show an arrow pointing to the front of the unit as shown in the diagram below Note After the side panel has been ad...

Страница 20: ...5 P Outer Safety Glass Side Tempered Small 940 439 P Maintenance Instructions 1 Always turn off the gas valve before cleaning Forrelighting refertolightinginstructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brushasthelogsarefragileandeasilydamaged 2 Clean appliance and door with a damp cloth never w...

Страница 21: ...ine with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the i...

Страница 22: ... details 6 We recommend that you plan your installa tion on paper using exact measurements for clearances and floor protection before actually installing this appliance Have an authorized inspector dealer or installer review your plans before installation Note For vent terminations refer to Exterior Vent Termination Locations section Unit Assembly Prior to Installation Before you Start The CC40LE ...

Страница 23: ...tional features Refer to the following sections where applicable a Safety Glass b Firebox inner glass c Log Set d Fireglass e Ceramic stones or other approved media f Painted enamel or glass panels panels required g Optional Framing Kit h Heatwave Kit 8 Plug 3 prong plug for the lights into the receptacle The 3 prong plug will be located near the gas valve on the appliance 9 Final check Before lea...

Страница 24: ...te ensure that the access panel is reinstalled prior to any finishing The CC40LE CC40RE has 4 screws to remove access cover See locations in diagram to the right Side nailing strip CC40LE tooltip Side nailing strip CC40RE Top Nailing Strip CC40LE CC40RE Nailing strip is shipped with the appliance and will need to be attached Note that the nailing strips are not required if using the optional chase...

Страница 25: ...C40RE Clearance single sided Dimension Measured From A Mantel Height min Top of Fireplace Opening B Opening Height 15 1 16 382mm Bottom Top of Fireplace Opening C From Floor Min 0 Bottom of Fireplace Opening D Sidewall on one side Min 36 914mm Side of Fireplace Opening E Mantel Depth Max Front of Fireplace Opening F Alcove Depth Min 36 914mm Front of Fireplace Opening G Convection Air Outlet Top o...

Страница 26: ...PV installation Clearances CC40LE CC40RE CC40LE shown CC40LE shown E G G G H B I Lo w framing with vents E G B H I Floor to ceiling with top op Floor to ceiling with top opening Low framing with vents in front sides or top ...

Страница 27: ...ies CC40EPV 27 installation Clearances CC40LE CC40RE CC40LE shown CC40LE shown Chase enclosed H E B I H G G H E B I H G G Full framing with vents in front or sides Full framing with low vents in front or sides ...

Страница 28: ...nces CC40LE CC40RE Combustible mantel clearances from top of front facing are shown in the diagram on the right 2 12 6 4 8 10 0 14 9 15 1 16 10 20 26 Top of Fireplace Opening 12 305mm 1 2 Drywall wood wood panel etc 5 1 8 To Bottomof Fireplace Opening ...

Страница 29: ...inthismanualasthere are different methodsastohowthis can be achieved Note This appliance must be in stalled on a level and solid surface such as a plywood floor which must be the full width and depth of the appliance Framing Dimensions Description CC40LE A Framing Height 37 3 8 949mm B Framing Width 48 1 4 1226mm C Framing Depth 19 483mm D Unit Base to Top Enclosure Min 63 1600mm G Vent Centerline...

Страница 30: ... A combined minimum of 120 square inches of open area is required for the convection air outlet to cool the enclosure En sure clearances for Convection Air Outlets are met See clearances CC40RE in this manual astherearedifferentmeth ods as to how this can be achieved Note This appliance must be in stalled on a level and solid surface such as a plywood floor which must be the full width and depth o...

Страница 31: ...ts Note It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel The appliance is designed to be used with 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual Facing Material Facing and or finishing materials must never...

Страница 32: ...aterial being used does not encroach anywhere in the area of the glass This would cause dangerous operating conditions 6 This appliance comes with a 1 2 lip at top sides and bottom to hide the ends of the drywall The 1 2 side and bottom front and bottom side lips supplied with the appliance can alternatively be removed and replaced with J Style Trim or Metal Corner Bead purchased at your local har...

Страница 33: ...orsquaredepending on which unit you have using the diagrams below Attach to the back of the unit using 2 screws in locations shown below 1 This framing kit requires the installation of two studs at locations shown below Be sure to install studs and walls to enclose chase see Unit Manual prior to moving the unit into position Remove nailing flanges Shown for CC40RE Measured from wall to stud center...

Страница 34: ...holes to be used attach to the unit with 2 screws each Part D Profile 3 Install B to the side of the unit use the holes corresponding with the appropriate shape diamond or square depending on which unit you have using the diagrams below Attach B to the side of the unit and install 2 screws in locations shown below E Part E Profile 6 Install venting before proceeding further with framing kit constr...

Страница 35: ... attach to back corner C and front corner F with 2 screws on each side 11 Identify H and attach to both front corners C and F with 2 screws on each side 12 Identify J diagonal support and attach to back corners C and front corner F with 2 screws on each side 13 Attach K center support to E and H with 2 screws each F J K H G 3 CITY SERIES ...

Страница 36: ...ng Studs can be affixed to all outer faces using the holes identified below This will provide a stable surface that is flush with the front of the fireplace ready for drywall or other finishing material The framing must be strong enough to support the weight of all finishing material and must not put any weight on the fireplace BUILDING FRAMING OFF OF THE KIT 1 2 for drywall Leave gap between fram...

Страница 37: ...trate unit more than 1 2 Adhere to No Screw zones painted on unit Glue can be used as an alternative Max 3 To Top of Enclosure 2 120in min Chase vent opening Max 2 x 4 stud Max 2 x 4 stud CB40Typical Installs MAXIMUM TV RECESS FLUSH TV WITH HEARTH 5 8 4 maximum TV recess using 1 2 drywall Flush wall TV recess using 1 2 drywall Max 36 Hearth 1 8 Max 5 Mantle 5 8 Max 4 TV recess with drywall up agai...

Страница 38: ...ng harness through the opening at back of junction box The wiring harness is located near the gas valve and will need to be routed to the exterior of the fireplace from either the left or right hand side prior to finishing 3 Connect the 6 pin connector to the back of the Battery Holder 4 Install the Battery Holder in the Low Voltage Junction box 5 Place the slider into the cover plate 6 Put the Ba...

Страница 39: ...ion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public property 84 2 1m N Clearance under veranda porch deck or balcony 12 30cm 1 In accordance with current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance w...

Страница 40: ... Note Rigid pipe is approved for up to 72 feet Note Flex pipe is approved for up to 40 feet using 2 X 946 756 20 foot flex kits 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 8 Horizontal Feet 4 0 6 10 12 16 18 14 20 22 24 3 Ft max 32 34 28 26 30 36 38 42 44 40 46 48 50 54 56 52 58 60 Vertical Feet 62 64 66 68 70 72 2 4 6 8 Restrictor Factory Set 1 2 72 overall length Max shown with 5 9...

Страница 41: ...anized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanized 46DVA 16A N ...

Страница 42: ...emperatures and may present a possible fire hazard Offset Pipe Selection Use this table to determine offset pipe lengths Pipe Length L 4 x 6 5 8 Venting For specific instructions on venting components visit the manufacturers website listed below Run X Rise Y 0 0mm 4 7 8 124mm 13 7 8 340mm Simpson Direct Vent Pro www duravent com 6 152mm 8 203mm 16 1 2 419mm Selkirk Direct Temp www selkirkcorp com ...

Страница 43: ...hickness ismeasuredfromtheback standoffsto theinsidemounting surfaceofterminationcap Createalevelsurfacetomounttheventterminal TheTerminalmustnotberecessedintosiding Measurethewallthickness Flat Wall Installation Wall Thickness inches Vent Length Required inches 4 5 1 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe Adj Pipe Length Rigid Pipe Adapter o 90 Elbow Pipe ...

Страница 44: ...35 Power Vent Kit with Vent Terminal 1 510 994 Rigid Pipe adaptor sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable sold separately amount required for install 4 x 6 5 8 Rigid Pipe sold separately 1 946 535 Power Vent Kit sold separately Models Equipped with Surefi...

Страница 45: ...ns 120 Volt power supply is required to operate this system 946 535 Power Vent Kit with Vent Terminal 2 Max 946 756 20 Flex Kit sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable sold separately 1 946 535 Power Vent Kit sold separately Models Equipped with Surefire ...

Страница 46: ...est results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Horizontalrunsofventmustbesupportedevery 3 feet 0 9meter Wall straps are available for this purpose 6 Mark the wall for a square hole see chart to lef...

Страница 47: ...which is included with this kit is only required when joining two of the 946 756 flue extension kits to a maximum of 40 feet If only 1 946 756 20 foot kit is used the flex adaptor is not required 1 919 698 06 12 18 60 1 4 Ceiling firestop 60 1 4 Ceiling firestop Diagram 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop En...

Страница 48: ...NOTE Exterior finishes such as thin vinyl siding may warp if closer than 2 from them vent For interior installations on vinyl siding a 2 frame buffer zone must be created between the finishing and the vent 8 Install Power Vent unit into framed opening using 4 screws as shown below 9 Seal the edges of the Power Vent unit to the framing there are two seams 2 Run the venting and BX cable from the uni...

Страница 49: ...e Red Wire Ground Blue Wire Grommet in bracket Grommet in bracket Red to Red Black to Black Black to White 17 Connect remaining wires from powervent motor to BX cable Black to Black and Black to White Cap paired wires with supplied marrette NOTE After exposure to heat White wire will appearYellow Blue wires will appear Green 18 Reinstall rain guard and tighten screws 19 Reinstall front faceplate w...

Страница 50: ...ions 6 8in Access panel removal VFUHZV FFHVV SDQHO VFUHZV 2 Install strain relief and nut as shown below Ensure that the nut is placed on the inner portion of firebox with strain relief on the outer for ease of securing BX cable Strain Relief Nut Strain Relief 3 Bring the BX cable through the strain relief as shown below An overall length of approx 22 559mm should be brought through 4 BX cable bar...

Страница 51: ...moveIFCcoverbyloosening2screws Moveslightlytotheleftandout Ground Lug IFC Board 8 Attach ground wire from BX cable to existing ground lug located on the left hand side of the IFC Control board using supplied locker washer and nut Ground from BX 9 Tuckthe4completedwiresneatlynexttotheIFCboardasshownbelow 10 Secure BX cable to unit floor with supplied clamp as shown below 11 Secure BX cable to clamp...

Страница 52: ...9 920 10 11 18 7 CV40EPV CB40EPV CC40EPV Junction Box 12 Reinstall IFC cover removed in Step 7 13 Once wiring is complete plug unit into power located on the left side of the unit to junction box 14 Reinstall access panel removed in Step 1 ...

Страница 53: ...lation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve should be sup plied in o...

Страница 54: ...electrical power supply is required for the gas control to operate 120 Volt AC power is needed for the lights A receptacle box receptacle and cover are provided and located on the left hand side of the unit under the outer base panel Electrical power must be brought to the appliance by a licensed electrician Do not cut the ground terminal off under any circumstances BLACK BATTERY HOLDER BATTERY CO...

Страница 55: ... clamps in closed position Bottom clamps in closed position Push side glass panel firmly to back wall until springs are compressed then close clamps Important Prior to installing the inner glass ensure that there is no media present in the bottom channel as this can cause damage to the glass Remove any media from bottom channel prior to installing the glass WARNING GLASS HANDLING We recommend usin...

Страница 56: ...red with the front panel in position secure in place by closing the 3 lower clamps and 4 upper clamps Open clamps to release pressure on the springs Press glass vacuum clamps in open position firmly onto surface of glass Bring handles together to close Open Closed 7 Return to the side panel s and release the upper and lower clamps The springs will release and push the glass side panel forward slig...

Страница 57: ...panel shown in image depicting proper handling of glass WARNING GLASS HANDLING We recommend using the glass vacuum holders supplied by the manufac turer Lower the glass to rest in a safe place this is to prevent damage to the glass edges Extra care must be taken when removing installing the glass Breakage or damage to the edge of the glass which occurs as a result of careless handling will not be ...

Страница 58: ...tter illustrate the install this area is not visible when installing glass 4 For 3 sided and corner units only With front panel installed proceed to install the side panel s Identify the left and right side panels before installing Facing the front of the unit the right panel will show an arrow pointing to the front of the unit as shown in the diagram below Note After the side panel has been adjus...

Страница 59: ...agency is re sponsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions sup plied with the kit THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Cable from motor Conversion Kit 657 977 includes 1 911 191 Stepper Moto...

Страница 60: ...ove pilot retainer clip with pliers and pull off the pilot cap to expose the pilot orifice 14 Unscrew the pilot orifice with the allen key then replace with the LPG pilot orifice and the pilot cap provided in the kit Installer Notice These instructions must be left with the appliance Pilot retainer clip 12 Remove burner orifice with a 3 8 wrench Use another wrench to hold on to the elbow behind th...

Страница 61: ... positioned under the outer front base panel to secure the logo The logo should be about 3 inches from the right hand corner of the outer base Install outer front and side base panel 2 Install side panels the side panels are secured in place by existing magnets in the unit The CC40RE CC40LE can be equipped with optional steel inner panels There are 4 outer panels and 3 inner panels NOTE CC40RE sho...

Страница 62: ...l 2 to the back wall of the firebox Center the glass panel and position bottom of panel into brackets installed in step 4 Place the 2 top back brackets on the top edge of the glass and secure to the unit with one screw on each side once back glass panel is in position 4 Slide the supplied bottom corner bracket behind the small panel 1 and the back and side walls in the orientation shown below 3 In...

Страница 63: ...bottom of the panel into the Bottom Corner Bracket and secure the top using the Top Side Bracket as shown Once in position secure the Top Side Bracket to the side wall with one screw Slide the appropriate Top Corner Bracket over the corner between the Side and Back glass panels 9 Install outer side base panel 5 panel 5 rests on the tab of panel 4 10 Install outer side panels 6 7 both panels are he...

Страница 64: ...be unable to remove and will not be protected by product warranty 1 Install inner lower base panel 2 Install panel clips into the slots at the top of the back panel as shown 4 Install panel clip into the slots at the top of the side panel as shown 3 Manoeuvre in back panel to the back wall of the unit secure in place with 2 panel clips and 2 screws 5 Manoeuvre in side panel to the side wall of the...

Страница 65: ...y logo to the right hand side of outer front panel The magnets will be positioned under the outer front base panel to secure the logo The logo should be about 3 inches from the right hand corner of the outer base Install outer front and side base panel 2 Install side panels the side panels are secured in place by existing magnets in the unit 3 Install outer safety glass 4 Reverse steps to remove p...

Страница 66: ...e pilot area Media must be installed on and around burner only in amounts noted below CC40LE CC40RE Approved Media Where Used Quantity Fireglass starfire copper or black On burner 1 5 lbs Glowing embers sea wool supplied with unit On burner 1 bag Natural Stones Around burner 1 box 15lbs Ivory Natural Stones Around burner 1 box 15lbs 3 4 Crushed black glass Around burner 3 5lbs Crushed Iceburg chip...

Страница 67: ...roomtemperature 2 Remove safety glass and firebox glass see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Install Black Fireglass 1 5lb and glowing wool on the burner as shown below Log Guides location of log guides 2 rear 1 front 5 Clip on the log guides position the rear guides by centering over the second ...

Страница 68: ...sure the installed optional media doesn t completely block the air flow ensure more than 50 of the airflow is open shown with 3 4 crushed black glass 11 Place Log 4 identify the pin locator and match with the left side pin on Log 1 Rest the other end of Log 4 on the indent in Log 2 as shown below 12 Place Log 5 identify the pin locator and match with the right side pin on Log 1 Rest the other end ...

Страница 69: ... unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 3 5 2 4 6 7 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Remove safety glass and firebox glass see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Install Black Fireglass 1 5lb and glowing wool on the burner...

Страница 70: ...t the Log 4 on the indent in Log 2 as shown below 12 Place Log 5 identify the pin locator and match with the right side pin on Log 1 Rest the Log 5 on the indent in Log 3 as shown below 10 Before placing the next log spread the optional media evenly throughout the burner tray as shown NOTE Ensure the installed optional media doesn t completely block the air flow ensure more than 50 of the airflow ...

Страница 71: ...all guide and remove guide Note anoffsetscrewdriverisprovidedwiththeapplianceforeaseofremoval installation of the lip and finishing trim p Loosen and tighten screws on drywall guide from inside front panel Loosen 2 screws from inside the firebox to remove the side drywall trim pieces Lower drywall guides 3 Loosen 2 screws from inside the firebox to release the existing side drywall guide remove gu...

Страница 72: ...ng sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit B...

Страница 73: ...pper inside front of the firebox and remove 4 Loosen 2 screws on each side of individual inner light cover and remove 5 Remove glass cover by using a flat head screwdriver to pry the tab securing the glass assembly in place 6 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 Ov...

Страница 74: ...anels firebox glass see instructions in this manual 4 Remove all media and logs if installed set aside 6 Remove 16 screws in locations shown below 7 Lift valve tray by out partially and disconnect flexible gas connection on the valve inlet side remove valve tray replace with new valve tray 8 Reverse steps 6 1 to complete tooltip Remove 16 screws securing valve tray 5 Loosen 4 screws in locations s...

Страница 75: ...11 175 Hand Held Remote Control GTMFL SIT 0 584 042 N S 911 187 Remote Receiver Battery Holder 584 103 N S 910 576 Cover Wall Mount White GTM SIT 0 584 803 N S 911 262 ASM Wire Harness IFC No CPI Switch 584 924 N S 911 177 Wire 4 Position IFC Fan Light N S 911 181 Wire Harness Battery Box Proflame II N S 911 253 ASM Power Cord 120 Volts With Connector N S 911 193 Connector With Jumper N S 911 209 ...

Страница 76: ...arfire 1 4 in 1Lb Pkg N S 946 775 Fireglass Black Reflective 1 4in 5Lb Pkg N S 946 776 Fireglass Copper 1 4 in 5Lb Pkg N S 946 777 Fireglass Starfire 1 4 in 5Lb Pkg N S 946 780 Crushed Glass Coal Black 3 4in 3 5 Lbs N S 946 781 Crushed Glass Iceberg Chips 3 4in 3 5 Lbs N S 946 735 Firebeads Black 1 Lb Pkg N S 946 736 Firebeads Sangria Luster 1 Lb Pkg N S 946 737 Firebeads Glacier Ice 1 Lb Pkg N S ...

Страница 77: ...T 0 584 042 N S 911 187 Remote Receiver Battery Holder 584 103 N S 910 576 Cover Wall Mount White GTM SIT 0 584 803 N S 911 262 ASM Wire Harness IFC No CPI Switch 584 924 N S 911 177 Wire 4 Position IFC Fan Light N S 911 181 Wire Harness Battery Box Proflame II N S 911 253 ASM Power Cord 120 Volts With Connector N S 911 193 Connector With Jumper N S 911 209 Wire 2 Position IFC to Lights N S 910 36...

Страница 78: ...ss Black Reflective 1 4in 5Lb Pkg N S 946 776 Fireglass Copper 1 4 in 5Lb Pkg N S 946 777 Fireglass Starfire 1 4 in 5Lb Pkg N S 946 780 Crushed Glass Coal Black 3 4in 3 5 Lbs N S 946 781 Crushed Glass Iceberg Chips 3 4in 3 5 Lbs N S 946 735 Firebeads Black 1 Lb Pkg N S 946 736 Firebeads Sangria Luster 1 Lb Pkg N S 946 737 Firebeads Glacier Ice 1 Lb Pkg N S 946 738 Firebeads Caramel Luster 1 Lb Pkg...

Страница 79: ... Front Faceplate 6 946 130 Power Vent SS Outer Perimeter Trim 7 946 157 Power Vent SS Water Deflector 8 911 047 Silicone Tubing Sold Per Foot 6 inches required For Power Vent 9 946 163 Pressure Switch Sensor Bracket 10 946 539 Power Vent Outer Intake Assembly N S 946 540 Power Vent Inner Intake Assembly N S 911 254 Pressure Switch Wire Harness Blue Red N S 911 255 Pressure Switch Wire Harness Shri...

Страница 80: ... Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled compon...

Страница 81: ...ation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are n...

Страница 82: ...ld consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief descript...

Страница 83: ...for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CAN...

Страница 84: ...84 City Series CC40EPV ...

Страница 85: ...City Series CC40EPV 85 notes ...

Страница 86: ...86 City Series CC40EPV notes ...

Страница 87: ......

Страница 88: ..._________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ ...