![Regency Fireplace Products Plateau PTO50 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/regency-fireplace-products/plateau-pto50/plateau-pto50_owners-and-installation-manual_1433974026.webp)
26
|
Regency Plateau® PTO50 Outdoor Gas Fireplace
|
26
installation
PTO50 WIRING DIAGRAM
This appliance does not require a 120V A.C. supply for operation.
NOTE: 4 AA batteries must be installed in the battery pack to operate the burner switch. Do not use a 9 volt battery.
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the
National Electrical
Code, ANSI/NFPA 70
,
if applicable.
PTO100 WIRING DIAGRAM
(TWO PTO50S ASSEMBLED END-TO-END)
0.886.001
Proflame Valve
Standard Main On/Off Switch
or Optional Wall Switch
1 of 10
Optional
ON/OFF Switch
Battery Holder
1 of 10
1 of 10
Optional
Optional
Содержание Plateau PTO50