![Regency Fireplace Products Plateau PTO50 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/regency-fireplace-products/plateau-pto50/plateau-pto50_owners-and-installation-manual_1433974014.webp)
14
|
Regency Plateau® PTO50 Outdoor Gas Fireplace
|
14
installation
FINISHING
Side nailing strips are adjustable for material from a minimum of 1/2" thick
up to a maximum of 2-3/8" thick.
The finishing materials cannot extend beyond the height of the burner.
Optional finishing trim is not supplied with the PTO50 - if purchased, place finishing trim on unit between unit and finishing material.
Note: Optional trim is not available for the PTO80 and PTO100.
Side nailing strips are adjustable in 1/4" or 1/8" increments. Each hole on
the inside line is 1/8", each hole on the outside line is 1/4"
Determine the thickness of the finishing material before adjusting the nailing
strips.
OPTIONAL FINISHING TRIM
1/2"
1/4" Increments
1/8" Increments
2-3/8"
Nailing strip
FINISHING MATERIALS:
This burner is designed to be finished with non-combustible materials (ie.
tile, granite, marble, brick, etc.) with a minimum thickness of 1/2" to a maxi-
mum thickness of 2-3/8".
Burner Opening Size
PTO50 56-7/8" x 8-5/8"
PTO80 90-1/8" x 8-5/8"
PTO100 106-7/8" x 8-5/8"
Min. 1/2"
Max. 2-3/8"
Important Note:
Two (2) ventilation grills, (PTO50), Four (4) ventilation
grills (PTO80 & PTO100) are highly recommended for all enclosures.
This is to alleviate moisture and allow for air to circulate.
Minimum recommended size : 20" sq (508 mm ²) each.
The ventilation grills must be located at the ends of the burner.
Содержание Plateau PTO50
Страница 48: ...48 Regency Plateau PTO50 Outdoor Gas Fireplace 48 notes...
Страница 53: ...Regency Plateau PTO50 Outdoor Gas Fireplace 53 53 warranty...
Страница 54: ...54 Regency Plateau PTO50 Outdoor Gas Fireplace 54 notes...
Страница 55: ......