background image

2    | 

Regency I2404

2    |

Thank-you for purchasing a 

REGENCY FIREPLACE PRODUCT.

The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product 

that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.

“This wood heater has a manufacturer set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise 

operate this wood heater in a manner inconsistent with operating instructions in this manual." Failure to follow the manual details can lead to smoke and CO 

emissions spilling into the home. It is recommended to have monitors in areas that are expected to generate CO such as heater fuelling areas.

“U.S. ENVIRONMENTAL PROTECTION AGENCY

 Certified to comply with 2015 particulate emission standards using crib wood". Not approved for sale after 

May 15, 2020.”

Model Regency I2404

SAFETY NOTE

: If this woodstove is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building, 

fire officials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.

The following statements are required by the Environmental Protection Agency:

“This manual describes the installation and operation of the Regency I2404 wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s 

crib wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 12,000 BTU/hr. to 

36,800 BTU/hr.” ”This unit has been tested using 5G series and generates the best efficiency when operated using well-seasoned wood and installed in the 

main living areas where the majority of the chimney is within the building envelope and fully lined.”

"It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if any parts are removed. “

It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual.

CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL,

PLASTIC, GARBAGE, SULPHUR OR OIL MAY DAMAGE THE HEATER

"This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as 

compared to softwoods or to green or freshly cut hardwoods."

DO NOT BURN: 

 

•  Treated wood

•  Lawn clippings or yard waste

•  Manure or animal remains

•  Coal

•  Materials containing rubber including tires

•  Saltwater driftwood or other previously salt water 

saturated materials

•  Garbage

•  Materials containing plastic

•  Unseasoned wood

•  Cardboard

•  Waste petroleum products , paints or paint thinners or asphalt products

•  Paper products, cardboard, plywood or particle 

board. The prohibition against burning these 
materials does not prohibit the use of fire starters 
made from paper, cardboard, saw dust, wax and 
similar substances for the purpose of starting a 
fire in a wood heater

•  Solvents

•  Materials containing asbestos

•  Colored Paper

•  Construction or demolition debris

•  Trash

•  Railroad ties

Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke. 

The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bureau, etc.) should be consulted before installa

-

tion to determine the need to obtain a permit.

This unit must be connected to either a listed factory built chimney suitable for use with solid fuels and conforming to ULC629 in Canada or UL-103HT in the 

United States of America or code approved masonry chimney with flue liner.

I2404 is tested and certified to ULC-S628 and UL1482.

SAVE THESE INSTRUCTIONS

Содержание I2404M

Страница 1: ...a V4G 1H4 919 032c MODELS I2404M WOOD Fireplace Insert 01 30 18 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Pl...

Страница 2: ...of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if an...

Страница 3: ...allation 10 Installation of the Faceplate and Trim 11 Installation of the Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door H...

Страница 4: ...THE MANUFACTURER SUPPLIED SCREEN MUST BE USED REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP IDLY DO NOT...

Страница 5: ...Regency I2404 5 5 dimensions 5 5 9 UNIT DIMENSIONS I2404M...

Страница 6: ...Install and use only in accordance with manufac turer sinstallationandoperatinginstructions 2 Check your local building codes Building Inspection Department You may require a permit before installing...

Страница 7: ...nto position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet...

Страница 8: ...RANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE...

Страница 9: ...flue or liner is in use the insert is able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glas...

Страница 10: ...h bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper in...

Страница 11: ...on and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed wit...

Страница 12: ...temperature or at least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided...

Страница 13: ...he air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring...

Страница 14: ...ondition 3 Do not burn large quantities of paper in your insert 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Donotoverfireyourinsert Iftheinsertbegin to glow you...

Страница 15: ...luelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fa...

Страница 16: ...all deposits GLASS REPLACEMENT Your Regency Insert is supplied with 5 mm Neoceram ceramic glass Part 846 304 that will withstand the highest heat that your unit will produce In the event that you brea...

Страница 17: ...3 Regency Logo Nickel 948 216 Regency Logo Gold 48 820 482 Stainless smoke deflector 918 993 Manual Not available as a replacement part Part Description 1 850 152 Door Assy Large Gold 850 151 Door Ass...

Страница 18: ...lar 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 29...

Страница 19: ...2404 19 19 parts list BRICK PANELS I2404M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4...

Страница 20: ...rorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defec...

Страница 21: ...ype operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents car...

Страница 22: ...additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized...

Страница 23: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Produ...

Страница 24: ......

Страница 25: ...25...

Страница 26: ...26 Regency I2404 26 notes...

Страница 27: ...Regency I2404 27 27 notes...

Страница 28: ...______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _____________...

Отзывы: