background image

 

Regency I2404    

|

   

 13

13

installation

 Pull Open                Push Closed

ensure the tube will not move when the unit 

is burning. Though there are  four air tubes 

in the medium units.

2)

  Slide the left baffle over the air tubes from 

the front and then push it to the  back. 

4)  Important: push both baffles so they are 

tight against the side walls. 

Side View

Front View

Front View

3) 

Tilt the left baffle up on top of the side chan

-

nel and it will leave enough room to position 

the right baffle in the same manner as Step 

1) above. Then reposition the left baffle flat 

on the air tubes.  

DRAFT CONTROL

Before establishing your first fire, it is important 

that your fully understand the operation of you 

draft control. The draft rod is on the left side of 

the Inserts and it controls the intensity of the 

fire by increasing or decreasing the amount of 

air allowed into the firebox. To increase your 

draft - pull open, and to decrease - push closed.

As well as a primary and glass wash air system, 

the unit has a full secondary draft system that 

allows air to the induction ports at the top of the 

firebox, just below the flue baffle.

WARNING:  To build a fire in ignorance or 

to  disregard  the  informa tion  contained  in 

this section can cause serious permanent 

damage to the unit and void your warranty.

The unit arrives with the  2 baffle plates on the 

floor of the firebox. 

1)

  If all 4 air tubes are installed continue on 

to  Step  2),  if  not,  follow  the  instructions 

below. Install the air tube into the holes in 

the side channels. The notch goes on the 

right hand side with the air holes facing 

toward the door. Slide the tube into the left 

hand side, as far as possible and then bring 

it back into the hole on the right hand side.  

Use a pair of vise grips or pliers and tap it 

into place with a hammer.  A tighter fit will 

FLUE BAFFLE & 
SECONDARY AIR TUBE 
INSTALLATION

The flue baffle system located in the upper area 

of the firebox is removable to make cleaning your 

chimney system easier.  The  baffles must be 

installed prior to your first  fire. 

 Smoke spill

-

age and draft problems may occur if  the 

baffles  are  improperly  positioned. 

 Check 

the position of the baffles on a regular basis as 

they can be dislodged if too much fuel is forced 

into the firebox. 

FLOOR PROTECTION

Please check to ensure that your floor protection 

and hearth will meet the standards for clearance 

to combustibles. Your hearth extension must be 

made from a non-combustible material.

FIREBRICK ASSEMBLY

Firebrick is included to extend the life of your 

insert and radiate heat more evenly.  Check to 

see that all firebricks are in their correct posi

-

tions and have not become misaligned during  

shipping.

SCREEN DOOR

Hook screen to the inside on the right side 

of the firebox door opening. Lock in place by 

turning handle.

Back Side of Screen Shown

DOOR HANDLE

Attach spring handle by rotating counter clock-

wise onto rod.  Ensure that the rod fits into the 

entire length of the spring handle. 

NOTE:

 The handle must be positioned at 10 

o'clock when closed to avoid the handle from 

getting hot and to ensure the screen stays in 

place.

Handle Lock

Hooks

Handle at 10 o'clock position.

Содержание I2404M

Страница 1: ...a V4G 1H4 919 032c MODELS I2404M WOOD Fireplace Insert 01 30 18 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Pl...

Страница 2: ...of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if an...

Страница 3: ...allation 10 Installation of the Faceplate and Trim 11 Installation of the Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door H...

Страница 4: ...THE MANUFACTURER SUPPLIED SCREEN MUST BE USED REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP IDLY DO NOT...

Страница 5: ...Regency I2404 5 5 dimensions 5 5 9 UNIT DIMENSIONS I2404M...

Страница 6: ...Install and use only in accordance with manufac turer sinstallationandoperatinginstructions 2 Check your local building codes Building Inspection Department You may require a permit before installing...

Страница 7: ...nto position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet...

Страница 8: ...RANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE...

Страница 9: ...flue or liner is in use the insert is able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glas...

Страница 10: ...h bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper in...

Страница 11: ...on and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed wit...

Страница 12: ...temperature or at least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided...

Страница 13: ...he air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring...

Страница 14: ...ondition 3 Do not burn large quantities of paper in your insert 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Donotoverfireyourinsert Iftheinsertbegin to glow you...

Страница 15: ...luelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fa...

Страница 16: ...all deposits GLASS REPLACEMENT Your Regency Insert is supplied with 5 mm Neoceram ceramic glass Part 846 304 that will withstand the highest heat that your unit will produce In the event that you brea...

Страница 17: ...3 Regency Logo Nickel 948 216 Regency Logo Gold 48 820 482 Stainless smoke deflector 918 993 Manual Not available as a replacement part Part Description 1 850 152 Door Assy Large Gold 850 151 Door Ass...

Страница 18: ...lar 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 29...

Страница 19: ...2404 19 19 parts list BRICK PANELS I2404M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4...

Страница 20: ...rorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defec...

Страница 21: ...ype operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents car...

Страница 22: ...additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized...

Страница 23: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Produ...

Страница 24: ......

Страница 25: ...25...

Страница 26: ...26 Regency I2404 26 notes...

Страница 27: ...Regency I2404 27 27 notes...

Страница 28: ...______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _____________...

Отзывы: