Regency Horizon
®
HZ33CE-11 Gas Fireplace
| 41
installation
Proflame System
Configuration
886 GTMF
Wire Diagram
SureFire™ Switch
885
1 of 10
AC Adaptor
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
WIRING DIAGRAM
This heater does not require a 120V A.C. supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries.
In case of a power failure, the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver.. However, a 120V
A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the
fan is installed at a later date.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
AERATION ADJUSTMENT
The burner aeration is factory set but may need ad-
justing due to either the local gas supply or altitude.
Open the air shutter for a blue flame by pulling down
on the rod or close for a more yellow flame by pushing
up on the rod.
Minimum Air Shutter Opening:
NG
1/16"
NG with Logs
3/16”
NG with Stones
3/16”
LP
3/16"
LP with Logs
Full open
LP with Stones
Full open
CAUTION:
Carbon will be produced if air shutter is tightly
closed.
Note: Any damage due to carboning resulting
from improperly setting the aeration controls
is NOT covered under warranty.
0.584.622