Regency Horizon
®
HZ33CE-11 Gas Fireplace
| 39
installation
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa). Disconnect piping from valve at pressures
over 1/2 psig.
The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1. Make sure the valve is in the "OFF" position.
2. Loosen the "IN" and/or "OUT" pressure tap(s),
turning counterclockwise with a 1/8" wide flat
screwdriver.
3. Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4. Light the pilot and turn the valve to "ON"
position.
5. The pressure check should be carried out
with the unit burning and the setting should
be within the limits specified on the safety
label.
6. When finished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" flat
screwdriver.
Note: Screw should be snug,
but do not over tighten.
HIGH ELEVATION
This unit is approved in Canada for altitude to 4500 ft.
(CAN/CGA-2.17-M91). For Natural Gas installations
above 4500 ft. follow current CAN/CGA-B149.1.
PILOT ADJUSTMENT
Periodically check the pilot flames. Correct flame
Note: If you have an incorrect flame pattern,
contact your Regency
®
dealer for further
instructions.
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact
with the rear burner or flame sensor.
pattern has two strong blue flames: 1 flowing
around the flame sensor and 1 flowing across
the burner (it does not have to be touching the
burner).
Burner
Flame Sensor
Pilot
Ignitor
885 S.I.T. VALVE DESCRIPTION
1) 6 Stage flame adjustment
2) Pilot adjustment
3) Inlet Pressure Tap
4) Outlet Pressure Tap
5) Pilot Outlet
6) Main Gas Outlet
7) Main Gas Inlet
1
2
3
4
6
5
7
1
2
3
4
6
5
7
HZ33CE-NG11 System Data
Conversion Kit# 433-971
NG to LP
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes: #47
Max. Input Rating
Min. Input Rating
17,000 Btu/h
12,000 Btu/h
Supply Pressure
min. 5.0'' w.c.
Manifold Pressure
(High)
3.5'' w.c.
HZ33CE-LP11 System Data
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes: #56
Max. Input Rating
Min. Input Rating
15,000 Btu/h
12,500 Btu/h
Supply Pressure
min. 11.0'' w.c.
Manifold Pressure
(High)
10'' w.c.