installation
MANTEL CLEARANCES
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the
paint may discolour.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances from side of unit as per diagram:
Top View
0-3
Allowable mantel leg projection
6-3/4"
9"
Side opening of Unit
Due to the extreme heat this fireplace emits, the
mantel clearances are critical. Combustible mantel
clearances from top of front facing are shown in the
diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing is
made of metal studs covered with a non-
combustible board. The non-combustible
mantle when installed at a lower overall
height may not be lower than 6 inches
from the top of the fireplace opening.
Drywall
Mantel Clearances
2
0
12
6
4
8
10
2
0
12
6
4
8
10
Top opening
of Unit
12" (305mm)
0” - 3-1/2" (89mm)
7-1/2"(191mm)
15-3/4" (400mm)
11-3/4"(298mm)
13-3/4"(349mm)
24-1/4"(616mm)
to floor
3"(76mm)
Standoff
Side View
16
14
Non-combustible material