background image

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

920-041f

03.04.21

Owners & 

Installation Manual

www.regency-fire.com

MODEL: H

Z

33CE-NG11 Natural Gas

                H

Z

33CE-LP11  Propane

HZ33CE Video

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appli-

ance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

Regency Horizon

®

 HZ33CE 

Gas Fireplace

Installer: 

 

Please complete the details on the back cover and leave 
this manual with the homeowner.

Homeowner

:

 

Please keep these instructions for future reference.

Certified to/Certifié pour:   CSA 2.17-2017
                                            ANSI Z21.88-2017
                                          CSA 2.33-2017

Tested by: 

Содержание HORIZON HZ33CE

Страница 1: ...mediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property d...

Страница 2: ...all the warmth and charm of a fire at the flick of a switch The model HZ33CE has been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Страница 3: ...y or mobile home where not prohibited by local codes This appliance can only be used with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Kit 434 972 Ensure that structural members are not cut or weakened during installation Horizon Benefits Video HZ33CE Video ON DEMAND PILOT LIGHT SEVEN DAY SAFETY TIMER Import...

Страница 4: ... Horizontal Termination 35 Unit Installation with Vertical Termination 36 Gas Line Installation 36 OWNER S INFORMATION INSTALLER S INFORMATION Vertical Termination 4 x 6 7 8 Venting Vertical Flex Vent Kit 37 Vertical Flue Extension Kit Part 946 756 38 Ceiling Firestop Firestop Spacer Part 946 757 38 Pilot Adjustment 39 High Elevation 39 System Data 39 Gas Pipe Pressure Testing 39 885 S I T Valve D...

Страница 5: ...12 000 Btu h 3 51 kW 17 000 Btu h 4 98 kW 0 4500 ft pi 0 1372 m This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas and Propane Installation Code CSA B149 1 This appliance must be installed in accordance with the Standard CAN CSAZ240 MH Mobile Housing in Canada or with the Manufactured Home Construction and Saf...

Страница 6: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspect...

Страница 7: ...mm 29 1 4 76mm 3 36 3 4 42 5 16 6 3 8 2 51mm 162mm 1074mm 933mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS Note Gas connection is from the right hand side of the appliance electrical connection on left hand side of the appli ance A metal receptacle box is supplied installed with the appliance to make all...

Страница 8: ...utside of the building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per Venting instructions 5 Inspecttheventingsystemannuallyforblockage and any signs of deterioration 6 Venting terminals shall not be recessed into a wall or siding 7 Any safety glass removed for servicing must be replaced prior to operating the appliance 8 To prevent injury do not ...

Страница 9: ...ximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF but...

Страница 10: ...staller service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de ...

Страница 11: ...y TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote control malfunction turn off th...

Страница 12: ...y one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The th...

Страница 13: ...culating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary f...

Страница 14: ...urner operating cycle is completed The mode of the fireplace is easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using the silver toggle switch located on the fireplace See noted location of CPI IPI Switch The benefits of having CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions K...

Страница 15: ...cation Refer to LocatingYour Gas fireplace section b Clearances to Combustibles Refer to Clearances section c Mantle Clearances Refer to Mantel Clearances section d Framing Finishing Requirements Refer to Framing Finishing section e Venting Requirements Refer to Venting section 2 AssembleTopandSideStandoffs Referto Unit Assembly Prior to Installation 3 Slide unit into place 4 Install vent Refer to...

Страница 16: ...e of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions C F G Clearance Dimension Measured From A Front Floor Clearance min 0 Underside of Unit B Sidewall on one side 9 229mm Side Opening of Unit C Ceiling room and or alcove 3...

Страница 17: ... are critical Combustible mantel clearances from top of front facing are shown in the diagram on the right Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board The non combustible mantle when installed at a lower overall height may not be lower than 6 inches from the top of the fireplace opening Drywall Mantel C...

Страница 18: ...materials such as tile slate etc Drywall cannot extend beyond the metal surface of the unit 8 Tile Finish Option 2 If applying a non combustible finishing material tile slate etc the material can be installed directly onto the metal surface clean front of the unit in the area shown below 29 7 16 747mm 21 3 8 542mm Nailing strip for Tile Finish set back 1 2 Nailing strip for Clean Finish set flush ...

Страница 19: ...uctions in the manual exactly you will increase your chances of a damage free finish While every precaution is taken in providing the recommendations on preparation and finish given the variations in paint quality with temperature limits and workmanship in application Regency is unable to guarantee the life of the joint compounds paint or any other finish materials or workmanship applied to or use...

Страница 20: ...ustible facingmaterialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or metal cornerbead both materials available at your local building or hardware store IMPORTANT Materials used must be NON COMBUSTIBLE CLEAN FINISH 6 If applying a non combustible fac...

Страница 21: ...Rigid 16 406mm Flex K Corner Wall Length 38 15 16 988mm L Corner Facing Wall Width 55 1 2 1410mm M Framed Chase Ceiling 36 914mm Rigid 32 812mm Flex N Vent Centerline Height 30 762mm Rigid 26 660mm Flex O Gas Connection Height 1 1 2 38mm P Gas Connection Inset 7 3 16 183mm Q Gas Connection Width 3 76mm FRAMING DIMENSIONS NOTE If this is an outside corner the minimum distance between the vent and t...

Страница 22: ... for use with the HZ33CE see following Venting Sections for more details on approved vent systems Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Each direct vent gas appliance must use it s own separat...

Страница 23: ...ended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public...

Страница 24: ...the parts needed to install the HZ33CE with a maximum run of 2 feet If in stalling the HZ33CE 11 with a continuous vent length of more than 2 ft 6m to a maximum of 10 ft 3 0m use Kit 946 515 4 ft or 946 516 10 ft or see Rigid Pipe Venting Systems Section for alternate venting arrangements Minimum Flex Kit Center Line Minimum Rigid Pipe Center Line AstroCap Flex Kits 1 6 7 8 dia flexible liner kit ...

Страница 25: ...n conjunction withDuraventDirect Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components WARNING Do not combine venting components from different venting systems Exception However use of the the AstroCapTM and FPI Riser is acceptable with all sy...

Страница 26: ...djustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A N A Extension Pipe 16 Black 46DVA 16AB N A N A N A N A N A N A 45º Elbow Galvanized 46DVA E45 4DT EL45 4D45L N A N A TE 4DE45 VDV EL0445 45º Elbow Black 46DVA E45B 4DT EL45B 4DT EL45B N A N A TE 4DE45B V...

Страница 27: ...AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523 P AstroCap Horizontal Cap 946 206 Vinyl Siding Standoff for AstroCap The rigid pipe adaptor is not required on the C34 C34E U39 U39E H15 H27 H35 RC500E Note When using Metal Fab Sure Seal R...

Страница 28: ... combinations of straight vertical and offset to vertical terminations using one 90o elbow with rigid pipe vent systems for Propane and Natural Gas Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles Vent must be supported at offsets Note Must use optional rigid pipe adapter when using rigid vent systems Part 510 994 ...

Страница 29: ...ns Section for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor 46DVA E45 45o Elbow Alternate Approved Caps 46DVA VC Vertical Termination Cap 46DVA VCH High Wind Cap 46DVA...

Страница 30: ...es into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet Floor 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet 2 51mm max Floor 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet ...

Страница 31: ...ns using one 45o and one 90o elbow two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Refer Rigid Pipe Venting Systems Section Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever ...

Страница 32: ... H1 H2 With these options maximum total pipe length is 30 feet with minimum of 11 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between90o elbows is required A 1 Max 1 Min 3 Max B 2 Max 3 Min 5 Max C 3 Max 5 Min 6 Max D 4 Max 7 Min 7 Max E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max Horizontal Venting with Two 2 90o Elbows One 90o elbow Two 45o elbows Option...

Страница 33: ...n 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Min 8 Max F 7 Min 6 Max 12 Min 9 Max One 90o elbow Two 45o elbows Option V H V V1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 1 Min 4 Max 2 Min B 2 Min 5 Max 3 Min C...

Страница 34: ...elbows One 90o elbow Two 45o elbows With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows is required Option V H H1 V V1 A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min Withtheseoptions max total pipelengthis30feetwithmi...

Страница 35: ... are designed with special twist lock connections to connect the venting system to the appliance flue outlet A twist lock appliance adaptor is an available option that must be used in conjunction with the Simpson Dura Vent Direct Vent system 3 Put a bead of Mill Pac inside the outer section of the adapter and on the inner collar Slip the adapter over the existing inner and outer flue collar and fa...

Страница 36: ...approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result indraftingorperformanceissuesnotcovered under warranty 8 Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly It is important that the vent pipe extends into the vent cap sufficient distance so ...

Страница 37: ...EX VENT KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it reaches the flashing...

Страница 38: ...gram 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling le...

Страница 39: ...w clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten HIGH ELEVATION ThisunitisapprovedinCanadaforaltitudeto4500ft CAN CGA 2 17 M91 ForNaturalGasinstallations above 4500 ft follow current CAN CGA B149 1 PILOT ADJUSTMENT Periodicallycheckthepilotflames Correctflame Note If you have an incorrect flame pattern contactyourRegency dealerforfurther instructions Incorr...

Страница 40: ...esh barrier and glass door b Remove the Glass Crystals or Ceramic Stones Also remove Inner Panels if installed c Remove the six 6 screws in locations shown below to remove burner tray 6 Unscrew the pilot orifice with the Allen key and replace with the LPG pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the elbow ...

Страница 41: ...mstances NOTE Even if the fan is not purchased with the unit it is still a good idea to bring power to the receptacle box provided with the unit in case the fan is installed at a later date CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation AERATION ADJUSTMENT The burner aeration is factory set but may need ad justing due to either...

Страница 42: ... insulation on the fan base Ensure the fan blades do not rub against the valve tubing 4 Connect the power cord and fan ground wires to the ground lug Refer to wiring diagram 5 Slide the thermodisc cover assembly on to the bracket clip on the underside of the firebox Thermodisc Clip 6 Install the Fan Control Module FCM on the base of the unit to the left of the gas valve Plug the FCM into the outle...

Страница 43: ... Remove 2 screws in the locations shown below Slide burner to the right then lift out See Diagram 2 5 Remove the 12 screws securing the valve tray assembly in place Then lift the assembly out See Diagram 3 6 Manoeuvre the fan into the valve tray opening at the base of the firebox 7 Secure the fan by pushing it down onto the mounting pins locat ed on the floor of the unit Take care not to damage th...

Страница 44: ...e off position 12 See the Proflame instructions for coding the remote handheld to the receiver and for operating instructions 13 Reverse Steps 6 1 to complete the installation TO REMOVE THE FAN 1 Shut the power off 2 Reverse the above instructions Note The bearings are lubricated for life Do not lubricate them Make sure you vacuum the fan area on a regular basis IMPORTANT These fans collect a lot ...

Страница 45: ...0 584 622 This heater does not require 120 volt AC supply for operation of the burner but is highly recommended as a primary power source to eliminate the need for 4 AA batteries Batteries should only be used as a secondary power source when power is lost within the home 120 Volt AC power is also required for the optional blower NOTE Even if the fan is not purchased with the unit it is still a goo...

Страница 46: ...es will be located near the gas valve Disconnect greenTH wire Green Wires White Connector 3 Connect one thermostat lead to female connector using male spade con nector see picture below CAUTION Do not wire Thermostat wires to 120V wire 4 Connect the other thermostat lead to male connector disconnected from Step1 using a female spade connector see picture below When complete turn remote receiver to...

Страница 47: ...installation panels must be handled and cleaned as per instructions noted below Black Enamel Panels Black Enamel panels must be inspected for scratches and dimples prior to installation All claims to be recorded at this time Claims for damage after installation will not receive consideration Black Enamel panels will discolor a little during normal operation This is normal and should not be conside...

Страница 48: ...it s performance any damage caused by the use of any unapproved glass or stones will not be covered under warranty When using ceramic spa volcanic stones ensure required glass crystals beads are used as a base DO NOT overstack Ceramic spa stones or Volcanic stones on the burner or in the pilot area 1 Start installing Crystals on back of Burner and Firebox Floor 2 Distribute Crystals evenly towards...

Страница 49: ...e fragile handle with care never force into position 4 Ensure glass crystals are installed on the burner HZ33CE 4lbs HZ30E 1lb HZ33CE INSTALL INSTRUCTIONS 5 HZ33CE only Install log bracket onto left side of burner with 1 screw as shown below Note The screw in this location will need to be removed to secure the bracket HZ33CE install bracket left side 6 Install log clip to lip on burner tray positi...

Страница 50: ...own Left Log 2 positioned to rest on Log 1 and glass crystals HZ33CE shown Final Install 2 1 HZ33CE use bottom pin landing 1 2 3 HZ33CE use bottom pin landing 1 4 5 2 4 12 Place lava embers rocks on glass ensure rocks do not block pilot Do not place lava rocks embers too close to logs as this may cause carboning 13 Adjust aeration see unit manual for setting 11 Position Log 3 line up bottom pin la...

Страница 51: ...y on the unit See Diagram 3 SAFETY SCREEN 1 To remove the safety screen grasp safety screen on both sides from the bot tom Lift up and out slightly to release from bottom magnets and to release hooks on mesh frame from brackets inside unit see below Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket Repeat for 2nd spring See Diagram 4 To remove ...

Страница 52: ...crews two 2 on each side of the bracket into the wall studs as shown below Diagram 1 Materials flush w unit Diagram 2 Bracket screw locations on unit Diagram 3 Bracket screw locations Diagram 4 Line up faceplate and bracket Middle Rib on Faceplate Diagram 6 Final Install Diagram 5 Hang faceplate on bracket 3 Lineupthemiddleribonbacksideoffaceplatewithmiddleindentonbracket This will centre the face...

Страница 53: ...y require cleaning NOTE Whentheglassiscoldandtheappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE FIRST FIRE NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some soun...

Страница 54: ...y 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF button if ...

Страница 55: ...ller service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l i...

Страница 56: ...ly Recommended areas to inspect as follows 1 Check the Venting System for corrosion in areas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These components should be replaced immediately 2 Remove the Cap and shine a flashlight down the Vent Remove any bird nests or other foreign material 3 Check for evidences of excessive condensation suchas...

Страница 57: ...ase tray Installing Valve 1 Install new Valve Tray Assembly 2 Reverse steps 8 1 Diagram 5 Lift out Valve Tray Assembly Diagram 4 Diagram 2 Diagram 3 5 Remove 2 screws in location shown below slide burner to the right then lift out See Diagram 2 8 Remove the 12 screws securing the valve tray assembly in place Diagram 4 and then lift the entire assembly out Diagram 5 NOTE Parts have been hidden to s...

Страница 58: ...list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should a...

Страница 59: ...tepper Motor Modulator NG 9 910 011 Stepper Motor Modulator LP 911 228 P Remote Receiver 11 940 088 P Replacement Glass with Gasket 936 155 Glass Gasket sold per foot 8 Feet required 904 691 Glass U Clip each Part Description 10 438 917 Fan Assembly 910 331 P Fan Motor Only 911 030 Fan Control Module 12 438 529 Mesh Guard 13 433 538 Door Assembly 14 438 512 Clean Front Face Not a replacement part ...

Страница 60: ...irebeads 946 737 Glacier Ice Firebeads 946 738 Caramel Luster Firebeads 5 Pound Bag of Firebeads 946 739 Black Firebeads 946 740 Sangria Luster Firebeads 946 741 Glacier ice firebeads 946 742 Caramel Luster Firebeads Part Description 1 pound bag of glass crystals 946 675 Black Reflective Crystals 946 676 Copper Crystals 946 677 Starfire Crystals 5 pound bag of glass crystals 946 775 Black Reflecti...

Страница 61: ...Regency Horizon HZ33CE 11 Gas Fireplace 61 notes ...

Страница 62: ...rol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assemb...

Страница 63: ...ts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appli...

Страница 64: ...e U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brie...

Страница 65: ...in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases ma...

Страница 66: ...66 Regency Horizon HZ33CE 11 Gas Fireplace warranty ...

Страница 67: ......

Страница 68: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial ___________________________________________...

Отзывы: