background image

 

F2404 Freestanding Wood Fireplace

  |    9

9

installation

RESIDENTIAL  
INSTALLATION

1)

  Please read this entire manual before you 

install and use your new woodstove. Failure 

to follow instructions may result in property 

damage, bodily injury or even death. Be aware 

that local Codes and Regulations may override 

some items in this manual. Check with your 

local inspector.

2) 

Select a position for your Regency Stove. 

Consult the minimum clearance chart for your 

model and set the stove in place. For close 

clearance installation use listed double wall 

connector systems.

3)

  To insure vertical alignment, suspend a plumb 

bob from the ceiling over the exact center of 

your stove flue and mark a spot on the ceiling 

to indicate the center of the chimney.

4) 

Check that the area above the ceiling is clear 

for cutting. Re-confirm the clearance from the 

stove to combustibles to insure that they are 

within the prescribed limits.

5)

  This woodstove must be connected to a UL 

103 HT (ULC S629) listed chimney or a code 

approved masonry chimney with a flue liner.

6) 

Install chimney according to chimney manu-

facturers instructions. The performance of your 

woodstove is governed to a very large part 

by the chimney system. Too short a chimney 

can cause difficult start-up, dirty glass, back 

smoking when door is open, and 

even reduced heat output. Too tall a chimney 

may prompt excessive draft which can result 

in very short burn times and excessive heat 

output. The use of an inexpensive flue pipe 

damper may be helpful in reducing exces-

sive draft.

 CAUTION

: The chimney should be the same 

size as the 6" flue outlet on the stove. The 

chimney must be listed as suitable for use 

with solid fuels. For other types of chimneys 

check with your local building code officials. 

Do not confuse a chimney with a type “B” 

Venting System used for gas appliances 

as suitable for a wood burning appliance. 

For Mobile Home installations refer to that 

section within this manual.

7) 

Mark the location of the pedestal base or 

legs on the floor, then move the stove aside 

and mark the position of the floor protector.

8) 

The floor protector must be of non-combus

-

tible material and must extend 16" (406mm)  

in front of the door opening and 6" (152mm) 

to the sides and rear of the unit.  Some areas 

may  require  a  larger  size  floor  protector.  

See your local inspector.  For outside air 

installation refer to Mobile Home installation 

instructions within this manual.

9)

  When the floor protection is complete, posi

-

tion the stove with the flue collar centered 

under the installed chimney.

10)

 In seismically active areas, Regency rec-

ommends that your unit is secured to the 

floor by using the bolt down holes inside 

the pedestal (the same ones used in Mobile 

Home installations).

11)

 For  residential  installations  using  6"  "C" 

Vent  (single  wall)  the  chimney  connector 

must be at least 24 gauge steel. Do not use 

galvanized pipe. For Mobile Home instal-

lation refer to the Mobile Home installation 

instructions within this manual.

12)

 

Do not connect this unit to a chimney 

serving another appliance.

13)

 A chimney connector cannot pass through 

an attic or roof space, closet or similar 

concealed  space,  or  a  floor,  ceiling,  wall 

or partition of combustible construction. 

In Canada, if passage through a wall, or 

partition of combustible construction is 

desired, the installation shall conform to 

CAN/CSA-B365, Installation Code for Solid-

Fuel-Burning Appliances and Equipment.

14) 

Your Regency Woodstove is not to be con-

nected to any air distribution duct.

Emissions from burning  wood or gas could 

contain chemicals known to the State of 

California to  cause cancer, birth defects 

or other reproductive harm.

NOTE:  In  Canada,  floor  protection  must 

extend 18" (450mm) to the front and 

8" (200mm) to each side and back 

of the stove.

MODULAR INSTALLATION OPTIONS

The following items are required when assembling your Regency Stove.  F2404M unit - the Rear Heat Deflector is supplied with the stove, but if 

you choose not to use it you must use the Airmate instead.  

Modular Part

Things to consider when choosing options:

F2404M
Airmate OR 
Rear Heat Deflector

Clearances are different. See the Minimum Clearance to Combustible Materials chart in the 

Installation section of this manual. Generally you can get closer clearances with the airmate 

than with the rear heat deflector..
Convection heat with Airmate vs. Radiant Heat with Rear Heat Deflector. The airmate pushes 

heat forward and into the room, the rear heat deflector deflects the heat upward. See installa

-

tion instructions.

F2404M, S2404M
Pedestal OR
Legs

There are no performance differences with either the pedestal or legs.  It is primarily a personal 

preference.  Legs can be either painted cast .
Leg installation requires the bottom shield. See installation instructions.

OPTIONS: These can be installed at time of installation or added later:
Modular Option

Things to consider when choosing options

Blower/Fan

Adding the blower will increase the area heated by the stove, it can move warm air beyond the room where the stove 

is installed. Installation instructions.

Ash Drawer Kit

Adding the Ash Drawer Kit makes cleaning ashes out of the stove easier and cleaner.  Installation instructions.

Screen Door

A simple add-on option that will allow you to enjoy the sound, warmth and view of an open fire.

Содержание F2404M

Страница 1: ...919 033c MODELS F2404M S2404M Freestanding Woodstove 05 18 17 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions...

Страница 2: ...e the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this...

Страница 3: ...F2404 Freestanding Wood Fireplace 3 3 Modular Parts...

Страница 4: ...d Heights For Woodstove Flue 16 Mobile Home Installation 17 Listed Components For Mobile Home Installation 18 Flue Baffle Secondary Air Tube Installation 18 Stainless steel smoke deflector adjustment...

Страница 5: ...EL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE...

Страница 6: ...00 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE DVL G...

Страница 7: ...ood Fireplace 7 7 dimensions F2404M UNIT DIMENSIONS Classic Door Contemporary Door ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO...

Страница 8: ...8 F2404 Freestanding Wood Fireplace 8 dimensions S2404M UNIT DIMENSIONS Classic Door Contemporary Door...

Страница 9: ...smically active areas Regency rec ommends that your unit is secured to the floor by using the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential ins...

Страница 10: ...irmate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S2404M Step Stove 15 381 mm 5 5 139 mm 4 1...

Страница 11: ...404M 36 914 mm Step Stove S2404M 36 914 mm Minimum Overall Depth Y of Floor Protector Residential Residential Mobile Home Alcove Unit C Vent Close Clearance Close Clearance Y Z Y Z Y Z Y Z Medium F240...

Страница 12: ...e rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before placing in...

Страница 13: ...okingwhendoorisopen and dirty glass It might be sufficient to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing ov...

Страница 14: ...for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the mini mum standards of the National Fire Protection Association NFPA by having it inspected by a professio...

Страница 15: ...imney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with...

Страница 16: ...ample b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA...

Страница 17: ...y system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobile Home at a location other than through the roof and exits at a...

Страница 18: ...ding Stove F2404M The unit arrives with the 2 baffles on the floor of the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below For Mobile Home units in...

Страница 19: ...olts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WAR...

Страница 20: ...nd boltsholdingthe2platestogetherfrominside the firebox 4 Push the ash plug into the hole inside the firebox and replace all the bricks except for the brick over the ash plug refer to the brick diagra...

Страница 21: ...itch Black Black High Black Low Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram Wire98gr eps updated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Grou...

Страница 22: ...avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour from...

Страница 23: ...ent ash dump for easy removal of ash refer to Modular Installation Options section Safety Precautions 1 Do not allow ashes to build up to the loading doors Onlyremoveasheswhenthefirehas died down Even...

Страница 24: ...g a clean stove and chim ney system Have the chimney cleaned before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require n...

Страница 25: ...Plate 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Spring Hinge Cap Nickel each...

Страница 26: ...8 Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 079 Spring Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Go...

Страница 27: ...20 249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle...

Страница 28: ...place 28 parts list Part Description 020 960 Brick Set Complete 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick...

Страница 29: ...F2404 Freestanding Wood Fireplace 29 29 notes...

Страница 30: ...6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found t...

Страница 31: ...size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage so...

Страница 32: ...codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the a...

Страница 33: ...n order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Det...

Страница 34: ......

Страница 35: ......

Страница 36: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________...

Отзывы: