background image

 

F2404 Freestanding Wood Fireplace

  |    31

31

warranty

All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof 

of purchase by you). All claims must be complete and provide full details as requested by FPI to receive 

consideration for evaluation.  Incomplete claims may be rejected. 

 

Replacement units are limited to one per warranty term.  Airtube and baffle replacements are limited to one 

replacement per term. 

 

Unit must be installed according to all manufacturers’ instructions as per the manual. 

 

All Local and National required codes must be met. 

 

The installer is responsible to ensure the unit is operating as designed at the time of installation. 

 

The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner’s manual.  As 

outlined below, the warranty may be voided due to problems caused by lack of maintenance.  

 

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit 

will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced 

at our discretion. No labor coverage is included with these parts 

 

Exclusions: 

This Limited Lifetime Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance 

or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), firebrick (rear, sides 

or bottom), door or glass gasketing, or any other additional factory fitted gasketing. 

 

Malfunction, damage or performance based issues as a result of environmental conditions, location, chemical 

damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney components 

(including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels (such as 

unseasoned cordwood, mill-ends, construction lumber or debris, off-cuts, treated or painted lumber, metal or foil, 

plastics, garbage, solvents, cardboard, coal or coal products, oil based products, waxed cartons, compressed pre-

manufactured logs), lack of regular maintenance and upkeep, acts of God, weather related problems from 

hurricanes, tornados, earthquakes, floods, lightning strikes/bolts or acts of terrorism or war, which result in 

malfunction of the appliance are not covered under the terms of this Limited Lifetime Warranty.  

 

FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications 

or upgrades will not be performed on existing appliances). 

 

This warranty does not cover dealer travel costs for diagnostic or service work.   All labor rates paid to authorized 

dealers are subsidized, pre-determined rates. Dealers may charge homeowner for travel and additional time 

beyond their subsidy. 

 

Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may 

void this warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or 

corroded within three (3) months of installation/purchase. 

 

Units which show evidence of being operated while damaged, or with problems known to the purchaser and 

causing further damages will void this warranty. 

 

Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty. 

 

Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this 

warranty. 

 

Freight damages for products or parts are not covered under the terms of the warranty. 

 

Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior 

authorization from FPI may void this warranty. 

 

 

Revision Date: December 2016 

Regency Wood Products Warranty 

 

Содержание F2404M

Страница 1: ...919 033c MODELS F2404M S2404M Freestanding Woodstove 05 18 17 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions...

Страница 2: ...e the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this...

Страница 3: ...F2404 Freestanding Wood Fireplace 3 3 Modular Parts...

Страница 4: ...d Heights For Woodstove Flue 16 Mobile Home Installation 17 Listed Components For Mobile Home Installation 18 Flue Baffle Secondary Air Tube Installation 18 Stainless steel smoke deflector adjustment...

Страница 5: ...EL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE...

Страница 6: ...00 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE DVL G...

Страница 7: ...ood Fireplace 7 7 dimensions F2404M UNIT DIMENSIONS Classic Door Contemporary Door ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO...

Страница 8: ...8 F2404 Freestanding Wood Fireplace 8 dimensions S2404M UNIT DIMENSIONS Classic Door Contemporary Door...

Страница 9: ...smically active areas Regency rec ommends that your unit is secured to the floor by using the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential ins...

Страница 10: ...irmate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S2404M Step Stove 15 381 mm 5 5 139 mm 4 1...

Страница 11: ...404M 36 914 mm Step Stove S2404M 36 914 mm Minimum Overall Depth Y of Floor Protector Residential Residential Mobile Home Alcove Unit C Vent Close Clearance Close Clearance Y Z Y Z Y Z Y Z Medium F240...

Страница 12: ...e rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before placing in...

Страница 13: ...okingwhendoorisopen and dirty glass It might be sufficient to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing ov...

Страница 14: ...for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the mini mum standards of the National Fire Protection Association NFPA by having it inspected by a professio...

Страница 15: ...imney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with...

Страница 16: ...ample b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA...

Страница 17: ...y system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobile Home at a location other than through the roof and exits at a...

Страница 18: ...ding Stove F2404M The unit arrives with the 2 baffles on the floor of the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below For Mobile Home units in...

Страница 19: ...olts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WAR...

Страница 20: ...nd boltsholdingthe2platestogetherfrominside the firebox 4 Push the ash plug into the hole inside the firebox and replace all the bricks except for the brick over the ash plug refer to the brick diagra...

Страница 21: ...itch Black Black High Black Low Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram Wire98gr eps updated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Grou...

Страница 22: ...avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour from...

Страница 23: ...ent ash dump for easy removal of ash refer to Modular Installation Options section Safety Precautions 1 Do not allow ashes to build up to the loading doors Onlyremoveasheswhenthefirehas died down Even...

Страница 24: ...g a clean stove and chim ney system Have the chimney cleaned before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require n...

Страница 25: ...Plate 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Spring Hinge Cap Nickel each...

Страница 26: ...8 Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 079 Spring Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Go...

Страница 27: ...20 249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle...

Страница 28: ...place 28 parts list Part Description 020 960 Brick Set Complete 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick...

Страница 29: ...F2404 Freestanding Wood Fireplace 29 29 notes...

Страница 30: ...6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found t...

Страница 31: ...size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage so...

Страница 32: ...codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the a...

Страница 33: ...n order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Det...

Страница 34: ......

Страница 35: ......

Страница 36: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________...

Отзывы: