background image

18     | 

F2404 Freestanding Wood Fireplace

18    |

installation

Install the air tube into the holes in the side 

channels. The notch goes on the right hand 

side with the air holes facing toward the door. 

Slide the tube into the left hand side, as far 

as possible and then bring it back into the 

hole on the right hand side until it locks into 

position.  If the tube will not slide in easily, 

simply use a pair of vise grips or pliers and 

tap it into place with a hammer.  A tighter fit 

will ensure the tube will not move when the 

unit is burning.

2)

  Slide the left baffle over the air tubes from 

1  6HS-18 

Chimney Length

1  6HS-RCS  Rain Cap (6PL-MPC)

SIMPSON DURA-PLUS

Qty.Part # 

Description

1  6DVL8693  Connector Kit

1  6DP-MH9096 Mobile Home Kit

ICC EXCEL 2100 

Qty.Part # 

Description

1  6CL48  

48" Chimney length (also in  

 

 

12", 18", 24" lengths.

1  6RC  

Rain Cap

1  6RCS 

Spark Screen (for rain cap)

1  6RDS/SQS  Round/Square support box

1  6VF 

Flashing

1  6UBA 

"Ultrablack" Close Clearance

  

Connector

Canadian Installations*

SECURITY S2100 (see above for details)

ICC EXCEL 2100 (see above for details)

SELKIRK SENTINAL CF

*The use of alternate pitch flashings, support 

box extensions, additional chimney lengths, and 

additional chimney bracing, may be used on each 

of the previously listed systems.  These parts 

though must be from the same system as listed, 

and must be a similar and/or complimentary part.

CAUTION: At no time use unlabelled 

parts, or substitute parts made for 

another chimney system.

Install as per chimney manufacturer's instal

-

lation instructions.

FLUE BAFFLE & 
SECONDARY AIR TUBE 
INSTALLATION

The flue baffle system located in the upper area 

of the firebox is removable to make cleaning 

your chimney system easier.  The baffles must 

be  installed  prior  to  your  first    fire. 

  Smoke 

spillage  and  draft  problems  may  occur  if  

the baffles are improperly positioned. 

 Check 

the position of the baffles on a regular basis as 

they can be dislodged if too much fuel is forced 

into the firebox.

Freestanding Stove
F2404M

The unit arrives with the  2 baffles on the floor 

of the firebox. 

1)

  If all 4 air tubes are installed continue on to 

Step 2), if not, follow the instructions below. 

For Mobile Home units installed in the U.S. the 

unit must be grounded using a #8 ground wire 

with approved termination and star washer.

LISTED COMPONENTS 
FOR MOBILE HOME 
INSTALLATION

The Regency F2404M and S2404M  Freestand

-

ing pedestal units are approved for installation 

in a Mobile Home if one of the following pipe 

systems is used. 

U.S. Installation*

METALBESTOS SSII

Qty. Part # 

Description

1  6DS-VK 

Connector Kit

1  6TMH 

Shield/Support

1  6TAF-6 

Flashing

1  6T-36 

Chimney Length

1  6T-18 

Chimney Length

1  6T-CT 

Rain Cap 

PRO-JET 3103

Qty.Part # 

Description

1  PV06-TK  Connector

1  CSB 

Shield/Support

1  RRS 

Radiation Shield

1 LFR03 

Flashing

1  SL3 

Chimney Length

1  SL1 

Chimney Length

1  RCSA 

Rain Cap

SECURITY ASHT

Qty.Part # 

Description

1  DL42A-6 

Connector Kit

1  6SS 

Shield/Support

1  6FAMH 

Flashing

1  6L3 

Chimney Length

1  6L1 

Chimney Length

1  CPE 

Rain Cap

SECURITY S2100

Qty.Part # 

Description

1  DL42A-6 

Connector Kit

1  6XSF 

Support

1  6XFA 

Flashing

1  6XL3 

Chimney Length

1  6XL18 

Chimney Length

1  6XCPE 

Rain Cap

METAL-FAB TEMP/GUARD 2100

Qty.Part # 

Description

1  6DWBK 

Connector

1  6TGRS 

Roof Support

1  6TGG36 

Chimney Length

1  6TGG12 

Chimney Length

1  6TGF 

Flashing

1  6TGC 

Rain Cap

AMERI-TEC HS

Qty.Part # 

Description

1  6DCC 

Connector

1  6HSRS-12  Roof Support 

 

 

(6PLRS-12-BK)

1  6F 

Flashing

1  6HS-36 

Chimney Length

the front and then push it to the  back. 

3) 

Tilt the left baffle up on top of the side chan

-

nel and it will leave enough room to position 

the right baffle  in the same manner as Step 

1) above. Then reposition the left baffle flat on 

the air tubes.  

4)  Important: push both baffles so they are 

tight against the side walls. 

Note:  When getting the chimney cleaned, 

push the baffles forward toward the 

front of the stove, this should leave 

sufficient access to the flue.  If it is 

not enough space then remove the 

middle air tube (reverse the procedure 

in step 1) above), and baffle and then 

replace everything when cleaning is 

completed.

Side View

Front View

Front View

Содержание F2404M

Страница 1: ...919 033c MODELS F2404M S2404M Freestanding Woodstove 05 18 17 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions...

Страница 2: ...e the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this...

Страница 3: ...F2404 Freestanding Wood Fireplace 3 3 Modular Parts...

Страница 4: ...d Heights For Woodstove Flue 16 Mobile Home Installation 17 Listed Components For Mobile Home Installation 18 Flue Baffle Secondary Air Tube Installation 18 Stainless steel smoke deflector adjustment...

Страница 5: ...EL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE...

Страница 6: ...00 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE DVL G...

Страница 7: ...ood Fireplace 7 7 dimensions F2404M UNIT DIMENSIONS Classic Door Contemporary Door ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO...

Страница 8: ...8 F2404 Freestanding Wood Fireplace 8 dimensions S2404M UNIT DIMENSIONS Classic Door Contemporary Door...

Страница 9: ...smically active areas Regency rec ommends that your unit is secured to the floor by using the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential ins...

Страница 10: ...irmate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S2404M Step Stove 15 381 mm 5 5 139 mm 4 1...

Страница 11: ...404M 36 914 mm Step Stove S2404M 36 914 mm Minimum Overall Depth Y of Floor Protector Residential Residential Mobile Home Alcove Unit C Vent Close Clearance Close Clearance Y Z Y Z Y Z Y Z Medium F240...

Страница 12: ...e rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before placing in...

Страница 13: ...okingwhendoorisopen and dirty glass It might be sufficient to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing ov...

Страница 14: ...for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the mini mum standards of the National Fire Protection Association NFPA by having it inspected by a professio...

Страница 15: ...imney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with...

Страница 16: ...ample b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA...

Страница 17: ...y system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobile Home at a location other than through the roof and exits at a...

Страница 18: ...ding Stove F2404M The unit arrives with the 2 baffles on the floor of the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below For Mobile Home units in...

Страница 19: ...olts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WAR...

Страница 20: ...nd boltsholdingthe2platestogetherfrominside the firebox 4 Push the ash plug into the hole inside the firebox and replace all the bricks except for the brick over the ash plug refer to the brick diagra...

Страница 21: ...itch Black Black High Black Low Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram Wire98gr eps updated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Grou...

Страница 22: ...avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour from...

Страница 23: ...ent ash dump for easy removal of ash refer to Modular Installation Options section Safety Precautions 1 Do not allow ashes to build up to the loading doors Onlyremoveasheswhenthefirehas died down Even...

Страница 24: ...g a clean stove and chim ney system Have the chimney cleaned before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require n...

Страница 25: ...Plate 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Spring Hinge Cap Nickel each...

Страница 26: ...8 Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 079 Spring Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Go...

Страница 27: ...20 249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle...

Страница 28: ...place 28 parts list Part Description 020 960 Brick Set Complete 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick...

Страница 29: ...F2404 Freestanding Wood Fireplace 29 29 notes...

Страница 30: ...6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found t...

Страница 31: ...size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage so...

Страница 32: ...codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the a...

Страница 33: ...n order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Det...

Страница 34: ......

Страница 35: ......

Страница 36: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________...