background image

12     | 

F2404 Freestanding Wood Fireplace

12    |

installation

Diagram 2

Diagram 3

STOVE ASSEMBLY  
PRIOR TO 
INSTALLATION

All units require either the pedestal or 4 legs at

-

tached to the base. The F2404M  stove requires 

either the Airmate or Rear Heat Deflector on top 

of the stove. Clearances to combustible materials 

vary depending on whether the airmate or rear 

heat deflector is installed, so be sure to check 

the Minimum Clearances, Installation section.

Airmate Assembly for F2404M

(850-105)

1)

  The airmate sits on top of the stove with 

the slots in the sides fitting over the curved 

deflector on the rear stove top. See diagram 

1. Discard the Rear Heat Deflector that is 

supplied with the unit, it is not required if the 

airmate is installed. 

2)

  Center the airmate and push it forward to the 

front of the stove. The back of the airmate 

should be level with the back and sides of 

the rear heat shield. See Diagrams 2 & 3.

Rear Heat Deflector
Assembly for F2404M

(815-555)

The rear heat deflector is supplied with the stove 

and must be installed unless the optional airmate 

has been selected. It stops the heat radiated 

from the flue collar from overheating the rear 

wall. The rear heat deflector is installed on top 

of the rear heat shield, as shown in Diagram 4.

Side Shield Adjustment

The left and right side shields are lowered for 

shipping and handling. It allows for a handhold 

on the top of the stove. Before placing in the 

Step Stove in its final position, the side shields 

must be raised. 

Loosen the screws on the rear on the stove (3 

per side), slide the side panel up as far as pos

-

sible and then secure by tightening the screws.

Side Shield

Diagram 1

Diagram  4

Pedestal Assembly
F2404M & S2404M

(020-925)

 

 

1)

  For easier assembly, tip the stove on its back 

(onto a soft surface to prevent scratching).

  

 

Hint:

 If you have chosen the Ash Drawer 

option, remove the ash dump cover plates 

(knockout)  before  attaching  the  pedestal. 

See page 17 "Ashdrawer Kit Installation".

2)

 

Important:

 Remove the blanking plate if 

 a)

    you are 

not

 installing outside combustion 

air or 

  b) 

outside air is to be brought in from the 

rear

 of the stove (see below).

3)

  Unscrew the 4 bolts in the under-side of the 

stove. Align the holes in the corners of the 

pedestal top with the corresponding holes 

in the base of the stove. Fasten using a bolt 

and washer for each corner.

4)

  Push the  

Regency logo 

into the two 

holes in the 

front bottom 

left corner of 

the pedestal 

cover plate.

  

Note:  Any paint touch up should be done 

prior to placing logo on pedestal.

5) 

If not using ash drawer, then cover plate must 

be installed. If using ash drawer, then disregard 

cover plate.

Содержание F2404M

Страница 1: ...919 033c MODELS F2404M S2404M Freestanding Woodstove 05 18 17 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions...

Страница 2: ...e the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this...

Страница 3: ...F2404 Freestanding Wood Fireplace 3 3 Modular Parts...

Страница 4: ...d Heights For Woodstove Flue 16 Mobile Home Installation 17 Listed Components For Mobile Home Installation 18 Flue Baffle Secondary Air Tube Installation 18 Stainless steel smoke deflector adjustment...

Страница 5: ...EL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE...

Страница 6: ...00 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE DVL G...

Страница 7: ...ood Fireplace 7 7 dimensions F2404M UNIT DIMENSIONS Classic Door Contemporary Door ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO...

Страница 8: ...8 F2404 Freestanding Wood Fireplace 8 dimensions S2404M UNIT DIMENSIONS Classic Door Contemporary Door...

Страница 9: ...smically active areas Regency rec ommends that your unit is secured to the floor by using the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential ins...

Страница 10: ...irmate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S2404M Step Stove 15 381 mm 5 5 139 mm 4 1...

Страница 11: ...404M 36 914 mm Step Stove S2404M 36 914 mm Minimum Overall Depth Y of Floor Protector Residential Residential Mobile Home Alcove Unit C Vent Close Clearance Close Clearance Y Z Y Z Y Z Y Z Medium F240...

Страница 12: ...e rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before placing in...

Страница 13: ...okingwhendoorisopen and dirty glass It might be sufficient to initiallytrywiththeminimumrequired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing ov...

Страница 14: ...for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the mini mum standards of the National Fire Protection Association NFPA by having it inspected by a professio...

Страница 15: ...imney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with...

Страница 16: ...ample b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA...

Страница 17: ...y system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobile Home at a location other than through the roof and exits at a...

Страница 18: ...ding Stove F2404M The unit arrives with the 2 baffles on the floor of the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below For Mobile Home units in...

Страница 19: ...olts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WAR...

Страница 20: ...nd boltsholdingthe2platestogetherfrominside the firebox 4 Push the ash plug into the hole inside the firebox and replace all the bricks except for the brick over the ash plug refer to the brick diagra...

Страница 21: ...itch Black Black High Black Low Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram Wire98gr eps updated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Grou...

Страница 22: ...avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour from...

Страница 23: ...ent ash dump for easy removal of ash refer to Modular Installation Options section Safety Precautions 1 Do not allow ashes to build up to the loading doors Onlyremoveasheswhenthefirehas died down Even...

Страница 24: ...g a clean stove and chim ney system Have the chimney cleaned before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require n...

Страница 25: ...Plate 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Spring Hinge Cap Nickel each...

Страница 26: ...8 Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 079 Spring Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Go...

Страница 27: ...20 249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle...

Страница 28: ...place 28 parts list Part Description 020 960 Brick Set Complete 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick...

Страница 29: ...F2404 Freestanding Wood Fireplace 29 29 notes...

Страница 30: ...6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found t...

Страница 31: ...size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage so...

Страница 32: ...codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the a...

Страница 33: ...n order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Det...

Страница 34: ......

Страница 35: ......

Страница 36: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________...

Отзывы: