58
|
Regency Excalibur
®
P90EX Direct Vent Gas Stove
maintenance
Troubleshooting
For proper control operations, the control module must be electrically connected to the gas valve and all the ignition wiring connectors plugged in. Gas valves
with an electric “ON/OFF” switch must have the switch set to “ON”.
The light on the control module provides a self-diagnosis indication.
IMPORTANT : Should any of these error codes or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician.
LED
Condition
OFF
Normal / Waiting for call of heat
One Red Flash
“Gas Selection” Error
Two Red Flashes
No Spark Detected
Three Red Flashes
False Flame Detected
Four Red Flashes
No Flame Detected
Six Red Flashes
Pilot valve connection error
Seven Red Flashes
Main valve connection error
Eight Red Flashes
Vacuum switch not detected (Not applicable)
One Red Flash every 10s
Low Voltage Error
Troubleshooting Flow Chart