Regency Excalibur
®
P90EX Direct Vent Gas Stove | 51
installation
Wiring Diagram with Optional Wall Thermostat
If any of the original wires as supplied with the appliance must be replaced, it must be replaced with CSA type SEW (200
o
C) or its equivalent.
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate as long as there are 4 AA batteries installed. However, a 120V A.C. power supply is needed for the fan/blower/lights operation.
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
This heater does not require a 120V A.C. supply for
operation. In case of a power failure, the remote
control/thermostat will continue to operate as long
as there are 4 AA batteries installed.
CAUTION:
Ensure that the wires do
not touch a hot surface and are away
from sharp edges.
WARNING:
Electrical Grounding
Instructions
This appliance is equipped with a
three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not
cut or remove the grounding
prong from this plug.
Note:
4 AA Batteries must be installed into the back
up battery compartment however for this unit to
operate when power is lost. See battery back up
instructions in this manual The fan and or lights
will not operate during a power outage.
MODULE
911-373
REMOTE
OVERRIDE
WALL SWITCH
910-363
RECEPTACLE
BOX
WIRE
911-400
WIRE
911-401-ASM
911-398
SPARK
MH3V
VALVE
911-380 NG
911-381 LP
TX580 REMOTE
911-387
BATTERY
PACK
911-395
3 METER
WIRE HARNESS
FAN
911-389-ASM
P90EX WIRING DIAGRAM
6.40 x 3.95”
DC 6V
ADAPTER
911-394
POWER
LINE IN
FUSE
1A / 250V
5x20 mm
RED
RED
RED
ORANGE
BLACK
GREEN
GREEN
BLACK
BROWN
WHITE
RED
BLACK
BLACK
AUX300
911-365
PILOT
911-396-ASM NG
911-397-ASM LP
FLAME DETECT
GROUND
AA
AA
AA
AA
FAN
910-331/P
BLACK
BLACK
911-399-ASM
911-037
GROUND
BLACK
WHITE
OPTIONAL
THERMOSTAT
A wall thermostat may be installed if
desired. Connect the wires as per the wiring
diagrams.
Note: Preferable if the thermostat is
installed on an interior wall.
Regency® offers an optional programmable
thermostat but any 250-750 millivolt rated non
anticipator type thermostat that is CSA, ULC or UL
approved may be used.
CAUTION
Do not connect the millivolt wall
thermostat wires to the 120V
wires
.
Содержание Excalibur P90EX
Страница 63: ...Regency Excalibur P90EX Direct Vent Gas Stove 63 notes ...
Страница 68: ...68 Regency Excalibur P90EX Direct Vent Gas Stove warranty ...
Страница 69: ...Regency Excalibur P90EX Direct Vent Gas Stove 69 notes ...
Страница 70: ...70 Regency Excalibur P90EX Direct Vent Gas Stove notes ...
Страница 71: ...Regency Excalibur P90EX Direct Vent Gas Stove 71 ...