operating instructions

How to Light & Maintain a 
Wood Stove Fire

WARNING:  To build a fire in ignorance 
or to disregard the information con-
tained in this section can cause serious 
permanent damage to the unit and void 
your warranty!!

Operating  
Instructions

With your unit now correctly installed and safety 
inspected by your local authority, you are now ready 
to start a fire.  Before establishing your first fire, it 
is important that you fully understand the operation 
of your draft control.

WARNING

Fireplace Stoves equipped with doors 
should be operated only with doors fully 
closed. If doors are left partly open, gas 
and flame may be drawn out of the fireplace 
stove opening, creating risks from both 
fire and smoke.

First Fire

When your installation is completed and inspected 
you are ready for your first fire.

THIS UNIT IS DESIGNED TO BURN SEASONED 
CORDWOOD ONLY. COAL AND BRIQUETTES 
ARE NOT APPROVED.

1.  Open firebox door and build a small fire using 

paper and dry kindling on the firebrick hearth, 

DO NOT USE A GRATE. CAUTION: DO NOT 
BUILD FIRE TOO CLOSE TO GLASS.

  Secure 

door on the firebox and wait a few minutes for 
a good updraft in the flue to establish the fire.  
(Leaving the door slightly open will help your 
fire start more rapidly.)

 

CAUTION:  Never leave unit unattended 
if door is left open.  This procedure is for 
fire start-up only, as unit may overheat 
if door is left open for too long.

2.  Add two or three seasoned logs to your  fire. 

Form a trench in the ash bed to allow air to 
reach  the  rear  of  the  firebox  prior  to  closing 
the door. Build fire slowly.

 

WARNING:  Never build a roaring fire in 
a cold stove.  Always warm your stove 
up slowly!

3.  During the first few fires, keep the combustion 

rate at a moderate level and avoid a large fire. 
Only after 5 or 6 such fires can you operate the 
stove at its maximum setting, and only after the 
metal has been warmed. Always build up the 
fire slowly.

4.  For the first few days, the stove will give off an 

odour from the paint. This is to be expected as 
the high temperature paint becomes seasoned. 
Windows and/or doors should be left open to 
provide  adequate  ventilation  while  this  tem-
porary condition exists. Burning the stove at a 
very high temperature the first few times may 
damage  the  paint.  Burn  fires  at  a  moderate 
level the first few days.

5.  Do not place anything on the stove top during 

the curing process. This may result in damage 
to your paint finish.

6.  During the first few days it may be more difficult 

to start the fire. As you dry out your firebrick 
and your masonry flue, your draft will increase.

7.  For those units installed at higher elevations or 

into sub-standard masonry fireplaces, drafting 
problems may occur. Consult an experienced 
dealer or mason on methods of increasing your 
draft.

8.  Some  cracking  and  popping  noises  may  be 

experienced  during  the  heating  up  process. 
These noises will be minimal when your unit 
reaches temperature.

Left - Open                Right - Closed

Outward - Open      Inward - Closed

Side Draft Control

Draft Control

Both the primary and air wash drafts are controlled 
by the control slide located on the front left side of 
the unit (when facing the unit). To increase your draft 
- slide to the left to open, and to decrease - slide to 
the right to close. The I2453M unit has a secondary 
draft  system  that  continually  allows  combustion 
air to the induction ports at the top of the firebox.  

Draft is the force which moves air from the appliance 
up through the chimney. The amount of draft in your 
chimney depends on the length of the chimney, local 
geography, nearby obstructions and other factors. 
Too much draft may cause excessive temperatures 
in the appliance. Inadequate draft may cause back 
puffing into the room and plugging of the chimney.

9.  Before opening your door to reload, open the 

by-pass damper  fully for approximately 10 to 15 
seconds until the fire has been re-established. 
This will minimize any smoking (spilling) back 
into the room. After loading wood and front door 
closed,  close the by-pass damper, push rod in.

10. All  fuel  burning  appliances  consume  oxygen 

during  operation.    It  is  important  that  you 
supply a source of fresh air to your unit while 
burning. A slightly opened window is sufficient 
for the purpose.  If you also have a fireplace 
in your home, a downdraft may be created by 
your Regency Stove causing a draft down your 
chimney. If this occurs, slightly open a window 
near your unit.

WARNING:  If the body of your unit, 
or any part of the chimney connector 
starts to glow, you are over firing.  Stop 
loading fuel immediately and close 
the draft control until the glow has 
completely subsided.

11. If you have been burning your stove on a low 

draft, use caution when opening the door.  After 
opening the damper, open the door a crack, and 
allow the fire to adjust before fully opening the 
door.

12. The controls of your unit or the air supply pas-

sages should not be altered to increase firing 
for any reason.

13. If you burn the unit too slowly or at too low a set-

ting your unit will not be operating as efficiently 
as it can.  An easy rule of thumb says that if your 
glass is clean, then your flue is clean and your 
exhaust is clean.  Burn the stove hot enough to 
keep your glass clean, you won't need to clean 
your flue as often.

Содержание Classic I2453M

Страница 1: ...ODEL I2453M Classic I2453M Wood Fireplace Insert 02 15 22 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com 0219WN026S Tested listed by ...

Страница 2: ... in a manner inconsistent with operating instructions in this manual or if elements are deactivated or removed CAUTION BURNUNTREATEDWOODONLY OTHERMATERIALSSUCHASWOODPRESERVATIVES METALFOILS COAL PLASTIC GARBAGE SULPHUR OR OIL MAY DAMAGE THE HEATER This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hard woods as...

Страница 3: ...stallation Into a Masonry Fireplace 8 Altering the Fireplace 8 Draft 8 Installing Your Insert 9 Stainless Steel Smoke Deflector Installation 10 Faceplate and Trim Installation 11 Flue Collar Removal and Installation 12 Fan Installation 14 Floor Protection 15 Flue Baffle Secondary Air Tube Installation 15 Glass Replacement 15 Wood Door Handle Assembly 16 Brick Installation 17 Seasoned Wood 18 opera...

Страница 4: ...SUR DES GRILLES MAIS LES DÉPOSER DIRECTEMENT SUR L ÂTRE RISQUE DE DÉGAGEMENT DE FUMÉE OU DE FLAMMES TOUJOURS GARDER LES PORTES COMPLÈTEMENT OUVERTES OU FERMÉES LORSQUE L APPAREIL FONCTIONNE DANS UNE MAISON MOBILE TOUJOURS GARDER LES PORTES BIEN FERMÉES LORSQUE L APPAREIL FONCTIONNE OUVRIR LA PORTE UNIQUEMENT POUR ALIMENTER LE FEU SI LES PORTES DU POÊLE RESTENT OUVERTES TOUJOURS UTILISER LE PARE ÉT...

Страница 5: ...10 7 8 276mm 8 7 8 225mm 3 7 8 97mm 35 891mm 31 1 8 792mm 22 558mm 20 3 4 528mm 20 3 4 526mm 21 3 8 542mm 5 3 8 137mm 5 5 8 141mm 17 433mm 8 1 8 205mm 2 3 8 60mm From back of faceplate not shown to fuel door opening 7 178mm From back of faceplate not shown to fuel door opening 7 178mm ...

Страница 6: ... for clear ance to combustibles Your hearth extension must be made from a non combustible material Extending 16 for US and 18 for Canada measured from the fuel loading door CLEARANCES ARE CRITICAL Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel and the facing is heat resistant orthepaintmaydiscolour Unit I2453M Adjace...

Страница 7: ...place insert or hearth heater 4 Your fireplace insert is heavy and requires two or more people to move it safely The insertcanbebadlydamagedbymishandling 5 If your existing fireplace damper control will becomeinaccessibleonceyouhaveinstalled your Regency Insert you should either remove or secure it in the open position 6 Inspect your fireplace and chimney prior to installing your insert to determi...

Страница 8: ...for any damage or flaws such as burnouts metal or refectory warping 3 Inspection to a minimum of NFPA 211 Level II is recommended All repairs must be made prior to installinganinsert Thefireplacemustbestructur ally sound and be able to support the weight of the solid fuel insert 4 The factory built chimney must be listed per UL 127 or ULC 610 M87 for all installations Install thermal protection as...

Страница 9: ...your hearth extension with a heavy blanket or carpet scrap during the installation Convection Grills The black convection grills are pre installed on this appliance If the optional nickel grills are being used remove the black grills and position the nickel grill on the inside body face side and fasten using the bolts washers and nuts provided 2 per side as shown in the diagrams Note The grill has...

Страница 10: ...h bolts and slide deflector upward and out Install new deflector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door o...

Страница 11: ...f the overall width If the difference is greater than this use the supplied washers to attain the required width 4 The unit may now be slid into final position and attached to the connection system 5 Once connection is made the insulation strips should be installed between the insert faceplates and the fireplace face 6 The faceplate top may now be installed with insula tion strip behind by alignin...

Страница 12: ...he side walls 6 Manoeuver the baffle above the air tube and slide out Side View Front View Front View 5 Lift the left baffle out from underneath the right baffle then lift out Remove the right baffle Note F2500 shown 7 Takea ratchetandremovethetwoboltsatbackinsideofthefirebox These bolts are used to secure the flue collar Keep these and washers for re install 8 Slide collar off the unit List of To...

Страница 13: ...r as shown in diagram 4 While sliding the unit into place pull on the rod to ensure that the flue adaptor is properly engaged See Diagram 5 Double check the adaptor is seated properly and the pull rod in the firebox locate the two holes lined up to the two holes on the adaptor 14 Use the two bolts washers and lock wash ers removed in step 7 and install them tight en down using the 1 2 socket to en...

Страница 14: ...erial No ______________________________ Fan Installation Thermo Switch Sensor 3 Ensure that the power cord is not in contact with any hot stove surfaces NOTE DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF UNIT 4 Push the Regency logo plate into the two holes in the front bottom left corner of the fan Do not turn fan ON until your insert has reached operating temperature or at least 30 minutes after ...

Страница 15: ...atwillwithstandthehighest heat that your unit will produce In the event that you break your glass by impact purchase your re placementfromanauthorizedRegencydealeronly Remove the door from the stove and remove the screwssecuringtheglassretainer Positiontheglass in the door make sure that the glass gasketing will properly seal your unit and replace the retainer it should rest on the gasket not the ...

Страница 16: ...check door to ensure there is still a tight seal Repeat steps if door seal is still not tight until a tight seal has been achieved The handle should be approximately in the 8 o clock position when door is fully closed Diagram 3 2 Place the door onto the hinges and then place the door handle through the opening on the door as shown in Diagram 2 Diagram 1 Diagram 2 Diagram 3 Nuts Cam Door Handle Was...

Страница 17: ...at more evenly Check to see that all firebricks are in their correct positions and have not become misaligned during shipping Install all firebricks if bricks were removed at install per the diagram below and place in their correct positions Do not use a grate 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 32mm x 114mm x 229mm 75 BrickPartial 1 1 4x4 1 2 x2 32m...

Страница 18: ...ods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possi...

Страница 19: ...u dry out your firebrick and your masonry flue your draft will increase 7 For those units installed at higher elevations or into sub standard masonry fireplaces drafting problems may occur Consult an experienced dealer or mason on methods of increasing your draft 8 Some cracking and popping noises may be experienced during the heating up process These noises will be minimal when your unit reaches ...

Страница 20: ...never burn flammable fluids such as gasoline naptha or engine oil in your stove 4 If you have smoke detectors prevent smoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney connector flue baffle or the stove top begin to glow you are over firing Stop adding fuel and close the draft control Over firing can cause extensive damage to your stove including warping and ...

Страница 21: ...nd chimney connector should be inspectedatleastonceeverytwomonthsduring the heating season to determine is a creosote buildup has occurred 6 Have chimney system and unit cleaned by competent chimney sweeps twice a year during the first year of use and at least once a year thereafter or when a significant layer of creosote has accumulated 3 mm 1 8 or more it should be removed to reduce the risk of ...

Страница 22: ...DS SUCH AS GASOLINE NAPTHA OR ENGINE OIL SOME FUELS COULD GENER ATE CARBON MONOXIDE AND ARE VERY DANGEROUS DO NOT BURN Treated wood Coal Garbage Cardboard Solvents Colored Paper Trash Salt drift wood Cut lumber plywood mill ends Burning treated wood garbage solvents colored paper or trash may result in release of toxic fumes Burning coal cardboard or loose paper can produce soot or large flakes of...

Страница 23: ... the two 7 16 bolts nuts to remove replace vertical deflector 3 Repeat steps to install new vertical deflector NOTE ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE TIGHT TO TOP OF FIREBOX Note that the unit is not exactly as shown 7 16 Nuts 7 16 Bolts Vertical Deflector Remove 2 front air tubes Slide right down to remove Reverse to replace ...

Страница 24: ...aper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti seize lube ie never seize Check glass for cracks Replace if required Clean blower motor Disconnect power supply Remove and clean blower DO NOT LUBRICATE Inspect and clean chimney Annual professional chi...

Страница 25: ...Carriage N S 181 085 P Vertical Stainless Deflector N S 021 022 Firebox Floor Gasket 948 223 Regency Logo Nickel 920 388 Manual Not available as a replacement part DETAIL M 24 28 29 42 7 23 20 1 18 36 37 22 21 42 2 4 9 17 16 19 6 27 Part Description 1 850 251 Door Assy Large Black 850 253 Door Assy Large Nickel Accent 2 846 308 Glass Replacement 4 936 241 7 8 Adhesive Tape Gasket 6 904 115 Screw 7...

Страница 26: ...gular 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 297 Trim Left Oversize 298 Faceplate Side Oversize 299 Faceplate Top Oversize Not available as a replacement part 285 286 287 288 288 289 REGULAR 296 295 297 298 299 298 OVERSIZE ...

Страница 27: ...1 1 4 x 4 1 2 x 9 32mm x 114mm x 229mm 75 Brick Partial 1 1 4 x 4 1 2 x 2 32mm x 114mm x 51mm 76 Brick Partial 1 1 4 x 2 x 9 32mm x 51mm x 229mm Duct Adaptor I2453M Part Description 80 946 001 Duct Collar Oval 81 946 002 Adaptor Round to Oval 946 002 946 001 PART Description 80 946 001 Duct Collar Oval 81 946 002 Adaptor Round To Oval ...

Страница 28: ...atalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s opti...

Страница 29: ...chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs kiln dried wood lack of regular maintenance ...

Страница 30: ...e above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain all warranty and service In the event the authorized selling dealer is unable to provide wa...

Страница 31: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANAD...

Страница 32: ...32 Regency I2453M 32 ...

Страница 33: ...Regency I2453M 33 33 notes ...

Страница 34: ...34 Regency I2453M 34 notes ...

Страница 35: ......

Страница 36: ...mation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial _________________________________________...

Отзывы: