ACV40E City Series
|
35
installation
102mm
Notes:
1. Liner sections should be continuous without any joints
or seams.
2. Only Flex pipe purchased from Regency
®
may be used
for Flex installations
3. Horizontal vent must be supported every 0.9m.
4. Regency
®
Direct Vent System (Flex) is only approved for
horizontal terminations.
5. Flex system can only be used up to a maximum continu-
ous vent length of up to 3m. If longer runs are required,
rigid pipe must be used.
Flueing Arrangements Horizontal Terminations
Flex Vent 102mm x 173mm
These flueing systems, in combination with the ACV40E Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system. The location
of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the ACV40E using a flexible vent.
FPI Kit #
Length
Contains:
#946-515
1.2m
1.
175mm flexible outer liner (Kit length)
2.
102mm flexible inner liner (Kit length)
3.
spring spacers
4.
thimble
5.
AstroCap
termination cap
6.
screws
7.
tube of Mill Pac
8.
plated screws
9.
S.S. screws #8 x 38mm drill point
#946-516
3m