background image

4

    | 

ACV40E City Series

data badge

Part #: 920-215 - Side 

A

Colours: Black on white,  except for parts indicated as being Red.    

   Punch out .25" hole top right corner where indicated.

Size: 

 

           100%

                         W

- 6.198" x L- 9.18"

                 Feb. 18/20:       Created decal March 2/20:

 

Updated serial and lighting plate decals.

Material:

 

Printable white polyester 7mm

Start serial sequence @ 000001

NOTE: This is a double sided decal

   

    

Part #: 920-215 - Side B

Colours: Black on white,  except for parts indicated as being Red.    

   Punch out .25" hole top right corner where indicated.

Size: 

 

           100%

                         w- 6.52"                          h- 1

1.13"

                 Feb. 18/20:     Created decal

Part #: 920-111d

Colour: Black on Grey

Size: 100% 7" W x 2.7" H

June10/19: Created decal

June 13/19: Removed -11 as per Daniela

Feb. 12/20: Updated gas consumption low value and injector size.

Feb. 19/20: Added label “Primarily a decorative and not a heating appliance” 

Mar. 2/20: Changed some consumption and pressure values.

Serial 

Number

 

Regency Gas Fireplace

527

Distributed by:

Western Australia:

                   Air Group Australia

                  28 Division St

                  Welshpool, WA 6106

Eastern Australia

                    

Fireplace Products

                  Australia Pty. Ltd. 

                  1 Conquest Way

                  Hallam, VIC 3803

New Zealand

                     Aber Holdings

                   17 Main Street Place

                   Te Rapa, HA 3200

To be installed by an authorised person in 

accordance with installation instructions 

provided with the appliance.

Electrical:   240V     50/60 Hz     

920-111d

Gas Type

NG                 Propane            ULPG

Model

ACV40ENG              ACV40ELP

   

ACV40EULPG

Gas Consumption High

  30 MJ/h                30 MJ/h                   24 MJ/h

Manifold Pressure High

0.96 kPa               2.60 kPa                   2.60 kPa

0.30 kPa               0.70 kPa                   0.63 kPa

Injector Size

 2.40 mm                1 x #53                      1 x #54

Approval No. GMK10594    

AS/NZS 5263.0 & AS/NZS 5263.1.8

Gas Consumption Low

   17.1 MJ/h            16.0 MJ/h                 11.7 MJ/h

Manifold Pressure Low

ACB40ENG              ACB40ELP

   

ACB40EULPG

Supply Pressure (Min.)

   1.13 kPa                 2.75 kPa                    2.75 kPa                 

 

                            1.51 mm                    1.39 mm

PRIMARILY A DECORATIVE AND NOT A 

HEATING APPLIANCE

920-214

Part #: 920-214

Colours: Black on Grey

,  except for parts indicated as being Red.

   

   Punch out .25" hole top right corner where indicated.

Size: 

 

           100%

                         w- 6.52"                          h- 1

1.13"

                 Feb 18/20:    Created decal Mar 2/20:

 

Added: "

SUIT

ABLE ONL

Y FOR INDOOR INST

ALLA

TION", removed French. 

DO NOT REMOVE THIS INSTRUCTION PLA

TE

SUIT

ABLE ONL

Y FOR INDOOR INST

ALLA

TION

This appliance must be installed in accordance with local codes, if any

. If none, follow the current 

AS/INZS 5601. 

CAUTION: Hot while 

in operation. 

Do not 

touch. 

Severe Burns may result. Due to high 

surface 

temperatures 

keep 

children, 

clothing 

and 

furniture, 

gasoline 

and 

other 

liquids 

having 

flammable 

vapors away

. Keep burner and control compartment clean. See installation 

and operating 

instructions accompanying

 appliance.

LIGHTING INSTRUCTIONS

FOR 

YOUR SAFETY

 READ BEFORE LIGHTING

W

ARNING: If you do not follow these instructions exactly

, a fire or explosion may result causing property damage,

 

personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause

 

injury or property damage. Refer to the owner

’s information manual provided with this appliance. For assistance

 

or additional information consult a qualified installer

, service agency

, or gas supplier

.

A)

 BEFORE 

LIGHTING 

smell 

all 

around 

the 

appliance 

area 

for 

gas. 

Be 

sure 

to 

smell 

next 

to 

the 

floor 

because 

some 

gas 

is 

heavier than air and will settle on the floor

.

WHA

T T

O DO IF 

YOU SMELL

 GAS

 

Do not try to light any appliance

 

-  

Do not touch any electric switch, do not use any phone in your building

 

-  

Immediately call your gas supplier from a neighbors phone. Follow the gas supplier

’s instructions.

 

-   

If you cannot reach your gas supplier

, call the fire department.

B)

 Do 

not 

use 

this 

appliance 

if 

any 

part 

has 

been 

under 

water

. Immediately 

call 

qualified 

service 

technician 

to 

inspect 

the 

appliance and to replace any part of the control system and any gas control which has been under water

.

This 

appliance 

needs fresh air 

for 

safe operation 

and 

must 

be 

installed 

so 

there are provisions 

for 

adequate 

combustion 

and ventilation air

.

ST

OP! Read the safety information above on this label.

 

1) Ensure the Main switch is in the ON position and/or the wall mounted battery holder (if equipped) is in the <REMOTE> positio

n.

2) Press and release the ON/OFF button on the remote handheld transmitter

. An audible beep should be heard from the receiver

. If not 

using the remote, the unit can also be turned on by sliding the battery holder switch to the <ON> position (if equipped).

3) 

After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner

.

 

4)  The unit will turn on.

Note: The first attempt to ignition will last approximately 60 s

econds. If there is no flame ignition (rectification) the board w

ill stop spark

-

ing for approximately 35 seconds. 

After this wait time, the board will start a second try for ignition by sparking for approximately 60 

seconds. If there is still no positive ignition after the second attempt the board will go into lock out. The system will need to be reset as follows (after going into lock out mode):

 

a)  

 W

ait 5 minutes - turn the system off by  pressing the ON/OFF butt

on on the remote.

 

b)  

 After approximately 2 seconds, press the ON/OFF button again.

 

c)  Unit will repeat step 2.

TO TURN OFF GAS 

APPLIANCE

1.

 

Press the ON/OFF button once.

2.

 

Turn off all electric power to the unit if service is to be perfo

rmed.

920-215

920-215

This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The data badge is located 
on the front inside base of the unit, visible when the outer front panel is removed.

NOTE: Regency

®

 units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of the Data Badge

Part #:  908-602c

Colour:  Black on White, expect what is indicated in yellow.

Size:     printed at 100%

July 18/17: Rev. C - Changed wording on Line 3 as per AGA - 

 

        removed Lines 4, 6 and 7 - updated caution  

 

        symbol size and font size to 10pt

May 7/14:   Changed wording on Line 3 as per AGA

Dec 12/12: Removed redundant ‘do not’ from the last line

Mar. 3/09:  Rev. A - added information

Nov. 6/06:  no changes to artwork.

DO NOT 

OPERATE THIS APPLIANCE BEFORE READING THE 

 

  INSTRUCTIONS BOOKLET.

DO NOT 

PLACE ARTICLES ON OR AGAINST THIS          

   

 

    APPLIANCE

DO NOT 

STORE CHEMICALS OR FLAMMABLE MATERIALS   

 

    NEAR THIS APPLIANCE.

DO NOT 

OPERATE WITH PANELS, COVERS OR GUARDS  

 

    REMOVED FROM THIS APPLIANCE.

908-602c

Содержание City New York View 40 Series

Страница 1: ...ervice must be performed by a qualified installer service agency or the gas supplier Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury death or property damage 920 110 03 03 20 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference LISTINGS...

Страница 2: ...r additional information co A BEFORE LIGHTING smell heavier than air and will s WHAT TO DO IF YOU SMELL Do not try to light any a Do not touch any electri Immediately call your ga If you cannot reach your B Do not use this appliance i appliance and to replace a This appliance needs fresh a and ventilation air 1 Ensure the Main switch is in t 2 Press and release the ON OFF using the remote the unit...

Страница 3: ...e Height Dimension may vary depending on the height of the leveling legs Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Страница 4: ...ening B2 Opening Height 383mm Bottom Top of Fireplace Opening C Sidewall on one side 216mm Side of Fireplace Opening D Mantel Depth max E Alcove Width 2134mm Sidewall to Sidewall Minimum F Alcove Depth 914mm Front to Unit Maximum G Ceiling in front of fireplace 953mm Top of Fireplace Opening H Convection Air Outlet Top of Enclosure J Convection Air Outlet Opening Offset 0 76mm Max offset from top ...

Страница 5: ...n in the diagram on the right Mantel Leg Clearances Combustible mantel leg clearances as per diagram 254 0 229mm 383mm 254 508 Top of Fireplace Opening 305mm 13mm Plasterboard timber timber panel etc To Bottomof Fireplace Opening 130mm 127 305mm 102mm Allowable mantel MANTEL LEG leg projection 178mm 216mm 51mm ACV40E ...

Страница 6: ...ning Height 51mm J Gas Connection Height 106mm K Gas Connection Inset 330mm L Gas Connection Opening Width 89mm Note A combined minimum of 774 square centimetres of open area is required for the convection air outlet to cool the enclosure Ensure clearances for Convection Air Outlets are met See clearances ACV40E single sided in this manual as there are different methods as to how this can be achie...

Страница 7: ...30 ACV40E City Series installation TV Recessed into Wall Maximum TV Recess TV Flush with Hearth ACB40E shown ACB40E shown ...

Страница 8: ...e 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Flueing Systems Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 0 9 metres Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is lower than t...

Страница 9: ...ex Vent 102mm x 173mm These flueing systems in combination with the ACV40E Direct Vent Gas Fireplace have been tested and listed as a direct vent heater system The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in Exterior Vent Termination Locations section Regency Direct Vent Flex System Termination Kits includes all the parts needed to ins...

Страница 10: ...ndoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 51mm When using Rigid Flue other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor WARNING Do not combine flueing components from different flueing systems However use of the the AstroCapTM and FPI Riser is acceptable with all systems Thisproducthasbeenevaluatedb...

Страница 11: ...can only be used up to 3m otherwise rigid flueing must be used Horizontal Flueing with Two 2 90o Elbows One 90o elbow Two 45o elbows Option V H H1 With these options maximum total pipe length is 9 1m with minimum of 1 8m feet total vertical and maximum 2 4m total horizontal Please note minimum 0 3mbetween90o elbows is required Min Max A 0 3m 0 6m B 0 6m 1 2m C 0 9m 1 5m D 1 2m 1 8m E 1 5m 2 1m F 1...

Страница 12: ...bow Vent must be supported at offsets Minimum distance between elbows is 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 1 2m Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position se...

Страница 13: ...over 10 12 to 11 12 0 99 over 11 12 to 12 12 1 22 over 12 12 to 14 12 1 52 over 14 12 to 16 12 1 83 over 16 12 to 18 12 2 13 over 18 12 to 20 12 2 29 over 20 12 to 21 12 2 44 Pipe Length Storm Collar Flashing Ceiling Firestop Rigid Pipe Adapter High wind cap This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct Vent Selkirk Direct Temp Ameri...

Страница 14: ...evel and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Vertical Flueing with Three 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V H H1 V V1 With these options max totalpipelength is 9 1m with min of 3m total vertical and max 2 4m total horizontal Please note min 0 3m between 90o elbows is required Min Max Min A 0 ...

Отзывы: