20
|
Regency Bellavista
®
B41XTE -11 Gas Fireplace
installation
Mantel Clearances
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
Due to the extreme heat this fireplace emits, the mantel clearances are critical.
Combustible mantel clearances from top of front facing are shown in
the diagram below.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-
combustible board. The non-combustible mantle when installed at a lower overall height may not be lower than 6 inches
from the top of the fireplace opening.
Mantel Clearances
B41XTE
A
B
C
D
Flush Safety Screen or Vi-
gnette/Vignette Trim Stepped Finish
From Top of
Fireplace Opening
35-1/4"
(895mm)
23-1/4"
(591mm)
19-1/2"
(495mm)
15"
(381mm)
Vignette with Vignette Finishing Trim
- Finished Flush
From Top of
Fireplace Opening
35-1/4"
(895mm)
33-1/16"
(825mm)
29-5/16"
(744mm)
24-9/16"
(624mm)
Note:
The Vignette Finishing trim can not be used in conjunction with the flush panels and Safety Screen
A separate 3 sided finishing trim is offered for this application.
To Base
of Unit
Flush Safety Screen or Vignette
Faceplate/Vignette Trim Stepped Finish
Vi Vignette finishing trim - finished flush