6 |
Regency CS1205 Freestanding Wood Stove
installation
RESIDENTIAL
INSTALLATION
1)
Read all instructions before installing your Re-
gency Stove. Install and use only in accordance
with these installation and operating instructions.
Be aware that local Codes and Regulations may
override some items in this manual. Check with
your local inspector.
2)
Select a position for your Regency Stove. Consult
the minimum clearance chart for your model and
set the stove in place. For close clearance instal-
lation use listed double wall connector systems
(refer to Combustible Wall Chimney Connector
Pass - Throughs).
3)
To insure vertical alignment, suspend a plumb
bob from the ceiling over the exact center of
your stove flue and mark a spot on the ceiling to
indicate the center of the chimney.
4)
Check that the area above the ceiling is clear for
cutting. Re-confirm the clearance from the stove
to combustibles to insure that they are within the
prescribed limits.
5)
Install chimney according to chimney manu-
facturers instructions. The performance of your
woodstove is governed to a very large part by the
chimney system. Too short a chimney can cause
difficult start-up, dirty glass, backsmoking when
door is open, and even reduced heat output. Too
tall a chimney may prompt excessive draft which
can result in very short burn times and excessive
heat output. The use of an inexpensive flue pipe
damper may be helpful in reducing excessive
draft.
CAUTION
: The chimney should be the same size
as the flue outlet on the stove. The chimney must
be listed as suitable for use with solid fuels. For
other types of chimneys check with your local build-
ing code officials. Do not confuse a chimney with a
type “B” Venting System used for gas appliances
as suitable for a wood burning appliance (refer to
the Mobile Home installations section).
6)
Mark the location of the unit base on the floor, then
move the stove aside and mark the position of the
floor protector.
7)
The floor protector must be of non-combustible
material and must extend 16" in front of the door
opening and 6" to the sides and rear of the unit.
Some areas may require a larger size floor protector.
See your local inspector. For outside air installation
refer to Mobile Home section.
8)
When the floor protection is complete, position the
stove with the flue collar centered under the installed
chimney.
9)
In seismically active areas, Regency recommends
that your unit is secured to the floor by using the
bolt down holes inside the pedestal (the same ones
used in Mobile Home installations).
10)
For residential installations using "C" Vent (single
wall) the chimney connector must be at least 24
gauge steel. Do not use galvanized pipe. For Mobile
Home installation refer to the Mobile Home instal-
lation section.
11)
Do not connect this unit to a chimney serving another
appliance unless approved by your local building
authority.
12)
A chimney connector cannot pass through an attic
or roof space, closet or similar concealed space,
or a floor, ceiling, wall or partition of combustible
construction. In Canada, if passage through a wall,
or partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365,
Installation Code for Solid-Fuel-Burning Appli
-
ances and Equipment.
13)
Your Regency Wood stove is not to be connected
to any air distribution duct.
ROOM AIR
IMPORTANT
Mobile home installations require the use of outside air.
See mobile home installation page for further details.
MODULAR INSTALLATION OPTIONS
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
NOTE: In Canada, floor protection must
extend 18" to the front and 8" to
each side of the stove.
OPTIONS: These can be installed at time of installation or added later:
Modular Option
Considerations when choosing options
Blower/Fan
Adding the blower will increase the area heated by the stove, it can move warm air beyond the room where the stove is installed.
Ash Drawer Kit
Adding the Ash Drawer Kit makes cleaning ashes out of the stove easier and cleaner.
Side Shields
Choice of black or stainless side shields. One set of side shields must be installed on unit.
Ashlip
To help contain displaced ashes.
Optional ember pro-
tection steel plate
Optional Ember Protection Floor Mat
Содержание Alterra CS1205
Страница 36: ...36 Po le bois autoportant Regency CS1205 garantie...
Страница 37: ...Po le bois autoportant Regency CS1205 37 notes...
Страница 38: ...38 Po le bois autoportant Regency CS1205 notes...
Страница 39: ...Po le bois autoportant Regency CS1205 39...
Страница 76: ......
Страница 77: ...Regency CS1205 Freestanding Wood Stove 37 notes...
Страница 78: ...38 Regency CS1205 Freestanding Wood Stove notes...
Страница 79: ......