Regada MP 52 200 Скачать руководство пользователя страница 13

MP 52 200

 

 

11 

After  receiving  of  the  EA  check  whether  during  their  transport  or  storing  no  damage 

occurred.  Compare  the  data  on  their  nameplates  with  the  accompanying  documentation/the 
purchase  agreement  (the  order).  In  case  of  any  discrepancy,  failure  or  damage  inform  about 
the fact the producer immediately. 

 

 

If not installed immediately the EA and their equipment should be stored in dry, well-conditioned 

sheltered areas, protected against impurities, dust and soil humidity (with keeping them on shelves or 
pallets),  chemical  and  unauthorized  impacts,  at  ambient  temperature  from  -10°C  to +50

°

C  and  at 

relative air humidity max. 80 %.  

 

a)  It is forbidden to store EA outside or in areas not prevented against direct impact of climate. 
b)  Strains  of  the  surface  finishing  should  be  promptly  removed  if  any  –  it  can  prevent the product 

against corrosion damages. 

c)  While storing more than one year it is necessary to check lubrication filling before the actuator is 

put into operation. 

d)  The EA installed but not operated are to be protected the same way as when storing (e.g. with a wrapping). 
e)  After  it  is  mounted  onto  a  valve  in  free  and  wet  areas  or  in  areas  where  temperature  is  changing  it  is 

necessary  to  connect  the  space  heater  –  to  prevent  the  actuator  against  corrosion  resulted  from  water 
condensed in the control part. 

f)  Remove odd conservation grease as late as before putting into operation.  

 

1.9  Liquidation of the Product and the Package 

The product is made of recyclable. The single parts of the package and the product should not 

be  thrown  away  after  its  lifetime  but  sorted  according  to  the  related  regulations  and  rules  about 
environment protection and delivered for next treatment. 

  The product itself as well as its package is not a source of spoiling of environment and they do 

not contain any dangerous waste. 
 
 

2.  Installation and Dismantling of the Actuator 

 
Follow safety regulations

 

Note:  
 

Check again whether the EA is place in accordance with the Chapter “Operation Conditions”. If the 

installation  conditions  are  different  than  recommended  it  is  needed  to  consult  the  situation  with  the 
producer. 

Before starting the installation onto the valve: 

· 

Check again whether the EA was not damaged while storing. 

· 

Check compliance of the stroke adjusted by the producer and the connecting dimensions of the EA 
with the parameters of the valve. 

· 

In case of any difference perform the adjustment according to the Chapter “Adjustment”. 

 

2.1.1  Mechanical connection 

 

EA  is  by  the  producer  adjusted  to  parameters  according  to  the  nameplate,  with  connecting 

dimensions according to the corresponding dimensional drawing and put it to a mid-position. 
 

Before installation put the handwheel on. 

 

Mechanical lever-joint connection 

· 

Properly defat contact surfaces of the EA, connecting flange and the valve/gearing. 

· 

Coat the valve/gearing output shaft firmly with a grease not containing any acid. 

· 

Reset the EA to the limit position "closed"; put the valve to the same limit position. 

· 

Put the EA onto the valve to have the output shaft reliably in the valve/gearing coupling. 

· 

Use the handwheel to turn the EA if needed to reach compliance between holes in the EA flange 

and the valve. 

!

Содержание MP 52 200

Страница 1: ...74 0767 02 Electric part turn actuators MP 52 200 INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS...

Страница 2: ...ng diagram Operation time s 90 Operation angle Transmitter potentiometer Serial number of electric motor Serial number of transmitter Serial number of position controller Tests made in accordance with...

Страница 3: ...7 Specifications 8 1 8 Packaging Transport Storing and Unpacking 10 1 9 Liquidation of the Product and the Package 11 2 Installation and Dismantling of the Actuator 11 2 2 Dismantling 12 3 Adjusting...

Страница 4: ...Operation Conditions and regarding its exposure rate is designated as a device with high exposure rate group A when it is an electric device of the group A see Regulation of MPSvR Ministry of Work and...

Страница 5: ...y service is provided by the service department of the producer on the basis of a written claim While claiming it is advised to present the following basic data from the nameplate type and serial numb...

Страница 6: ...llution AF 2 with a possibility of influences of mechanical stress medium sinusoid vibrations with frequency in range 10 up to 150 Hz with shift amplitude of 0 15 mm for f fp and acceleration amplitud...

Страница 7: ...ule M3 a gearbox with a manual control mechanism The gear train is located in the case 1 The gears are placed on the output shaft 3 and they make up an independent assembly set The rim 44 with interna...

Страница 8: ...o the control board place into the control box a transmission unit of the control board a position an indication unit a torque unit a transmitter block space heater local position indicator electric c...

Страница 9: ...ig 5 Position unit 11 After loosen a nut of the position unit 51 is possible to rotate 53 54 56 57 The construction of position unit is designed so that transforming one of the cams it does not distur...

Страница 10: ...ends 29 The flange 27 is screwed onto the actuator box 1 penetrated With a shaft and on its free end the lever is mounted Fig 8 1 7 Specifications Basic Specifications are given in the table 1 1 7 1...

Страница 11: ...lue Adjustment of the capacitive transmitter the position open 20 mA the position close 0 4 mA Weight 27 up to 29 kg Lubrication grease HF 401 0 GLEITM m Gearbox oil PP 80 1 7 2 Mechanical Connection...

Страница 12: ...or message LED SYS mode error message LED Adjusters communication connector 2x calibrating and adjusting button Local position indication with position indicator visible through aperture in upper cove...

Страница 13: ...gle parts of the package and the product should not be thrown away after its lifetime but sorted according to the related regulations and rules about environment protection and delivered for next trea...

Страница 14: ...rection open Press the lever 42 in the direction to the output shaft what switches contacts 20 MO S1 and the actuator should stop Press the button SB1 closed on the control board The output shaft shou...

Страница 15: ...Y Fig 6 The used transmitter resistance is 100 W Switch the converter s power supply on Turn the adjusting trimmer ZERO Fig 6 to adjust the output current signal rate measured on the terminals 81 82 t...

Страница 16: ...ust be power supplied In opposite case it is not guaranteed disconnection of remote control after switching the mode switch to the mode LOCAL Fig 10 4 Service maintenance and troubleshooting 4 1 Servi...

Страница 17: ...upply the EA stops in the position where it was before the failure If needed the EA can be set only with the manual control the handwheel After restoration of power the EA is prepared for operation In...

Страница 18: ...16 MP 52 200 4 4 Wiring diagrams...

Страница 19: ...er 2 wire with power supply Z295 connection of 1 phase electric motor Z298 connection of torque and position switches and space heater Z299 connection of torque and position switches and space heater...

Страница 20: ...18 MP 52 200 4 5 Dimensional drawings...

Страница 21: ...MP 52 200 19...

Страница 22: ...20 MP 52 200...