Series S Spring Driven Hose Reels
Page 2
www.reelcraft.com
INSTALLATION INSTRUCTIONS
INSTALLING THE INPUT HOSE(S)
A flexible connection between the reel and
the source of supply is required to prevent
possible misalignment and binding.
Non-flexible connections will void the
warranty. The pressure rating of the inlet
hose must be equal to or greater than the
rating of the reel.
Using the appropriate approved hose and
fittings connect the supply line to the inlet
connection of the reel.
Ensure you use thread sealants where
applicable and permitted.
Never over-tighten or under-tighten
fittings.
Once connection has been made to the
inlet of the reel ensure you make or fit a
connection to the outlet of the reel (the
main hose) then turn the supply valve on
slowly and check for leaks.
Note:
Please refer to your local authority
for rules and regulations on the safe use
of compressed liquids, gases and fuel
gases.
HOW TO MOUNT THE REEL
The hose reels are fitted with an all posi-
tion locking system, which allows the reel
to operate in all positions. The reel is
supplied as standard with a mounting
system and brackets that allow ceiling
mounting or wall mounting - an optional
floor or under bench mount can be
purchased for other mounting positions.
The optimum height for wall mounting is
such that it allows the hose or cable to be
pulled at an upward or a downward angle
of no more than approximately 15° -
angles exceeding this can create undue
drag in operation and potentially cause
premature wear to the mouth opening of
the reel.
For wall mounting where heights above 9
feet are required we suggest the use of the
swivel mounting optional floor bracket.
Bolt the bracket to the wall and fix the reel
in position as you would for ceiling
mounting.
HOW TO USE THE REEL
Once you have mounted your reel and
made the inlet connection you are ready
for operation. In order to familiarize your-
self with the function of the reel stand as
close as possible to the reel, pulling the
hose slowly out you will note a clicking
noise. This is the locking pawl running
over the locking teeth or ratchet teeth.
As soon as you hear this noise stop pull-
ing and allow the hose to retract a little
and it will lock in position. If it won’t lock
allow the hose to retract back further then
pull it again slowly until you hear the first
one or two clicks stop pulling and allow
the hose to retract a small amount and it
will lock.
Now pull it out some more until you here
the next set of clicks and repeat the lock-
ing process. The hose will lock about
every 3 feet or 1 meter increments but
only after you have been pulling it with an
outward movement. The locking system is
designed so that the hose will never lock
when rewinding the hose.
Once you are familiar with the system you
won’t need to listen for the locking clicks,
as you will automatically know when and
where it will lock.
Never let the hose fly back uncontrolled
this can cause damage to property or
person.
Always keep a firm hold of the hose as it
is retracting back into the reel.
To rewind the hose pull it out about 1ft or
300mm and then allow it to retract back
while holding the hose. If you want to
stop the rewinding and lock it in position
again, pull some hose out until you hear
the clicking and allow it to retract a little
locking the hose in position.
Typical mounting
Fixed floor mount
Ceiling mount
#S261398
Wire frame stand
NOTE: The orientation of the wall brackets
is important. Please follow drawings.