TROUBLESHOOTING 

TROUBLE

CAUSE

REMEDY 

Does not start. Starts, but 

immediately stops. 

1. 

Power Failure

2. 

Large discrepancy between power source and voltage

3. 

Significant drop in voltage

4.  Motor Phase malfunction

5. 

Electric circuit connection faulty

6. 

Faulty connection of control circuit

7. 

Fuse blown

8. 

Faulty magnetic switch

9. 

Water is not at level indicated by float 

10.  Float is not at appropriate level

11.  Float defective

12.  Short circuit breaker is functioning

13.  Foreign matter clogging pump

14.  Motor burned out 

15.  Motor bearing a failure

1-3. Contact electric power company and devise counter 

measures

4. Inspect connections an magnetic switch 

5.Inspect electric circuit 

6.Correct wiring 

7. Replace with correct type of fuse

8. Replace correct type of magnetic switch

9. Raise water level

10. Move float to appropriate starting level

11. Repair or replace

12. Repair location of short circuit

13. Remove foreign matter

14. Repair or replace 

15. Repair or replace 

Operates, but stops after 

a while. 

1. 

Prolonged dry operation has activated motor protector and 

caused the pump to stop. 

2. 

High liquid temperature has activated motor protector and 

caused the pump to stop 

1. 

Raise stop water level

2. 

Lower liquid temperature 

Does not pump. 

Inadequate volume.

1. 

Reverse Rotation

2. 

Significant drop in voltage

3. 

Operating a 60Hz pump on 50Hz

4.  Discahrge head is high

5. 

Large piping loss

6. 

Low operating water level causes air suction

7. 

Leaking from discharge piping

8. 

Clogging of discharge piping

9. 

Foreign matter in suction inlet 

10.  Foreign matter clogging pump

11.  Worn impeller 

1. 

Correct rotation (operation 2,3)

2. 

Contact electric power company and devise counter 

meaures

3. 

Check nameplate

4.  Recalculate and adjust 

5. 

Recalculate and adjust 

6. 

Raise water level or lower pump

7. 

Inspect, repair

8. 

Remove foreign matter 

9. 

Remove foreign matter 

10.  Dissassemble and remove foreign matter 

11.  Replace impeller 

Over Current 

1. 

Unbalanced current and voltage

2. 

Significant voltage drop

3. 

Motor phase malfunction

4.  Operating 50Hz pump on 60Hz 

5. 

Reverse rotation

6. 

Low head, Excessive volume of water

7. 

Foreign matter clogging pump

8. 

Motor bearing is worn or damaged 

1. 

Contact electric power company and devise counter 

measure

2. 

Contact electric power company 

3. 

Inspect connections and magnetic switch 

4.  Check nameplate

5. 

Correct rotation (see page 7)

6. 

Replace pump with low head pump

7. 

Disassemble and remove foreign matter

8. 

Replace bearing 

Pump Vibrates; excessive 

operating noise. 

1. 

Shut off valve closed too far

2. 

Piping resonates 

3. 

Reverse rotation 

1. 

Open shut off (valve)

2. 

Improve pipe mounting

3. 

Correct rotation (see page 7) 

Содержание REG100

Страница 1: ...www reefe com au EXPLODED VIEW INSTRUCTION MANUAL P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER MODEL REG100 CODE 22122 DOMESTIC SEWAGE GRINDER PUMP ...

Страница 2: ...www reefe com au DOMESTIC GRINDER REG100 P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER PARTS LIST EXPLODED VIEW Refer next page for componentry listing ...

Страница 3: ... 25 Screw 4 Washer 26 Rubber 3 Holes 5 Screw 27 Cable Gland 6 Grinding Plate 28 Connector 7 Screw 29 Capacitor 8 Tripod 30 Earth Connector 9 Impeller 31 Washer 10 Mechanical Seal 32 Screw 11 Counterface 32b Screw 12 Pump Body 33 Cable Gland 13 O Ring 34 Sleeve Socket 14 Spacer 34b Stopper 15 Lip Seal 35 Cover 16 Ball Bearing 36 Tie Rod 17 Cotter 37 Screw 18 Motor Shaft 38 Handle 19 Ball Bearing 39...

Страница 4: ...ad and the ground lead Green Yellow Insulation Resistance must be in accordance with the applicable Australian Standard DANGER Do not conduct electrical work unless you are a licenced Electrician WARNING When installing the pump pay close attention to it s centre of gravity and weight If it is not lowered into place correctly it may fall and be damaged or cause injury When transporting the pump by...

Страница 5: ...e pin plug connect as described in the manufacturer s instructions When a single phase power source is used connect the leads to the control panel terminals as shown in the diagram making sure they do not become twisted together Be sure to use a dedicated power supply with a ground earth leakage circuit breaker POWER CABLE CAUTION If it is necessary to extend the power cable use a core size equal ...

Страница 6: ... property damage or death 1 Run the pump for a short time 3 10 minutes and confirm the following Using an ammeter clamp on type measure the operating current at the L1 and L2 phase leads on the terminal Countermeasure If the operating current exceeds the rated value pump motor overload may be a cause or there may be insufficient back pressure Make sure the pump has been installed under proper coni...

Страница 7: ... not supplied Note that some kinds of damage or looseness may require that the unit be dismantled for repairs Please consult with your nearest dealer Frequency Inspection Items MONTHLY Measure insulation resistance Reference resistance 1 or greater NOTE If the insulation resistance has become notably lower than previous inspection an inspection of the motor will be necessary Meaure operating curre...

Страница 8: ...stop water level 2 Lower liquid temperature Does not pump Inadequate volume 1 Reverse Rotation 2 Significant drop in voltage 3 Operating a 60Hz pump on 50Hz 4 Discahrge head is high 5 Large piping loss 6 Low operating water level causes air suction 7 Leaking from discharge piping 8 Clogging of discharge piping 9 Foreign matter in suction inlet 10 Foreign matter clogging pump 11 Worn impeller 1 Cor...

Страница 9: ...www reefe com au Ascento Group Australia AI 062020 P 1800 807 604 ...

Страница 10: ...motor housing or disassembling the pump housing except by a qualified technician e Pumping chemicals or corrosive liquids or flammable liquids f Pumping hot liquids Exceeding 35 Centrigrade g Using a generator for power supply h Operations that involve frequent starting This will lead to premature failure of the capacitor i Dry operation will destroy the pump seals and is not covered by warranty W...

Страница 11: ... of these pumps must be constructed to allow the owner to easily remove the pump for servicing and to easily remove the pump for replacement warranty replacement or upgrading Warranty replacement does not include costs of removal and re installation as we have no control over the method of installation 9 Before installing or servicing disconnect from the power supply 10 This pump is not to be used...

Отзывы: