Reefe REG100 Скачать руководство пользователя страница 3

www.

reefe

.com.au

DOMES

TIC GRINDER REG100

POSITION COMPONENT

MATERIAL

A

Motor Casing 

AISI 304 Stainless Steel

B

Shaft

AISI 420 Stainless Steel 

C

Impeller 

G25 Cast Iron 

D

Bolts and Nuts

AISI 304

E

Mechanical Seal 

Silicone Carbide 

POSITION COMPONENT

POSITION COMPONENT

1 Screw

23 Cover 

2 Washer 

24 O-Ring

3 Grinding Knife 

25 Screw

4 Washer

26 Rubber 3 Holes 

5 Screw

27 Cable Gland 

6 Grinding Plate

28 Connector 

7 Screw

29 Capacitor

8 Tripod

30 Earth Connector 

9 Impeller

31 Washer

10 Mechanical Seal

32 Screw

11 Counterface

32b Screw

12 Pump Body

33 Cable Gland 

13 O-Ring

34 Sleeve Socket 

14 Spacer 

34b Stopper

15 Lip Seal

35 Cover 

16 Ball Bearing 

36 Tie-Rod

17 Cotter

37 Screw

18 Motor Shaft 

38 Handle 

19 Ball Bearing 

39 Power Cable 

20 Wound Stator 

40 Cable Clamp

21 Motor Housing 

41 Screw

22 Spring 

42 Float 

COMPONENTS &

MATERIALS

D

A

B

C

E

Содержание REG100

Страница 1: ...www reefe com au EXPLODED VIEW INSTRUCTION MANUAL P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER MODEL REG100 CODE 22122 DOMESTIC SEWAGE GRINDER PUMP ...

Страница 2: ...www reefe com au DOMESTIC GRINDER REG100 P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER PARTS LIST EXPLODED VIEW Refer next page for componentry listing ...

Страница 3: ... 25 Screw 4 Washer 26 Rubber 3 Holes 5 Screw 27 Cable Gland 6 Grinding Plate 28 Connector 7 Screw 29 Capacitor 8 Tripod 30 Earth Connector 9 Impeller 31 Washer 10 Mechanical Seal 32 Screw 11 Counterface 32b Screw 12 Pump Body 33 Cable Gland 13 O Ring 34 Sleeve Socket 14 Spacer 34b Stopper 15 Lip Seal 35 Cover 16 Ball Bearing 36 Tie Rod 17 Cotter 37 Screw 18 Motor Shaft 38 Handle 19 Ball Bearing 39...

Страница 4: ...ad and the ground lead Green Yellow Insulation Resistance must be in accordance with the applicable Australian Standard DANGER Do not conduct electrical work unless you are a licenced Electrician WARNING When installing the pump pay close attention to it s centre of gravity and weight If it is not lowered into place correctly it may fall and be damaged or cause injury When transporting the pump by...

Страница 5: ...e pin plug connect as described in the manufacturer s instructions When a single phase power source is used connect the leads to the control panel terminals as shown in the diagram making sure they do not become twisted together Be sure to use a dedicated power supply with a ground earth leakage circuit breaker POWER CABLE CAUTION If it is necessary to extend the power cable use a core size equal ...

Страница 6: ... property damage or death 1 Run the pump for a short time 3 10 minutes and confirm the following Using an ammeter clamp on type measure the operating current at the L1 and L2 phase leads on the terminal Countermeasure If the operating current exceeds the rated value pump motor overload may be a cause or there may be insufficient back pressure Make sure the pump has been installed under proper coni...

Страница 7: ... not supplied Note that some kinds of damage or looseness may require that the unit be dismantled for repairs Please consult with your nearest dealer Frequency Inspection Items MONTHLY Measure insulation resistance Reference resistance 1 or greater NOTE If the insulation resistance has become notably lower than previous inspection an inspection of the motor will be necessary Meaure operating curre...

Страница 8: ...stop water level 2 Lower liquid temperature Does not pump Inadequate volume 1 Reverse Rotation 2 Significant drop in voltage 3 Operating a 60Hz pump on 50Hz 4 Discahrge head is high 5 Large piping loss 6 Low operating water level causes air suction 7 Leaking from discharge piping 8 Clogging of discharge piping 9 Foreign matter in suction inlet 10 Foreign matter clogging pump 11 Worn impeller 1 Cor...

Страница 9: ...www reefe com au Ascento Group Australia AI 062020 P 1800 807 604 ...

Страница 10: ...motor housing or disassembling the pump housing except by a qualified technician e Pumping chemicals or corrosive liquids or flammable liquids f Pumping hot liquids Exceeding 35 Centrigrade g Using a generator for power supply h Operations that involve frequent starting This will lead to premature failure of the capacitor i Dry operation will destroy the pump seals and is not covered by warranty W...

Страница 11: ... of these pumps must be constructed to allow the owner to easily remove the pump for servicing and to easily remove the pump for replacement warranty replacement or upgrading Warranty replacement does not include costs of removal and re installation as we have no control over the method of installation 9 Before installing or servicing disconnect from the power supply 10 This pump is not to be used...