ELECTRICAL WIRING
WARNING
PERFORMING ELECTRICAL WIRING
•
Electrical wiring should be performed by a qualified/licenced person in accord with all applicable regulations. Failure to observe this precaution not
only risks breaking the law but is extremely dangerous.
•
Incorrect wiring can lead to electrical leakage, electrical shock, fire, property damage, injury or death.
•
Always make sure the pump is equipped with the specified overload protectors and fuses or breakers, as required by law, so as to prevent electrical
shock from an electrical leak or pump malfunction.
•
The voltage, frequency and current rating are displayed on the name plate, please ensure that the power supply meets the requirements.
WARNING
GROUNDING
•
Do not use the pump without first earthing it properly. Failure to earth it can lead to electrical shock from an electrical leak or pump malfunction.
CAUTION
•
Do not attach the earth wire to a gas pipe, water pipe, lightening arrestor or telephone earth wire. Improper earthing can result in electrical shock.
WARNING
CONNECTING THE POWER SUPPLY
•
Before connecting leads to the terminal, make certain the power supply is turned off (circuit breaker, etc.), to avoid electrical shock, shorting, or
unexpected starting of the pump, leading to injury or death.
WARNING
•
Before inserting the power supply plug make certain the power supply is turned off (circuit breaker, etc.) to avoid electrical shock, shorting or
unexpected starting of the pump, leading to injury or death.
CAUTION
•
Do not use the pump with the power cable or plug connected loosely, which can result in electric shock, shorting, fire, injury or death.
•
Draw power from a dedicated power outlet. Sharing the outlet with other equipment may overheat the branch outlet and could result in a fire.
- When using a three pin plug, connect as described in the manufacturer’s instructions.
- When a single-phase power source is used, connect the leads to the control panel terminals as shown in the diagram,
making sure they do not become twisted together.
•
Be sure to use a dedicated power supply with a ground/earth leakage circuit breaker.
POWER CABLE
CAUTION
•
If it is necessary to extend the power cable, use a core size equal to or larger than the original. This is necessary not only for avoiding a voltage drop,
but to prevent a cable overheating which can result in fire, electrical leakage, electrical shock, injury and death. Refer to AS3000.
•
If a cable with cut insulation or other damage is submerged in the water, there is danger of water seeping into the motor causing a short. This may
result in damage to pump, electrical leakage, electrical shock, fire, injury or death.
•
Be careful not to let the power cable be cut or become twisted. This may result in damage to the pump, electrical leakage, electrical shock, fire, injury
or death.
•
If it is necessary to submerse the connection leads of the poewr cable in water, first seal the leads completely in a molded sleeve, to prevent electrical
leakage, electrical shock, fire, injury or death.
•
Do not allow power cable leads or power supply plug to become wet.
•
Make sure that the cable does not become excessively bent or twisted, and does not rub against a structure in a way that might damage.
ELECTRICAL CIRCUIT DIAGRAMS
E
U
V
a
b
d
E: Earth cord
Colour: yellow/green (green)
U: Power
Colour: Brown
V: Power Cord
Colour: Blue
SINGLE PHASE BELOW 1HP
(INCLUDE 1HP)
SINGLE PHASE ABOVE 1HP
E
U
a
V
E: Earth cord
Colour: yellow/green (green)
U: Power
Colour: Brown
V: Power Cord
Colour: Blue
C
THREE PHASES
E
U
V W
b
a
E: Earth cord
Colour: yellow/green (green)
U: Power
Colour: Brown/Orange
V: Power
Colour: Grey
W: Power
Colour: Black
THREE PHASE PUMPS must be connected to an external motor starter fitted with a contactor and overload. The nominal current of the motor starter must
correspond to the electrical data marked on the pump nameplate.