PRIOR TO INSTALLATION & OPERATION

The installer must consult a WHS supervisor and/or adhere to all relevant criteria and regulations. The Installer should consult an engineer for site 

assessment and correct installation methods.

When the pump is delivered, first perform the following checks. 

INSPECTION

While unpacking, inspect the product for damage during shipment, and make sure all the fasteners, clamps, etc. are tightened properly.

SPECIFICATION CHECK

Check the model number to make sure it is the product that was ordered. Be certain it is the correct voltage and frequency. 

PRODUCT SPECIFICATIONS

CAUTION

- Do not operate this product under any conditions other than those for which it is specified.

-Failure to observce this precaution can lead to electrical shock, electrical leakage, fire, water leakage, damage to property, injury and death. 

INSTALLATION

CAUTION

• 

Do not pump in liquids other than water, sewage, or chemically stable wastewater. Do not use pump in oil, salt water, flammable liquids, or organic 

solvents.

• 

Use with a power supply voltage 5% of the rated voltage. 

• 

Do not use in water temperatures outside the range of 0-35

˚

C. This can lead to failure, electrical leakage, shock or fire. 

• 

Do not use in the vicinity of explosive or flammable materials, or areas classified as hazardous.

• 

Use only in fully assembled state

NOTE: Consult your dealer or representative before using with any liquids others than those indicated in this document.

PREPARING FOR INSTALLATION

Before installing the pump at a work site, you will need to have the following tools and instruments ready.

• 

Insulation resistance tester

• 

AC Voltmeter

• 

AC ammeter (clamp on type)

• 

Bolt and nut tighteners 

• 

Power supply connection tools 

• 

Ensure adequate power supply is available

NOTE: Please read also instructions that come with each of the test instruments. 

CHECKS TO MAKE BEFORE INSTALLATION

When a three pin plug is used: 

Use the megohmeter to measure the insulation resistance between the cabtyre cable plug tips and ground.

When connection leads are used: 

With the megohmeter, measure the insulation resistance between each core lead and the ground lead (Green/Yellow.)

Insulation Resistance must be in accordance with the applicable Australian Standard.

**DANGER!** Do not conduct electrical work unless you are a licenced Electrician. 

WARNING

• 

When installing the pump, pay close attention to it’s centre of gravity and weight. If it is not lowered into place correctly, it may fall and be damaged 

or cause injury.

• 

When transporting the pump by hand, be sure to employ manpower commensurate with the weight of the pump. To avoid back injury when lifting the 

pump, bend the knees to pick it up rather than bending your back. 

CAUTION

• 

Do not under any circumstances install or move the pump by suspending it from the power cable. The cable may be damaged causing electrical 

leakage, shock, fire, injury and death.

1. 

Attach the hose to the hose coupling as far as it will go, then fasten it securely with the hose band. 

2. 

Avoid dropping the pump or other strong impact. Lift the pump by holding it firmly with both hands or by attaching a rope or chain to the handle. 

3. 

Install the pump in an upright position on a secure base. Ensure that the inlet to the pump is not blocked by sludge, mud, solids, plastic bags, rubbish. 

4.  Where a float switch is attached to the pump, ensure the float switch is free to operate without interfering with tank walls, pipe owkr etc.

5. 

A swing check non-return valve and isolating valve should be fitted to discharge pipe close to the pump but accessible to that it can be replaced. 

6. 

The pump must not be used in or at swimming pools, garden ponds, or where there are people in the water. 

CAUTION

• 

Avoid dry operation, which will not only lower performance but can cause the pump to malfunction, leading to electrical leakage and shock 

7. 

Install the pump in a location with sufficient water level, where water collects readily.

N

OTE: Please refer to “Operating Water Level” for the water level neccesarry for operation 

N

OTE: The discharge end should be located higher than the water surface. If the end of the hose or pipe is submerged, water may flow back to the pump 

when the pump is stopped; and if the hose end is lower than the water surface, water may overflow when the pump is turned off. 

CAUTION

• 

If large quantities of earth are sucked up, damage resulting from erosion in the pump can lead to electrical leakage and shock 

8. 

To prevent the pump strainer stand from becoming submerged in mud, causing it to suck in debris, mount it on a blaock or firm base 

Содержание REG100

Страница 1: ...www reefe com au EXPLODED VIEW INSTRUCTION MANUAL P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER MODEL REG100 CODE 22122 DOMESTIC SEWAGE GRINDER PUMP ...

Страница 2: ...www reefe com au DOMESTIC GRINDER REG100 P U M P S A U S T R A L I A BETTER FASTER EASIER BETTER FASTER EASIER PARTS LIST EXPLODED VIEW Refer next page for componentry listing ...

Страница 3: ... 25 Screw 4 Washer 26 Rubber 3 Holes 5 Screw 27 Cable Gland 6 Grinding Plate 28 Connector 7 Screw 29 Capacitor 8 Tripod 30 Earth Connector 9 Impeller 31 Washer 10 Mechanical Seal 32 Screw 11 Counterface 32b Screw 12 Pump Body 33 Cable Gland 13 O Ring 34 Sleeve Socket 14 Spacer 34b Stopper 15 Lip Seal 35 Cover 16 Ball Bearing 36 Tie Rod 17 Cotter 37 Screw 18 Motor Shaft 38 Handle 19 Ball Bearing 39...

Страница 4: ...ad and the ground lead Green Yellow Insulation Resistance must be in accordance with the applicable Australian Standard DANGER Do not conduct electrical work unless you are a licenced Electrician WARNING When installing the pump pay close attention to it s centre of gravity and weight If it is not lowered into place correctly it may fall and be damaged or cause injury When transporting the pump by...

Страница 5: ...e pin plug connect as described in the manufacturer s instructions When a single phase power source is used connect the leads to the control panel terminals as shown in the diagram making sure they do not become twisted together Be sure to use a dedicated power supply with a ground earth leakage circuit breaker POWER CABLE CAUTION If it is necessary to extend the power cable use a core size equal ...

Страница 6: ... property damage or death 1 Run the pump for a short time 3 10 minutes and confirm the following Using an ammeter clamp on type measure the operating current at the L1 and L2 phase leads on the terminal Countermeasure If the operating current exceeds the rated value pump motor overload may be a cause or there may be insufficient back pressure Make sure the pump has been installed under proper coni...

Страница 7: ... not supplied Note that some kinds of damage or looseness may require that the unit be dismantled for repairs Please consult with your nearest dealer Frequency Inspection Items MONTHLY Measure insulation resistance Reference resistance 1 or greater NOTE If the insulation resistance has become notably lower than previous inspection an inspection of the motor will be necessary Meaure operating curre...

Страница 8: ...stop water level 2 Lower liquid temperature Does not pump Inadequate volume 1 Reverse Rotation 2 Significant drop in voltage 3 Operating a 60Hz pump on 50Hz 4 Discahrge head is high 5 Large piping loss 6 Low operating water level causes air suction 7 Leaking from discharge piping 8 Clogging of discharge piping 9 Foreign matter in suction inlet 10 Foreign matter clogging pump 11 Worn impeller 1 Cor...

Страница 9: ...www reefe com au Ascento Group Australia AI 062020 P 1800 807 604 ...

Страница 10: ...motor housing or disassembling the pump housing except by a qualified technician e Pumping chemicals or corrosive liquids or flammable liquids f Pumping hot liquids Exceeding 35 Centrigrade g Using a generator for power supply h Operations that involve frequent starting This will lead to premature failure of the capacitor i Dry operation will destroy the pump seals and is not covered by warranty W...

Страница 11: ... of these pumps must be constructed to allow the owner to easily remove the pump for servicing and to easily remove the pump for replacement warranty replacement or upgrading Warranty replacement does not include costs of removal and re installation as we have no control over the method of installation 9 Before installing or servicing disconnect from the power supply 10 This pump is not to be used...