13

Accessories and Replacement Parts 

• 

FC-300

 Fused Test Lead Set

• 

R1000

 Safety Test Lead Set, Double Insulated

• 

CA-05A

 Soft Carrying Case

• 

C-820

 Soft Carrying Case

Don't see your part listed here? For a complete list of all accessories and 
replacement parts visit your product page on www.reedinstruments.com.

Product Care

To keep your instrument in good working order we recommend the following:
•  Store your product in a clean, dry place.
•  Change the battery as needed. 
•  If your instrument isn't being used for a period of one month or longer 

please remove the battery.

•  Clean your product and accessories with biodegradable cleaner. Do not 

spray the cleaner directly on the instrument. Use on external parts only.

Product Warranty

REED Instruments guarantees this instrument to be free of defects in 
material or workmanship for a period of one (1) year from date of shipment. 
During the warranty period, REED Instruments will repair or replace, at no 
charge, products or parts of a product that proves to be defective because 
of improper material or workmanship, under normal use and maintenance. 
REED Instruments total liability is limited to repair or replacement of the 
product. REED Instruments shall not be liable for damages to goods, 
property, or persons due to improper use or through attempts to utilize the 
instrument under conditions which exceed the designed capabilities. In 
order to begin the warranty service process, please contact us by phone at 
1-877-849-2127 or by email at [email protected] to discuss the 
claim and determine the appropriate steps to process the warranty.

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R5800

Страница 1: ...Voltage Current Simulator Instruction Manual R5800 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 2: ...Function 8 Output Operation Procedure 9 DC Voltage Output 9 DC Current Output 9 25 Step Current Output 10 Current Output Set for Zero Point Full Scale 10 Simulating Transmitter Output XMT 11 Battery Replacement 11 12 Fuse Replacement 12 Accessories and Replacement Parts 13 Product Care 13 Product Warranty 13 Product Disposal and Recycling 14 Product Support 14 REED Instruments 1 877 849 2127 info ...

Страница 3: ...nt the user and the instrument from electric shock and other hazards it is necessary to follow the following regulations Never attempt to repair or modify your instrument Dismantling your product other than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Do not opera...

Страница 4: ... 000 to 22 000mA 0 001mA 0 05 of set value 4μA Max load 1kΩ at 20mA note 1 Analog transducer 20mA 0 000 to 22 000mA 0 001mA 0 05 of set value 4μA Max load 1kΩ at 20mA Loop power 24V 10 Max output current up to 25mA Note 1 When the battery voltage exceeds 6 8V the max load is 1KΩ at 20mA When its voltage lies between 5 8V and 6 8V the max load is 700Ω at 20mA Note 2 Temperature coefficient 0 005 of...

Страница 5: ...r Yes Replaceable Test Leads Yes Product Certifications CE Operating Temperature 32 to 122 F 0 to 50 C Operating Humidity Range 0 to 85 Storage Temperature 14 to 122 F 10 to 50 C Dimensions 7 1 x 3 5 x 1 9 180 x 90 x 47mm Weight 8 2oz 500g Included Test Leads Alligator Clips Protective Holster Batteries REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 6: ...Output Value Setting Button 6 Output Digit Selection Button R5800 Voltage Current Simulator 3 4 5 6 7 8 9 10 7 Unit mA Select Button 8 Zero FS Points Select Button 9 25 Single Step Setting Auto Ramp Button 10 Output Terminals REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 7: ...on state denoting that the zero point or the full scale point is now in calibration Indicates that the battery power is low and needs to be replaced Indicates that the output digits need to be set V mA Indicates the current output value unit of measure Indicates that the output signal is on or off REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 8: ... the display 5 Press the button to toggle between AP ON AP OF AP OF indicates that the automatic power off function is disabled while AP ON indicates the automatic power off function is enabled 6 Press the mA 100 button to save the required setting 7 Press and hold the ON OFF button to exit the maintenance state and turn the instrument off Output Function The output terminal of the instrument can ...

Страница 9: ...ated by ON or OFF on the LCD display DC Current Output 1 Insert one end of the test leads into the mA output jack and connect the other end to the input of the meter as shown in the diagram 2 Press the V mA button to select mA function and mA will appear on the display 3 Press the mA button to select mA or function to display the mA or unit in which 0 is 4mA and 100 is 20mA 4 Press the buttons to ...

Страница 10: ...utton to exit the 25 current output setup Current Output Set for Zero Point Full Scale 1 Connect the test leads to the meter as stated in the Current Output procedures 2 Press the V mA button to select the mA function and mA will appear on the display 3 Press the mA 100 button 0 and FS will appear on the display 4 Press the mA button to select the set output mA or and mA or mA will appear on the L...

Страница 11: ...der to prolong battery life Battery Replacement When the appears on the LCD the batteries need to be replaced Follow the instructions below to properly replace the batteries 1 Turn the power off the meter and remove any test leads that may be attached to the meter 2 Lift the tilt stand on the back of the unit to access the battery compartment door which can be removed using a Phillips head screwdr...

Страница 12: ...eration wait 5 seconds before turning meter on after changing batteries Fuse Replacement 1 Remove the test leads from the meter and turn the meter OFF 2 Take off the protective boot Figure 1 remove the four screws by using a standard blade screwdriver and then remove the cover Figure 2 3 Replace the blown fuse s 4 Reinstall the cover 5 Reinstall the meter s protective boot Figure 1 Figure 2 REED I...

Страница 13: ...uments guarantees this instrument to be free of defects in material or workmanship for a period of one 1 year from date of shipment During the warranty period REED Instruments will repair or replace at no charge products or parts of a product that proves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repai...

Страница 14: ...EED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unauthorized copying or reproduction of this manual is strictly prohibited without prior wri...

Страница 15: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 16: ...REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Отзывы: