Maintain a clearance of at least 10 ft (3 m) between any part of the
machine and its occupants, their tools and their equipment from
any electrical line or apparatus carrying up to 50,000 volts. 1 ft (.3 m)
additional clearance is required for every additional 30,000 volts or less.
x
The minimum safe approach distance may be reduced if insulating
barriers are installed to prevent contact, and if the barriers are rated for
the voltage of the line being guarded. These barriers shall not be part
of (or attached to) the machine. The minimum safe approach distance
shall be reduced to a distance within the designed working dimensions
of the insulating barrier. This determination shall be made by a
qualified person in accordance with employer, local or governmental
requirements for work practices near energized equipment.
DO NOT MANEUVER MACHINE OR PERSONNEL INSIDE PROHIBITED ZONE
(MAD). ASSUME ALL ELECTRICAL PARTS AND WIRING ARE ENERGIZED
UNLESS KNOWN OTHERWISE.
Tipping Hazards
x
Be sure the bearing
surface is solid,
stationary and capable
of supporting the
intended load.
x
Before entering the
platform, ensure that
all outriggers have
been properly installed
and all leveling jacks
are fully extended and
bearing weight.
x
Check to be sure
the chassis is level
according to the bubble level indicator on the chassis and all wheels
are completely off the ground. Note: the platform will not release from
its docked position unless each outrigger is in its proper position, fully
extended and bearing weight.
SECTI
ON
1
SAFETY PRECAUTIONS
DANGER
NOTICE
CAUTION
WARNING