PowerLift
by ReechCraft
12
•
Maintain a clearance of at least 3 m between any part of the machine
and its occupants, their tools and their equipment from any electrical line
or apparatus carrying up to 50,000 volts. 0.3 m additional clearance is
required for every additional 30,000 volts or less.
•
The minimum safe approach distance may be reduced if insulating
barriers are installed to prevent contact, and if the barriers are rated for
the voltage of the line being guarded. These barriers shall not be part
of (or attached to) the machine. The minimum safe approach distance
shall be reduced to a distance within the designed working dimensions
of the insulating barrier. This determination shall be made by a
qualified person in accordance with employer, local or governmental
requirements for work practices near energized equipment.
DO NOT MANEUVER MACHINE OR PERSONNEL INSIDE PROHIBITED ZONE
(MAD). ASSUME ALL ELECTRICAL PARTS AND WIRING ARE ENERGIZED
UNLESS KNOWN OTHERWISE.
Tipping Hazards
•
Be sure the bearing
surface is solid,
stationary and capable
of supporting the
maximum ground
load of 163 kg.
•
Before entering the
platform, ensure that
all outriggers have
been properly installed
and all leveling jacks
are fully extended and
bearing weight.
•
Check to be sure the
chassis is level according to the bubble level indicator on the chassis
and all wheels are completely off the ground. Note: the platform will
not release from its docked position unless each outrigger is in its
proper position, fully extended and bearing weight.
SECTION
1
SAFETY PRECAUTIONS
DANGER
NOTICE
CAUTION
WARNING