Mounting tips>>
Engage the convex section of the area viewfinder fixing
arms with the notches of the main unit, and insert and
mount the arms.
Alarm Creep
Mount the area plate so that an arrow of the plate
center section faces upward and the letter surface can
be seen.
Insert the area plate into the top and bottom grooves of
the area viewfinder until the plate is stopped by the ribs.
SIP-5030
F2 F3 F4 F5
E2 E3 E4 E5
D1 D2
D3 D4
D5 D6
C1 C2 C3 C4 C5 C6
B1
B2
B3 B4
B5
7
8
9
10
1
2
3
4
5
6
F1
F6
E1
E6
B6
5030
(521206)
SIP-00
E1
D1D2
E2
F1
F2
C1 C2
B1 B2
2
1
100 (521207)
Fine adjust the main unit angle in vertical and horizontal
direction by observing the target area through the area
viewfinder.
3
Locate the center circle of the area
plate on the center circle of the lens
of the area viewfinder, and check the
detection area pattern on the area
plate and the background image.
* Each letter on the area plate
corresponds to each mirror number
(see Step 8-2).
* You cannot observe mirror
numbers B to F and B6 to F6
(shown at right) of the SIP-5030
area plate through the inspection
window. Check them using the
walk tester.
Adjusting tips>>
If you experience any of the following, see Step 0.
F2 F3 F4 F5
E2 E3 E4 E5
D1 D2
D3 D4
D5 D6
C1 C2 C3 C4 C5 C6
B1
B2
B3 B4
B5
7
8
9
10
1
2
3
4
5
6
F1
F6
E1
E6
B6
5030
(521206)
F2 F3 F4 F5
E2 E3 E4 E5
D1 D2
D3 D4
D5 D6
C1 C2 C3 C4 C5 C6
B1
B2
B3 B4
B5
7
8
9
10
1
2
3
4
5
6
F1
F6
E1
E6
B6
5030
(521206)
•
•
•
(5)
Cautions>>
The area viewfinder is a supporting tool for detection
area adjustment.
After you have adjusted the detection area using the
area viewfinder, always check the area using the walk
tester.
Never look directly into the sun through the area
view finder.
After you have used the area viewfinder, store it away
from direct sunlight.
Securely tighten the adjustment screw that you have
loosened.
Connect the walk tester (optional) to the sensor unit, and
check that the detection area is correct.
REDWAVE
REDWAVE
MICROWAVE
REDWAVE
ALARM OUTPUT
CELL BATTERY
POWER
SUPPLY
FROM
SENSOR
POWER OFF
REDWAVE
PIR NEAR
REDWAVE
PIR FAR
MEGARED
FAR
MEGARED
NEAR
REDWALL
REDWIDE
WALKTESTER
REDWALL
REDWIDE
MEGARED
CONNECTION
SELECT
SWITCH
MODE
SELECT
SWITCH
POWER
SELECT
SWITCH
OPM-WT
1
When the power selector switch is turned to “POWER
SUPPLY FROM SENSOR” position after plugging
the cable into the walk tester connector, a continuous
beeping sound will be heard.
2
When a pedestrian first enters the detection area, the
strong and weak beeps will sound alternately.
3
When the entirety of a pedestrian’s body is detected, the
strong beep will sound continuously.
•
•
•
•
(6)
(7)
Fixing arms
Notch
Convex
section
Grooves
Ribs
Arrow
marking
1
To change the direction of the inspection
window, rotate the area viewfinder in a
horizontal direction until it clicks and stops.
2
Move your face close to the viewfinder
so that your eye comes within 5 mm of
the inspection window (lens surface).
For near area alarm output
For far area alarm output
Use at “REDWAVE ALARM
OUTPUT” position to
confirm far and near area
alarm output.
Power selector
switch
Use at “REDWALL” position.
For creep zone alarm output
F2 F3 F4 F5
E2 E3 E4 E5
D11 D2
D33 D44
D5 D66
C1 C2 C3 C44 C5 C6
1
B2
B3 B4
B5
7
8
9
10
1
2
3
4
5
6
F1
F6
E1
E6
B
5030
(521206)
6
B6
6
B
B
B1
E
E
11
Center circle of the lens
Center circle of the
area plate
The detection area is
inside the frame
border.
Invisible area
The sensor area is extended
over the street where a person
walks or a car drives.
Branches of a tree and grass
move when the wind blows.
Limit line of detection area
SIP5030_EN.indd 4
2009/03/18 9:28:31