OBSERVE THE FOLLOWING PRECAUTIONS WHEN INSTALLING:
1. Mount the Camera in a position where it cannot be be interfered with either intentionally or accidentally.
2. The mounting surface should be capable of supporting the weight of both the Camera and mounting brackets under
all expected conditions of load, vibration and temperature.
3. The mounting brackets should be fitted in accordance with instructions and should observe all appropriate safety
precautions & local building regulations.
4. Ensure the Camera is in the correct orientation, see FIG B above.
X-IP-SERIES USER MANUAL
1
1
INSTALLING THE CAMERA HEAD
1.1
PTZ CONFIGURATION – CONVERTING BALL CAMERA TO DOME CAMERA
The RVX Series can be mounted as a dome or ball PTZ configuration. To convert the dome to ball PTZ remove the M4
button head screws with 2.5mm allen key provided. See FIG A below.
1.2
ATTACHING CAMERA TO BRACKET
BRACKET INSTALLATION:
Fixings to the various bracket types will depend on the fixing surface. It is important to use adequate quality fixings to
safely support the complete Dome/Ball PTZ assembly. Fixing slots on a 4” PCD provide adequate clearance for 6mm
bolts if attaching the Pedestal or Swan Mount to the mast.
FLYING LEAD:
If using a Swan/Pedestal/Pendant Mount, install the Fly Lead optionally through the Central Mounting Tube or via a
20mm Gland Entry Point. The Gland Entry is supplied with a 20 x 1mm thread to accomodate industry standard
20mm Glands.
FIG B MOUNTING ORIENTATION
Содержание RVIP Series