Redvision RVIP Series Скачать руководство пользователя страница 22

X-IP-SERIES USER MANUAL

18

•  

AF Sensitivity - In 'LOW' sensitivity mode, the camera requires a larger focus error before triggering an auto-focus
action - this prevents the camera from continuously refocussing ('focus hunting') in certain situations.

•  

Aperture (Edge/Sharpness Enhance) – Select the degree of edge enhancement (sharpness) the camera applies to the
video image.

•  

Defog - When selected, tries to compensate for fog or mist in the camera image by digital post processing.

•  

Exposure Compensation - Adjust the default exposure setting of the camera to lighten or darken the typical image
produced. A range of -7 to +7 'stops' is allowed. One 'stop' represents one step in the shutter speed, or lens aperture
setting.

•  

Gamma - Selects the colour compensation curve used by the camera, between 'Standard' and 'Straight' curves.

•  

High Res - Set the video output to enhance the fine detail contained.

•  

High Sensitivity - Setup the camera to give the highest light sensitivity possible, may produce a more grainy picture.

•  

Noise Reduction - when selected, the output video is processed to remove speckling and noise under low light
conditions. The setting may be applied differently in moving and parked situations.

•  

White Bal - Adjusts the colour palette of the video picture to suit different lighting conditions. Auto Tracing modes will
automatically compensate for changing lighting levels.

•  

Colour/Mono Effect - Sets the output video picture to colour or monochrome. This is only effective when IR Cut Filter
is set to 'Visible Light' mode. It has no effect when operating the camera in infra-red mode.

•  

Crosshair - Applies a 'gunsight' crosshair to the output video image.

6.6.1.2 

VIDEO STREAMING PROFILES

Set up the camera streaming settings to suit operational requirements. Up to three streams may be generated in various
resolutions and formats. Due to hardware limitations, not all combinations of encoder type and image size are available. 
Output bandwidths for each stream may be adjusted individually to suit quality and network requirements. 

Stream 1 bandwidth may be adjusted between 500kbps and 8000kbps

Streams 2/3 may be adjusted between 64kbps and 4000kbps

In MJPEG streams, bandwidth selection is accomplished by selecting a target image quality, in the range 5 – 98%

The RTSP port numbers for each stream may be changed from the camera default if required. This is most useful for 
clients which expect a primary RTSP stream on port 554. The port numbers selected will be reflected in the stream URI 
links provided via the web interface, and via the ONVIF control interface. A system reboot will be required.

Note : Each stream number must be unique. The RVIP dome does not currently support composite streams supplying 
multiple video channels within a single stream.

The default port numbers as delivered are 8557 for Stream 1, 8555 for Stream 2, and 8556 for Stream 3.

6.6.2 ADMIN 

FUNCTIONS

6.6.2.1 NETWORKING 

CONFIGURATION

Set the network configuration to suit the local installation requirements. Be aware that choosing invalid settings here 
may render the camera unuseable until re-configured locally.

6.6.2.2

USER ACCOUNTS & PERMISSIONS

6.6.2.2.1  ADD USERS

Create new user logins for camera, with various levels of authority.

6.6.2.2.2  EDIT/REMOVE USERS

Edit or delete existing camera user accounts.

6.6.2.3 

MAINTENANCE

The Maintenance menu includes tools to reset various camera configurations.

6.6.2.3.1 REBOOT CAMERA

Restarts the main camera software from a 'power on' state. This may be useful if the camera behaviour is incorrect 
after a configuration change.

6.6.2.3.2 RESET ONVIF PROFILES

Some DVR's and controllers can set conflicting configurations in ONVIF profiles. This option returns the ONVIF camera 
profile configurations to their default settings. A reboot operation will be required after using this option.

Содержание RVIP Series

Страница 1: ...ANUAL Products Covered RVIP SERIES PTZ Positioning Camera RVIP PSU Power Supply RVIP PSU ALM16 Power Supply with Alarm Module RVIP PSU ALM16 W PSU with Wireless PIR module RVIP v1 2 2015 Redvision CCT...

Страница 2: ...6 3 2 2 3 NETWORK CONNECTION 7 3 2 2 4 ALARM INPUTS 7 3 2 2 5 AUXILIARY OUTPUTS 7 3 2 3 FUSE PROTECTION 8 3 2 4 ALARM CONFIGURATION SWITCH SETTINGS 8 3 3 WIRELESS ALARM PSU RVIP PSU ALM W 8 3 3 1 RVI...

Страница 3: ...ARMS 15 6 4 2 1 ALARM BOARD 15 6 4 2 2 WIRELESS ALARMS 15 6 5 CONFIGURE CAMERA 15 6 5 1 BASIC CONFIG 15 6 5 1 1 CAMERA TITLE 15 6 5 1 2 MOUNTING ORIENTATION 15 6 5 1 3 INSTALLATION NOTES 15 6 5 1 4 TI...

Страница 4: ...X IP SERIES USER MANUAL 7 WEB BROWSER CONFIGURATION 20 7 1 JAVASCRIPT 20 7 2 VIDEO STREAMING PLUGIN 20 8 TECHNICAL SPECIFICATION 22 9 WARRANTY INFORMATION 23...

Страница 5: ...ONVERTING BALL CAMERA TO DOME CAMERA The RVX Series can be mounted as a dome or ball PTZ configuration To convert the dome to ball PTZ remove the M4 button head screws with 2 5mm allen key provided Se...

Страница 6: ...4 If RVIP PED Pedestal is being used support the Camera with hand when tightening the Hand Lock Nut ensure the Hand Lock Nut is fully tightened 5 Ensure the Clearance is even throughout 360 rotation a...

Страница 7: ...T ALL POWER BEFORE OPENING OR WORKING ON THE POWER SUPPLY UNIT INSTALLATION MUST BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON The Redvision power supply part code RVIP_PSU outputs 24V DC is supplied...

Страница 8: ...nection via terminal screw WIRE COLOUR SIGNAL PSU CONNECTOR PIN NO 1 Orange Camera TxN Transmit Data negative 3 2 Orange White Camera TxP Transmit Data positive 4 3 Blue Camera RxN Receive Data negati...

Страница 9: ...y installation cabling Due to the multiple interconnections required for the PTZ unit and power supply the maximum specified cable run from the PSU to network hub or switch is 50m For longer cable run...

Страница 10: ...H C CO ON NN NE EC CT TI IO ON NS S A AR RE E S SE EC CU UR RE EL LY Y S ST TR RA AI IN N R RE EL LI IE EV VE ED D PIN NO PCB IDENT WIRE COLOUR SIGNAL 1 TxN Blue PSU TxN Camera RxN 2 TxP Blue White PS...

Страница 11: ...B and connected to the PSU ground 3 2 2 5 AUXILIARY OUTPUTS Three sets of NO NCAuxiliary Output contacts are provided ALARM AUX WASH Each set of contacts are isolated and useable for any circuit withi...

Страница 12: ...en operation and OFF for Normally Closed NOTE Where fitted it may be necessary to remove the Wireless add on card in order to gain access to the S2 switch for configuration Ensure that power is discon...

Страница 13: ...ECTIONS ADDITIONAL 3 3 1 1 ANTENNA CONNECTOR BNC Connector 50Ohm type 3 3 2 CONFIGURING WIRELESS ALARM MODULE 3 3 2 1 DIP SWITCH SETTINGS 3 3 2 2 AERIAL 3 3 2 2 1 POSITIONING OF RVIP PSU ALM16 W To ma...

Страница 14: ...169 254 69 65 NOTE The Redvision IP Camera Discovery Tool can be used to calculate Local Link default addresses from a camera MAC address or Serial Number OTHER THIRD PARTY DOWNLOADS ARE AVAILABLE SUC...

Страница 15: ...PCs one suitable free option is DHCP Server for Windows from http www dhcpserver de No specific setup help can be offered here as each software will be different but usually setting a pool range of on...

Страница 16: ...med via the web interface using a direct connection from a PC to the RJ45 socket in the power supply module The camera may also be configured over the installation network 5 1 OPERATION VIA WEB INTERF...

Страница 17: ...lated to the normal operation of the camera view video streams PTZ control etc 6 1 1 1 VIEW CAMERA 6 1 1 1 1 LIVE STREAMING 6 1 1 1 1 1 STREAMING OFF Stop displaying video streams in the web interface...

Страница 18: ...OUR To edit a tour select the tour number from the sidebar the tour settings will be populated in the page 6 3 2 1 NAME Allows the user to set a name or description for the patrol tour 6 3 2 2 AUTO PO...

Страница 19: ...d date are correctly set A camera reporting incorrect date and time information may be rejected by a NVR or controller for security reasons Time and date may be automatically set from a network time s...

Страница 20: ...n or commence a predefined tour if there has been no manual control input for a period of time 6 5 2 2 CONTROL CONFIGURATION The Joystick Speed Scaling control adjusts the overall speed range for pan...

Страница 21: ...under joystick control Auto Focus Preset Tour Select if the camera should auto focus after moving to a preset or moving to each preset stage of a tour The camera will always move to the stored focus...

Страница 22: ...formats Due to hardware limitations not all combinations of encoder type and image size are available Output bandwidths for each stream may be adjusted individually to suit quality and network require...

Страница 23: ...tain more than one binary image If this is the case check the Release Notes document for any special instructions The firmware upgrade image file integrity should be checked before uploading to the ca...

Страница 24: ...or script blockers are disabled or the camers address is added to their whitelist Caution The following procedure if carried out incorrectly may prevent Firefox from working correctly Follow the instr...

Страница 25: ...Application dialog Click Choose and navigate to the VLC Media Player application This is probably located at Computer Local Disk C Program Files x86 VideoLAN VLC and called vlc exe Click Open then ti...

Страница 26: ...characters Preset titles 16 alphanumeric characters Privacy zones up to 16 available Alarm handling Weekend weekday time schedules for enabling disabling alarms Heater Yes Fan Yes ENVIRONMENTAL PHYSI...

Страница 27: ...iration of the above twenty four 24 month period whichever is later With respect to product not manufactured by Redvision to the extent permitted extends the warranties and affords the remedies to the...

Страница 28: ...X IP SERIES X IP SERIES USER MANUAL...

Отзывы: