8
WARNING: Disconnect all power to the unit before
installing option cards.
Adding Option Cards
The PAX2 can be fitted with up to three option cards. The details for each
option card can be reviewed in the specification section below. Only one card
from each function type can be installed at a time. The function types include
Setpoint Alarms (PAXCDS), Communications (PAXCDC), and Analog Output
(PAXCDL). The option cards can be installed initially or at a later date.
COMMUNICATION CARDS (PAXCDC)
A variety of communication protocols are available for the PAX2 Only one
PAXCDC card can be installed at a time.
Note: For Modbus communications
use RS485 Communications Output Card and configure communication (
tYPE
)
parameter for Modbus.
SERIAL COMMUNICATIONS CARD:
PAXCDC1_ and PAXCDC2_
Type
: RS485 or RS232
Communication Type
: Modbus ASCII, RLC Protocol (ASCII), and Modbus
RTU
Isolation To Sensor & User Input Commons
: 500 Vrms for 1 min.
Not Isolated from all other commons.
Data
: 7/8 bits
Baud
: 1200 to 38,400
Parity
: no, odd or even
Bus Address
: Selectable 0 to 99 (RLC Protocol), or 1 to 247 (Modbus
Protocol), Max. 32 meters per line (RS485)
Transmit Delay
: Selectable for 0 to 0.250 sec (+2 msec min)
DEVICENET™ CARD:
PAXCDC30
Compatibility
: Group 2 Server Only, not UCMM capable
Baud Rates
: 125 Kbaud, 250 Kbaud, and 500 Kbaud
Bus Interface
: Phillips 82C250 or equivalent with MIS wiring protection per
DeviceNet™ Volume I Section 10.2.2.
Node Isolation
: Bus powered, isolated node
Host Isolation
: 500 Vrms for 1 minute between DeviceNet™ and unit input
common.
PROFIBUS-DP CARD:
PAXCDC50
Fieldbus Type:
Profibus-DP as per EN 50170, implemented with Siemens
SPC3 ASIC
Conformance:
PNO Certified Profibus-DP Slave Device
Baud Rates:
Automatic baud rate detection in the range 9.6 Kbaud to 12 Mbaud
Station Address:
0 to 125, set by rotary switches.
Connection:
9-pin Female D-Sub connector
Network Isolation:
500 Vrms for 1 minute between Profibus network and
sensor and user input commons. Not isolated from all other commons.
SETPOINT CARDS (PAXCDS)
The PAX2 has 6 available setpoint alarm output option cards. Only one
PAXCDS card can be installed at a time. (Logic state of the outputs can be
reversed in the programming.) These option cards include:
DUAL RELAY CARD:
PAXCDS10
Type
: Two FORM-C relays
Isolation To Sensor & User Input Commons
: 2000 Vrms for 1 min.
Contact Rating
:
One Relay Energized: 5 amps @ 120/240 VAC or 28 VDC (resistive load).
Total current with both relays energized not to exceed 5 amps
Life Expectancy
: 100 K cycles min. at full load rating. External RC snubber
extends relay life for operation with inductive loads
QUAD RELAY CARD:
PAXCDS20
Type
: Four FORM-A relays
Isolation To Sensor & User Input Commons
: 2300 Vrms for 1 min.
Contact Rating
:
One Relay Energized: 3 amps @ 240 VAC or 30 VDC (resistive load).
Total current with all four relays energized not to exceed 4 amps
Life Expectancy
: 100K cycles min. at full load rating. External RC snubber
extends relay life for operation with inductive loads
QUAD SINKING OPEN COLLECTOR CARD:
PAXCDS30
Type
: Four isolated sinking NPN transistors.
Isolation To Sensor & User Input Commons
: 500 Vrms for 1 min.
Not Isolated from all other commons.
Rating
: 100 mA max @ V
SAT
= 0.7 V max. V
MAX
= 30 V
QUAD SOURCING OPEN COLLECTOR CARD:
PAXCDS40
Type
: Four isolated sourcing PNP transistors.
Isolation To Sensor & User Input Commons
: 500 Vrms for 1 min.
Not Isolated from all other commons.
Rating
: Internal supply: 18 VDC unregulated, 30 mA max. total
External supply: 30 VDC max., 100 mA max. each output
DUAL TRIAC/DUAL SSR DRIVE CARD:
PAXCDS50
Triac
:
Type
: Isolated, zero crossing detection
Voltage
: 260 VAC max., 20 VAC min.
Max Load Current
: 1 Amp @ 25°C
0.75 Amp @ 50°C
Total load current with both triacs ON not to exceed 1.5 Amps
Min Load Current
: 5 mA
Off State Leakage Current
: 1 mA max @ 60 Hz
Operating Frequency
: 20-400 Hz
SSR Drive
:
Type
: Two isolated sourcing PNP Transistors.
Isolation To Sensor & User Input Commons
: 500 Vrms for 1 min.
Not Isolated from all other commons.
Rating
:
Output Voltage: 18/24 VDC (unit dependent) ± 10%, 30 mA max.
total both outputs
QUAD FORM C RELAY CARD:
PAXCDS60
Type
: Four FORM-C relays
Isolation To Sensor & User Input Commons
: 500 Vrms for 1 min.
Contact Rating
:
Rated Load: 3 Amp @ 30 VDC/125 VAC
Total Current With All Four
Relays Energized not to exceed 4 amps
Life Expectancy
: 100 K cycles min. at full load rating. External RC snubber
extends relay life for operation with inductive loads
ALL SETPOINT CARDS
Response Time
: See Update Rates step response specification on page 6;
add 6 msec (typical) for relay card
LINEAR DC OUTPUT (PAXCDL)
Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available
from the analog output option card. The programmable output low and high
scaling can be based on various display values. Reverse slope output is possible
by reversing the scaling point positions.
ANALOG OUTPUT CARD:
PAXCDL10
Types
: 0 to 20 mA, 4 to 20 mA or 0 to 10 VDC
Isolation To Sensor & User Input Commons
: 500 Vrms for 1 min.
Not Isolated from all other commons.
Accuracy
: 0.17% of FS (18 to 28 °C); 0.4% of FS (0 to 50 °C)
Resolution
: 1/3500
Compliance
: 10 VDC: 10 K
W
load min., 20 mA: 500
W
load max.
Powered
: Self-powered
Update Response
: See Update Rates specification on page 6.
O
PTiOn
C
ards