PROGRAMMING MODE ENTRY (SEL BUTTON)

It is recommended all programming changes be made off line, or before 

installation. The meter normally operates in the Display Mode. No parameters 

can be programmed in this mode. The Programming Mode is entered by 

pressing and holding the 

SEL

 button. If it is not accessible then it is locked by 

either a security code, or a hardware lock.

MODULE ENTRY (SEL & RST BUTTONS)

The Programming Menu is organized into separate modules. These modules 

group together parameters that are related in function. The display will alternate 

between 

Pro

 and the present module. The 

RST 

button is used to select the desired 

module. The displayed module is entered by pressing the 

SEL

 button.

MODULE MENU (SEL BUTTON)

Each module has a separate module menu (which is shown at the start of each 

module discussion). The 

SEL

 

button is pressed to advance to a particular 

parameter to be changed, without changing the programming of preceding 

parameters. After completing a module, the display will return to 

Pro NO

Programming may continue by accessing additional modules.

SELECTION / VALUE ENTRY

For each parameter, the display alternates between the present parameter and 

the selections/value for that parameter. The 

RST

 button is used to move through 

the selections/values for that parameter. Pressing the 

SEL

 button, stores and 

activates the displayed selection/value. This also advances the meter to the next 

parameter.

For numeric values, press the 

RST

 button to access the value. The right hand 

most digit will begin to flash. Pressing the 

RST

 button again increments the 

digit by one or the user can hold the 

RST

 button and the digit will automatically 

scroll. The 

SEL

 button will advance to the next digit. Pressing and holding the 

SEL

 button will enter the value and move to the next parameter.

PROGRAMMING MODE EXIT (SEL BUTTON)

The Programming Mode is exited by pressing the 

SEL

 button with 

Pro NO

 

displayed. This will commit any stored parameter changes to memory and 

return the meter to the Display Mode. (If power loss occurs before returning to 

the Display Mode, verify recent parameter changes.)

PROGRAMMING TIPS

It is recommended to start with Module 1 and proceed through each module in 

sequence. When programming is complete, it is recommended to record the 

parameter programming and lock out parameter programming with the user input 

or programming security code.

FACTORY SETTINGS

Factory Settings may be completely restored in Module 2. This is useful 

when encountering programming problems.

ALTERNATING SELECTION DISPLAY

In the explanation of the modules, the following dual display with arrows will 

appear. This is used to illustrate the display alternating between the parameter 

on top and the parameter’s Factory Setting on the bottom. In most cases, 

selections and values for the parameter will be listed on the right.

6.0 p

roGraMMinG

 

the

 M

eter

Parameters

Output

Setpoint

Parameters

Signal Input

Pro

DISPLAY

MODE

Panel Key

Function

Parameters

3-dSP

Parameters

Display and Front

NO

SEL

RST

SEL

SEL

SEL

SEL

2-SEC

1-INP

4-SPt

5-SEr

SEL

Serial

Setup

Parameters

Secondary

OVERVIEW

PROGRAMMING MENU

Indicates Program Mode Alternating Display

Factory Settings are shown.

Parameter 

Selection/Value

BUTTON DISPLAY MODE OPERATION

ENTERING PROGRAM MODE

PROGRAMMING MODE OPERATION

SEL

Index display through enabled values

Press and hold for 2 seconds to activate

Store selected parameter and index to next parameter

RST

Resets values (MIN/MAX) or outputs

Advances through the program menu 

Increments selected parameter value or selection

OPERATING MODE DISPLAY DESIGNATORS

MAX

 

- Maximum display capture value

MIN

 

- Minimum display capture value

“1” - To the right of the display indicates setpoint 1 output activated.

“2” - To the right of the display indicates setpoint 2 output activated.

Pressing the 

SEL

 button toggles the meter through the selected displays. If display scroll is enabled, the display will toggle automatically every four seconds between 

the enabled display values. 

N0

USrIN

Содержание CUB 5P

Страница 1: ...n be powered from an optional Red Lion Micro Line Sensor Power Supply MLPS which attaches directly to the back of a CUB5 The MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the unit and sensors INPUT The CUB5P is a DC Process meter It features voltage and current input ranges that are selected by the user via a programming jumper and software input range selection The ranges ...

Страница 2: ...FICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A Safety requirements for electrical equipment for measurement control and laboratory use EN 61010 1 General Requirements EN 61010 2 030 Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component File E179259 UL Listed File E137808 Type 4X Indoor Outdoor ...

Страница 3: ...85 SERIAL COMMUNICATIONS CARD Type RS485 multi point balanced interface non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity Bus Address 0 to 99 max 32 devices per line Transmit Delay Selectable refer to CUB5COM bulletin RS232 SERIAL COMMUNICATIONS CARD Type RS232 half duplex non isolated Baud Rate 300 to 38 4k Data Format 7 8 bits odd even or no parity USB PROGRAMMING CA...

Страница 4: ...2010 1 07 Red Lion Controls LFIL0000 6 To protect relay contacts that control inductive loads and to minimize radiated and conducted noise EMI some type of contact protection network is normally installed across the load the contacts or both The most effective location is across the load a Using a snubber which is a resistor capacitor RC network or metal oxide varistor MOV across an AC inductive l...

Страница 5: ...N U S A MLPS1 2 WIRE TRANSMITTER COMM INP _ MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V DC COMMON M3424B TERMINAL AC INPUT RED LION CONTROLS YORK PA MADE IN U S A MLPS1 2 WIRE TRANSMITTER INP COMM EXTERNAL POWER COMM COMM VDC VDC _ COMM INP MODEL INPUT POWER OUTPUT POWER 85 250 VAC 50 60Hz 14VA OPERATING TEMP 0 TO 60 C 12VDC UNREG 400mA 12V...

Страница 6: ... pressing the SEL button with Pro NO displayed This will commit any stored parameter changes to memory and return the meter to the Display Mode If power loss occurs before returning to the Display Mode verify recent parameter changes PROGRAMMING TIPS It is recommended to start with Module 1 and proceed through each module in sequence When programming is complete it is recommended to record the par...

Страница 7: ...ut Values have to be derived from the actual input signal source or simulator the Apply APLY scaling style must be used KEy APLY 0 000 INP 1 INPUT VALUE FOR SCALING POINT 1 For Key in KEY style enter the known first Input Value using the front panel buttons The Input Range selection sets the decimal location for the Input Value For Apply APLY style the meter shows the previously stored Input Value...

Страница 8: ...ow FACTORY SERVICE OPERATIONS yES NO YES NO Enables the Maximum Display Capture capability Enables the Minimum Display Capture capability The CUB5P uses stored calibration values to provide accurate voltage and current measurements Over time the electrical characteristics of the components inside the meter could slowly change therefore the stored calibration values may no longer accurately define ...

Страница 9: ...Backlight Unit Only 3 dSP dSP t SEL rSt ZErO UNItS COLOr CodE Display Intensity Level d LEV ScroL Display Scroll Enable PARAMETER MENU The yES selection allows the SEL button to toggle through the enabled displays FRONT PANEL DISPLAY SELECT ENABLE SEL This selection allows the RST button to reset the selected value s FRONT PANEL RESET ENABLE RST The yES selection allows the display to automaticall...

Страница 10: ...nced are affected by the hysteresis When the setpoint is a control output usually balanced hysteresis is used For alarm applications usually unbalanced hysteresis is used For unbalanced hysteresis modes the hysteresis functions on the low side for high acting setpoints and functions on the high side for low acting setpoints Note Hysteresis eliminates output chatter at the switch point while time d...

Страница 11: ...active when one of the optional serial communications programming cards is installed in the meter Refer to the CUB5COM bulletin for details and setup for the CUB5 RS232 or RS485 serial communications Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements PARAMETER MENU button or user input manual reset serial reset command or meter power cycle When the u...

Страница 12: ...n tOF n rSt n rEn n ChC n Standby Operation Stb n Front Panel Reset Enable Front Panel Display Select Enable Display Update Time dSP t SEL rSt 3 dSP Display Intensity Level COLOr Units Indicator Selection UNItS Display Color d LEV Programming Security Code CodE rANGE dECPt 1 INP FILtr bANd USrIN INP 1 dSP 1 INP 2 U ASN LO En Min Display Enable Max Capture Delay Time Max Display Enable HI En HI t 2...

Отзывы: