OPERATING INSTRUCTIONS

Setup Modes

Pressure Warning Level

Mode / Beeps:  

7

Selections:  

0psi-35psi

Press and hold to slowly increase the pressure reading until it reaches the desired 
warning level.

Relay Output

Mode / Beeps:  

8

Selections:  

‘+’/‘-’ for above/below, pointers/levels

Press and hold the programming button to cycle through which warning will trigger 
the relay output. A number on the display indicates that the Optional Pressure Sensor 
warning will trigger the relay.  A pointer indicates that that reading will trigger the 
relay. After each cycle, under(-) or over(+) pressure mode is selected.

Note: Grey segment denotes a flashing portion of the Gauge screen during this mode of setup.

RECOMMENDED ACCESSORY: ENHANCED LIGHTING CONTROLLER (GA-ELC)

The REDARC Enhanced Lighting Controller is designed to enhance the lighting of your REDARC gauge. It 
is to be used when you do not have a dimming circuit to connect your gauge to or the dimming circuit in 
your vehicle does not dim the REDARC gauge to your liking.

The GA-ELC also allows you to program night time brightness and colour of your REDARC gauges, 
including dimming if connected to a dash dimmer. Once programmed your gauges will change colour 
when turning on your park lights and back to a day light colour when you turn them off.

The GA-ELC is also 24V capable and only one is required for a set of gauges.

Refer to 

www.redarc.com.au

 for more details.

PSI

EGT

X100

PSI

BOOST

3

5

7

4

6

0

10

20

30

7

PSI

EGT

X100

PSI

BOOST

3

5

7

4

6

0

10

20

30

Содержание G52-BEP

Страница 1: ...Optional Oil Pressure Display requires the purchase of GS P 150 EGT Boost Pressure 52mm Gauge with Optional Oil Pressure Display G52 BEP PSI EGT X100 PSI BOOST 3 5 7 4 6 0 10 20 30 G52 BEP G52 BEP...

Страница 2: ...table for installation into marine environments SPECIFICATIONS G52 BEP Input Voltage Range 6 16V For 24V systems use GA 2412V Nominal Current Draw 30mA Gauge Dimensions 52mm x 42mm not incl studs Beze...

Страница 3: ...ure a bare metal on metal connection It is recommended that any wiring harnesses be covered using conduit or similar A steel 1 8 inch NPT bung supplied can be welded into a suitable location on the ex...

Страница 4: ...qualified installer 4 Assemble and Install the compression cap and ferrule assembly onto the welded base and finger tighten Refer to diagram below for correct compression cap assembly 5 Remove the bl...

Страница 5: ...f an instantaneous temperature change Five time constants are required to approach 100 of the step change value Outer Sheath Material Inconel melting point 2550 F 1400 C Cable Stainless steel over bra...

Страница 6: ...gauge switch is only needed to set the programming ID Setup Instructions Setup Mode is only required if you wish to change settings such as background color or other options Setup mode is indicated b...

Страница 7: ...Warning Level Mode Beeps 4 Selections 10psi 30psi Press and hold the programming button until the desired warning pressure is set EGT Warning Level Mode Beeps 5 Selections 400 C 700 C Press and hold...

Страница 8: ...reen during this mode of setup RECOMMENDED ACCESSORY ENHANCED LIGHTING CONTROLLER GA ELC The REDARC Enhanced Lighting Controller is designed to enhance the lighting of your REDARC gauge It is to be us...

Страница 9: ...head impact hazard Should I enclose the wiring harnesses in conduit REDARC recommends enclosing the supplied wiring harnesses in a suitable conduit that will protect the wiring against sharp edges and...

Страница 10: ...purpose for which the Product was manufactured 6 9 any indirect or incidental damage of whatever nature outside the control of Redarc 7 Warranty claims in respect of a Product must be made in writing...

Отзывы: