EGT PROBE INSTALLATION

The EGT Sensor should be installed in the following fashion by a suitably qualified installer:

1. Allow the engine to cool completely before commencing any work.

2. Locate the recommended sensor location point on the pipe. (Each make and model of vehicle will 
have a specific location for the EGT sensors on the factory pipes. For aftermarket pipes, the system 
may require a sensor location which is very different from the factory location - Consult your dealer or 
manufacturer for the correct location for your system)

3. Have the pipe drilled and the included threaded boss welded into the appropriate position by a suitably 
qualified installer.

4. Assemble and Install the compression cap and ferrule assembly onto the welded base and finger 
tighten (Refer to diagram below for correct compression cap assembly)

5. Remove the black protective rubber cap from the end of the sensor probe and insert through the 
installed mounting hardware. Tighten compression nut using an open-end wrench. Do not over tighten - 
typically ½ turn past finger tight is sufficient.

6. If room permits, align the sensor transition and spring at a 90-degree angle to the exhaust pipe to 
position the sensor tip correctly in the exhaust stream.

7. Connect the interface plug wires. (Refer to diagram below) 

Note: yellow wire should be connected to ‘+’, 

red wire to ‘-’

Red

Yellow

3

REDARC also offer a range of different sized muffler clamp 
mounts to suit the EGT Probe.

Refer to 

www.redarc.com.au

 for more details.

Содержание G52-BEP

Страница 1: ...Optional Oil Pressure Display requires the purchase of GS P 150 EGT Boost Pressure 52mm Gauge with Optional Oil Pressure Display G52 BEP PSI EGT X100 PSI BOOST 3 5 7 4 6 0 10 20 30 G52 BEP G52 BEP...

Страница 2: ...table for installation into marine environments SPECIFICATIONS G52 BEP Input Voltage Range 6 16V For 24V systems use GA 2412V Nominal Current Draw 30mA Gauge Dimensions 52mm x 42mm not incl studs Beze...

Страница 3: ...ure a bare metal on metal connection It is recommended that any wiring harnesses be covered using conduit or similar A steel 1 8 inch NPT bung supplied can be welded into a suitable location on the ex...

Страница 4: ...qualified installer 4 Assemble and Install the compression cap and ferrule assembly onto the welded base and finger tighten Refer to diagram below for correct compression cap assembly 5 Remove the bl...

Страница 5: ...f an instantaneous temperature change Five time constants are required to approach 100 of the step change value Outer Sheath Material Inconel melting point 2550 F 1400 C Cable Stainless steel over bra...

Страница 6: ...gauge switch is only needed to set the programming ID Setup Instructions Setup Mode is only required if you wish to change settings such as background color or other options Setup mode is indicated b...

Страница 7: ...Warning Level Mode Beeps 4 Selections 10psi 30psi Press and hold the programming button until the desired warning pressure is set EGT Warning Level Mode Beeps 5 Selections 400 C 700 C Press and hold...

Страница 8: ...reen during this mode of setup RECOMMENDED ACCESSORY ENHANCED LIGHTING CONTROLLER GA ELC The REDARC Enhanced Lighting Controller is designed to enhance the lighting of your REDARC gauge It is to be us...

Страница 9: ...head impact hazard Should I enclose the wiring harnesses in conduit REDARC recommends enclosing the supplied wiring harnesses in a suitable conduit that will protect the wiring against sharp edges and...

Страница 10: ...purpose for which the Product was manufactured 6 9 any indirect or incidental damage of whatever nature outside the control of Redarc 7 Warranty claims in respect of a Product must be made in writing...

Отзывы: