OPERATING INSTRUCTIONS

Selecting Gauge ID for multi-gauge systems

If your gauge is part of a multi gauge system (i.e. more than one gauge) and you wish to allow 
programming from a single push button, connect the communication link wires together (see wiring 
diagram on page 2). The Gauge “Id” of all linked gauges will need to be set to unique numbers.
Make sure that each gauge is set to a unique number or letter and that one gauge is set as the master 
“Id.0”. The master gauge switch needs to be accessible for programming all the gauges. Each individual 
gauge switch is only needed to set the programming ID.

Setup Instructions

Setup Mode is only required if you wish to change settings such as background color or other options. Setup 
mode is indicated by the display of the programming symbol. 
A detailed listing of the Setup Modes for the G52-BEP can be found on page 6. 

To enter Setup Mode:

To view the next setting:

To change the setting & move to next mode:

To save all changes:

*Refer to “Selecting Gauge ID for multi-gauge systems” 

at the top of this page

RELEASE

4

3

To access

all settings

To access

Gauge ID

Only*

2

HOLD

1

LO

CK

ACC O

N

ST

AR

T

OFF

Ignition

OFF

Parklight

OFF

Release to

select

Push & Hold

to Cycle

Push

(Momentary)

5

Push to Cycle

...

LO

CK

ACC O

N

ST

AR

T

OFF

Ignition

OFF

Parklight

OFF

Содержание G52-BEP

Страница 1: ...Optional Oil Pressure Display requires the purchase of GS P 150 EGT Boost Pressure 52mm Gauge with Optional Oil Pressure Display G52 BEP PSI EGT X100 PSI BOOST 3 5 7 4 6 0 10 20 30 G52 BEP G52 BEP...

Страница 2: ...table for installation into marine environments SPECIFICATIONS G52 BEP Input Voltage Range 6 16V For 24V systems use GA 2412V Nominal Current Draw 30mA Gauge Dimensions 52mm x 42mm not incl studs Beze...

Страница 3: ...ure a bare metal on metal connection It is recommended that any wiring harnesses be covered using conduit or similar A steel 1 8 inch NPT bung supplied can be welded into a suitable location on the ex...

Страница 4: ...qualified installer 4 Assemble and Install the compression cap and ferrule assembly onto the welded base and finger tighten Refer to diagram below for correct compression cap assembly 5 Remove the bl...

Страница 5: ...f an instantaneous temperature change Five time constants are required to approach 100 of the step change value Outer Sheath Material Inconel melting point 2550 F 1400 C Cable Stainless steel over bra...

Страница 6: ...gauge switch is only needed to set the programming ID Setup Instructions Setup Mode is only required if you wish to change settings such as background color or other options Setup mode is indicated b...

Страница 7: ...Warning Level Mode Beeps 4 Selections 10psi 30psi Press and hold the programming button until the desired warning pressure is set EGT Warning Level Mode Beeps 5 Selections 400 C 700 C Press and hold...

Страница 8: ...reen during this mode of setup RECOMMENDED ACCESSORY ENHANCED LIGHTING CONTROLLER GA ELC The REDARC Enhanced Lighting Controller is designed to enhance the lighting of your REDARC gauge It is to be us...

Страница 9: ...head impact hazard Should I enclose the wiring harnesses in conduit REDARC recommends enclosing the supplied wiring harnesses in a suitable conduit that will protect the wiring against sharp edges and...

Страница 10: ...purpose for which the Product was manufactured 6 9 any indirect or incidental damage of whatever nature outside the control of Redarc 7 Warranty claims in respect of a Product must be made in writing...

Отзывы: