1 INSTALLATION
1.1
Mounting the BMIS
STEP 1.
Bolt the BMIS to a mounting plate with 4 x M8 anti-vibration fasteners and large flat
washers as shown (Grade 8.8 minimum). Recommended to use 19mm OD, 1.6mm Flat
washer as a minimum size.
TORQUE:
10Nm then 20Nm in a cross pattern (to avoid stressing the housing)
4
ENSURE THAT SWITCH IS OFF BEFORE INSTALLING THE BMIS UNIT (MARKED ‘0’).
ENSURE THAT THE BMIS IS MOUNTED IN THE ORIENTATION AS DEPICTED ON A FLAT PLANE OR USING THE
BMIS-AP. ALTERNATIVE ORIENTATION MAY COMPROMISE CORRECT PRODUCT FUNCTION.
DO NOT ATTEMPT TO OPEN THE UNIT BY REMOVING THE REAR COVER. THIS UNIT IS NOT SERVICEABLE.
Содержание BMIS series
Страница 1: ...Battery Master Isolation Switch BMIS 4PN BMIS 4PP...
Страница 18: ...17 8 NOTES...