Pub. 42004-545A
telephone VoIP WiFi Telephone Manual
Page 20 of 29
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-545A.docx
03/20
12.
Click the
R
ESTART
button, located in the
R
ESTART
M
ODULE
section.
•
The web page will show
R
EBOOTING
…
while the WiFi module is restarting.
•
Both LEDs on the RJ-45 Jack
J2
will turn OFF for several seconds while the WiFi interface
restarts.
•
The green LED turns ON first; after the WiFi interface restarts.
•
The yellow LED turns ON when the WiFi interface connects to the newly configured network.
13.
Continue with the configuration of the VoIP telephone PCBA (see the VoIP Telephone Setup
section).
14.
If an incorrect WEP Key or Pass Phrase is entered:
Follow the instructions in the next section (see
the Reset WiFi Interface Configuration section).
N
OTE
:
The WiFi module is no longer an access point on its own network (HF-A11x_AP). The WiFi
module should now be connected to or trying to connect to the newly configured wireless
network. The browser web page will not change from showing
R
EBOOTING
…
because the PC is
no longer connected to the HF-A11x_AP network.
Reset WiFi Interface Configuration
Use this procedure to erase the current wireless network configuration in the telephone and configure the
telephone’s wireless adapter with the factory default settings:
1.
Press and hold the
RLOAD
button for 10 seconds.
•
The RLOAD pushbutton is located on the WiFi adapter near the Ethernet jack
J2
.
•
Both LEDs on the RJ-45 jack (
J2
) turn OFF for several seconds while the WiFi interface resets.
•
Wait for the green LED to turn ON before trying to connect to the HF-A11x_AP network.
2.
Follow the instructions in the First Time WiFi Interface Setup section to connect to the HF-A11x_AP
network and configure the wireless network settings.
N
OTE
:
The telephone’s power must be cycled before it will connect to the wireless network after
changing the WiFi interface configuration if the VoIP telephone was configured for DHCP.
VoIP Telephone Setup
1.
Connect a PC to the same network as the VoIP telephone.
2.
Log into the unit’s web interface.
The unit is factory configured with a static IP address:
192.168.1.2.
3.
Enter the username and password when prompted.
The initial factory settings are:
•
U
SER
N
AME
:
user
•
P
ASSWORD
:
password
4.
Change the username and password upon first login.
This security measure helps prevent unauthorized changes to the VoIP telephone’s interface
configuration.