Pub. 42004-545A
telephone VoIP WiFi Telephone Manual
Page 11 of 29
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-545A.docx
03/20
Model 397-81
x
A and 398-81
x
A Telephones (Flush-Mount Applications)
Figure 10. Model 397-810A
Figure 11. Model 397-811A
1.
Use the supplied back box to mount the Model 397-810A, 397-811A, 398-811A and 398-812A VoIP
WiFi telephones in flush-mount applications or in a GAI-Tronics Model 234 Series Communication
Station. Mount the back box to the structure using the appropriate hardware (see Figure 15).
N
OTES
:
•
When installing a RED ALERT flush-mount VoIP telephone in a GAI-Tronics 236-00
x
Series or
238-001 Surface-Mount Enclosure, the front panel assembly mounts directly to the enclosure
(back box is not required.)
•
When mounting outdoors, the installation of a (customer-supplied) surge suppressor on the power
line is recommended.
2.
Remove the tapered plug from the one of the rear cable entry holes in the back box and install the
power and antenna cable and cable fitting (see the Field Wiring section on page 14).
3.
Connect all peripheral devices (see the Auxiliary I/O section).
4.
Perform the initial programming of the telephone (see the Programming section on Page 17).
5.
Verify operation by calling to and from another telephone.
6.
Attach the telephone’s front panel to the mounting flanges of the back box using the six supplied
#10-32 security screws and washers.
7.
Torque the screws to 10–12 in·lb.