12 - TROUBLESHOOTING
CHECKING THE INTERNAL COMPONENTS
ATTENTION:
All operations that require repairs must be carried out solely by a specialist technician with the boiler extinguished,
cold and with the power cord unplugged.
ANOMALY
POSSIBLE CAUSES
SOLUTIONS
The pellets are not fed into the
combustion chamber.
The pellet hopper is empty
Fill the hopper with pellets
Sawdust has blocked the feed screw
Empty the hopper and remove the sawdust
from the feed screw by hand
Faulty gear motor
Replace the gear motor
Faulty electronic board
Replace the circuit board
The fire goes out or the boiler stops
automatically.
The pellet hopper is empty
Fill the hopper with pellets
The pellets are not fed
See the previous anomaly
The pellet temperature safety probe has
been triggered
Let the boiler cool down, restore
the thermostat until the problem is
resolved and switch the boiler back on.
If the problem persists contact Technical
Assistance.
The door is not closed properly or the
gaskets are worn
Close the door and replace the gaskets
with original ones
Unsuitable pellets
Change the type of pellets with those
recommended by the manufacturer
Low pellet supply
Check the flow of fuel following the
instructions in the booklet.
The combustion chamber is dirty
Clean the combustion chamber, following
instructions in the manual
Clogged outlet
Clean the smoke duct
Faulty smoke extraction motor
Check the motor and replace it, if neces-
sary
Pressure switch broken or defective.
Replace the pressure switch.