26
10 - SAFETY DEVICES AND ALARMS
ALARM SIGNALLING
When a condition occurs other than the one expected for regular operation of the boiler, an alarm is triggered.
The reason for the alarm is given on the control panel. The sound signal is not enabled for alarms A01-A02 in order not to disturb the user
when there is an absence of pellets in the night tank.
Panel signalling
type of problem
Solution
A01
The fire does not ignite.
Check the level of pellets in the tank.
A02
Flame extinction.
Check the level of pellets in the tank.
A03
Pellet thermostat alarm
The temperature of the pellet duct exceeds the
required safety threshold.
Wait until the end of the cooling phase, stop the
alarm and re-ignite the boiler setting the supply of
fuel to minimum (SETTINGS menu - pellet recipe). If
the alarm persists, contact the service centre.
A04
Smoke overtemperature
The set smoke threshold has been exceeded. Reduce
the load of pellets (SETTINGS menu - Pellet recipe).
A05
Water pressure gauge
alarm
Insufficient water pressure.
Check the pressure of the hydraulic system.
Load the system.
A06
Smoke pressure gauge
alarm
Smoke pressure gauge intervention
Check for obstruction in chimney.
A07
Ash drawer not installed correctly.
Check the ash drawer; if the problem persists call the
assistance centre.
A08
Smoke aspirator broken
alarm
Anomalous operation of smoke fan.
Delete the alarm and switch the boiler on again. If the
alarm persists, contact the service centre.
A09
Fault with the smoke sensor.
Delete the alarm and switch the boiler on again. If the
alarm persists, contact the service centre.
A10
Grate not closed
Clean and switch the boiler on again. If the alarm
persists, contact the service centre.
A11
Auger alarm
Fault with supply of auger or anomalous
loading.
Auger working continuously or faulty printed circuit
board. Call the assistance centre.
A13
Intervention of H
2
O safety
thermostat
H
2
O thermal safety device
This alarm is triggered when the water in the
system does not circulate and the temperature
increases as a result.
Check and release the pump if necessary. Contact the
assistance centre if necessary to have the component
replaced.
A18
Water overtemperature
alarm
Water tank temperature too high.
This alarm is triggered when the water in the
system does not circulate and the temperature
increases as a result.
Check and release the pump if necessary. Call the
assistance centre to have the component replaced.
A19
Water sensor alarm
Fault with water sensor.
Water sensor detached / interrupted / defective / not
recognised.
Call the assistance centre.